Slope Correcting Anterior Closing Wedge Tibial Osteotomy Using Patient-Specific Instrumentation in Setting of Multiple Previous Revision ACL Reconstructions.
- 1Department of Orthopedics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
Abstract
Background
Graft failure after anterior cruciate ligament (ACL) reconstruction (ACLR) is a rare but devastating complication that is often multifactorial. Increased posterior tibial slope (PTS) is a known risk factor for graft failure after ACLR. Anterior closing wedge high tibial osteotomy (ACW-HTO) has been shown to reliably correct PTS and improve knee stability.Indications
In patients with failed ACLR and PTS ≥12°, ACW-HTO for posterior slope correction may be indicated.Technique description
The presented technique demonstrates an ACW-HTO in a female Division I athlete with 2 previous ACLRs and recurrent graft failure. Patient-specific instrumentation (PSI) planning software is used to develop a 3-dimensional-printed cutting guide for HTO and a proximal tibia plate guide to aid in precise slope correction. An ACW-HTO is performed from the anteromedial aspect of the proximal tibia utilizing the premade cutting guide and a posterior hinge pin. A 6-hole patient-specific proximal tibia plate is then applied, taking care to avoid potential future ACLR tibial tunnel trajectory.Results
Previous studies have demonstrated a low graft failure rate, improved patient outcomes, and highly variable return-to-sport rates after slope-corrected osteotomy in the setting of ACL insufficiency. Improved posterior tibial slope decreases rates of subsequent ACL graft failure and, in some cases, may obviate the need for revision ACLR because of subjective improvement in knee stability.Discussion/conclusion
This surgical technique video demonstrates a reliable, reproducible method of PTS correction in the setting of multiple failed ACLRs with recurrent graft failure. Technique modifications and the addition of concomitant procedures to ACLR are increasing in popularity to reduce rerupture rates and improve patient outcomes. ACW-HTO for slope correction is a powerful tool that should be considered in select patients with ACL injuries and increased posterior tibial slope.Patient consent disclosure statement
The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
Related
- Current Reviews in Musculoskeletal Medicine Innovative Techniques in Knee Preservation: Osteotomy about the Knee: The Advent of Patient Specific Instrumentation (PSI)
- Bibliometric analysis of slope-correcting osteotomy in the context of anterior cruciate ligament reconstruction: key trends, contributors and themes
- Patient-Specific Instrumentation for Medial Opening Wedge High Tibial Osteotomy With Concomitant Medial Meniscal Root Repair
- Comparative Analysis between Vertebral Body Sliding Osteotomy and Anterior Cervical Corpectomy with Fusion for Cervical Spinal Ossification of Posterior Longitudinal Ligament
- Effects of vertebral shortening during corrective osteotomy for spinal deformity on spinal cord biomechanics and cerebrospinal fluid-anterior spinal artery fluid-structure interaction
BibTeX
@article{hop2026slope,
title = {{Slope Correcting Anterior Closing Wedge Tibial Osteotomy Using Patient-Specific Instrumentation in Setting of Multiple Previous Revision ACL Reconstructions.}},
author = {Jack C Hop and Benjamin R Wharton and Evan H Richman and Jillian Shae and Kevin Shinsako and Katrina Schantz and Rachel M Frank},
journal = {Video journal of sports medicine},
year = {2026},
month = sep,
doi = {10.1177/26350254261466714},
url = {https://europepmc.org/article/MED/43048060},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Slope Correcting Anterior Closing Wedge Tibial Osteotomy Using Patient-Specific Instrumentation in Setting of Multiple Previous Revision ACL Reconstructions.
AU - Jack C Hop
AU - Benjamin R Wharton
AU - Evan H Richman
AU - Jillian Shae
AU - Kevin Shinsako
AU - Katrina Schantz
AU - Rachel M Frank
PY - 2026
DA - 2026/09/01
JO - Video journal of sports medicine
DO - 10.1177/26350254261466714
UR - https://europepmc.org/article/MED/43048060
AB - Background Graft failure after anterior cruciate ligament (ACL) reconstruction (ACLR) is a rare but devastating complication that is often multifactorial. Increased posterior tibial slope (PTS) is a known risk factor for graft failure after ACLR. Anterior closing wedge high tibial osteotomy (ACW-HTO) has been shown to reliably correct PTS and improve knee stability.Indications In patients with failed ACLR and PTS ≥12°, ACW-HTO for posterior slope correction may be indicated.Technique description The presented technique demonstrates an ACW-HTO in a female Division I athlete with 2 previous ACLRs and recurrent graft failure. Patient-specific instrumentation (PSI) planning software is used to develop a 3-dimensional-printed cutting guide for HTO and a proximal tibia plate guide to aid in precise slope correction. An ACW-HTO is performed from the anteromedial aspect of the proximal tibia utilizing the premade cutting guide and a posterior hinge pin. A 6-hole patient-specific proximal tibia plate is then applied, taking care to avoid potential future ACLR tibial tunnel trajectory.Results Previous studies have demonstrated a low graft failure rate, improved patient outcomes, and highly variable return-to-sport rates after slope-corrected osteotomy in the setting of ACL insufficiency. Improved posterior tibial slope decreases rates of subsequent ACL graft failure and, in some cases, may obviate the need for revision ACLR because of subjective improvement in knee stability.Discussion/conclusion This surgical technique video demonstrates a reliable, reproducible method of PTS correction in the setting of multiple failed ACLRs with recurrent graft failure. Technique modifications and the addition of concomitant procedures to ACLR are increasing in popularity to reduce rerupture rates and improve patient outcomes. ACW-HTO for slope correction is a powerful tool that should be considered in select patients with ACL injuries and increased posterior tibial slope.Patient consent disclosure statement The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
SN - 2635-0254
ER -