Analysis of porphyrins from serum and the benefit of inert biphenyl columns for liquid chromatography separation
- 1Service Unit Proteomics, Medical Faculty, University of Münster, Münster, Germany
- 2Clinical Laboratory, University Clinic Münster, Münster, Germany
- 3Department of Neurosurgery, University Clinic Münster, Münster, Germany
Abstract
Reversed-phase liquid chromatography (LC) is a major separation technique for porphyrins. We coupled C18-based LC with mass spectrometry (MS) for the detection of protoporphyrin IX (PPIX) in the context of neurosurgery, where it is used as a fluorescence marker for tumor visualisation. Here, we demonstrate advantages of the replacement of the C18 with an inert biphenyl (iBP) column, which improved separation resolution and increased detection sensitivity in LC-MS of six porphyrins (uroporphyrin I, hepta-, hexa-, and pentacarboxyporphyrin I, coproporphyrins I and III) associated with the heme biosynthesis pathway. They are of potential interest as intermediates and side products in our research on 5-aminolevulinic acid-induced fluorescence-guided neurosurgery. Porphyrins consist of conjugated π-systems which interact with aromatic stationary phases such as BP by taking advantage of π-π stacking interactions. Carryover observed with PPIX on endcapped C18 stationary phase was reduced. This improvement was due to the reduction of non-specific adsorption on metallic surfaces from the LC instrument by using inert column hardware combined with the BP stationary phase. Passivation by chemical vapor deposition was shown to reduce non-specific adsorption in the LC system better than methods using mobile phase additives. PEEK tubing in conjunction with the iBP-column provided the best results and shortened run time. Furthermore, we present a Python-based software tool for automated data processing and analyte quantification. This work contributes to our ongoing developments of porphyrin LC-MS in blood and tissue samples from glioma patients.
Related
- Microfluidic sperm separation for intracytoplasmic sperm injection yields similar blastocyst rates compared with density gradient, however, may be of benefit for male factor infertility: a randomized sibling oocyte study.
- The biphenyl dimeric compound 3,3’,5,5’-tetramethoxybiphenyl-4,4’-diol disrupts redox homeostasis and mitochondrial function to inhibit growth and induce apoptosis in breast cancer monolayers and 3D tumor spheroids
- Finite element analysis of the mechanical behavior of stiffened cold-formed built-up CFST flat columns
- Detection of Carbapenemase-Producing Bacteria by Using an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method
- High-Performance Liquid Chromatography-Ultraviolet Detection and Gas Chromatography-Mass Spectrometry Analyses of Bioactive Compounds of Urtica dioica Leaf Extracts Using Various Solvents
BibTeX
@article{unnerstall2026analysis,
title = {{Analysis of porphyrins from serum and the benefit of inert biphenyl columns for liquid chromatography separation}},
author = {Moritz Unnerstall and Manfred Fobker and Patrick Christian Opitz and Lukas Helmer and Eric Suero Molina and Simone König},
journal = {PLOS One},
year = {2026},
month = sep,
doi = {10.1371/journal.pone.0357115},
url = {https://doi.org/10.1371/journal.pone.0357115},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Analysis of porphyrins from serum and the benefit of inert biphenyl columns for liquid chromatography separation
AU - Moritz Unnerstall
AU - Manfred Fobker
AU - Patrick Christian Opitz
AU - Lukas Helmer
AU - Eric Suero Molina
AU - Simone König
PY - 2026
DA - 2026/09/15
JO - PLOS One
DO - 10.1371/journal.pone.0357115
UR - https://doi.org/10.1371/journal.pone.0357115
AB - Reversed-phase liquid chromatography (LC) is a major separation technique for porphyrins. We coupled C18-based LC with mass spectrometry (MS) for the detection of protoporphyrin IX (PPIX) in the context of neurosurgery, where it is used as a fluorescence marker for tumor visualisation. Here, we demonstrate advantages of the replacement of the C18 with an inert biphenyl (iBP) column, which improved separation resolution and increased detection sensitivity in LC-MS of six porphyrins (uroporphyrin I, hepta-, hexa-, and pentacarboxyporphyrin I, coproporphyrins I and III) associated with the heme biosynthesis pathway. They are of potential interest as intermediates and side products in our research on 5-aminolevulinic acid-induced fluorescence-guided neurosurgery. Porphyrins consist of conjugated π-systems which interact with aromatic stationary phases such as BP by taking advantage of π-π stacking interactions. Carryover observed with PPIX on endcapped C18 stationary phase was reduced. This improvement was due to the reduction of non-specific adsorption on metallic surfaces from the LC instrument by using inert column hardware combined with the BP stationary phase. Passivation by chemical vapor deposition was shown to reduce non-specific adsorption in the LC system better than methods using mobile phase additives. PEEK tubing in conjunction with the iBP-column provided the best results and shortened run time. Furthermore, we present a Python-based software tool for automated data processing and analyte quantification. This work contributes to our ongoing developments of porphyrin LC-MS in blood and tissue samples from glioma patients.
SN - 1932-6203
ER -