Additively Manufactured in planta Integrated Microneedle–Microfluidic Sensing: Nondestructive Electrochemical Tracking of Glucose and Water Stress in Agricultural Crop Plants
- 1Virginia Tech , , , ,
Abstract
Timely quantification of crop stress physiology remains challenging because conventional assays are destructive, labor-intensive, and poorly suited for continuous monitoring and field deployment. Here, we report a microneedle-enabled electrochemical biosensing platform with smartphone-based data collection for the in planta monitoring of plant stress that integrates three design innovations in a single architecture: (i) a fully integrated hollow microneedle-microfluidic measurement pathway for sap access, (ii) physical isolation of the metal electrodes from direct tissue contact to reduce insertion-zone abrasion of the sensing interface, improving biocompatibility and potentially lowering fouling pathways, and (iii) lithography-free fabrication of a modular transducer on an additively manufactured substrate. The platform comprises a three-electrode gold (Au) transducer modified with a nanostructured reduced graphene oxide (rGO)-chitosan layer. The biosensing platform enabled dual sensing channels via functionalized glucose oxidase (GOx) and horseradish peroxidase (HRP) for the detection of glucose and water stress-associated hydrogen peroxide (H2O2), respectively. The glucose channel showed a strong linear calibration over the tested range, with Pearson's r = 0.99, R2 = 0.98, sensitivity of 62.34 μA/mM, and a limit of detection (LOD) of 102.50 μM (∼1.85 mg/dL), while the H2O2 channel exhibited Pearson's r = 0.99, R2 = 0.99, sensitivity of 3.65 μA/decade, and an LOD of 3.22 μM. Repeatability across measured standards remained high for both channels, with mean coefficients of variation of 1.31% for glucose and 1.16% for H2O2. Ex vivo measurements in plant sap, including standard-addition experiments and comparison with commercial benchmark assays, provided validation of analyte concentration determination in plant-derived samples. In planta measurements on maize plants (Zea mays L.) grown under graded watering treatments revealed statistically significant treatment-dependent glucose and H2O2 signatures over time (p < 0.05), consistent with carbon-status and oxidative-stress responses to water deficit, respectively. This integrated, manufacturable platform provides a practical route toward real-time, data-driven crop management using minimally invasive electrochemical readouts.
Related
- Laser-Induced Graphene Paper-Based Microfluidic Platform for Dual-Mode Electrochemical and Colorimetric Detection of Glucose
- Ground-State Charge Generation-Enabled Nondestructive Defect Passivation in Organic Photovoltaics.
- A Nondestructive Method to Quantify Polymer Graft Density on Nanoparticles Using Optical Extinction Spectra.
- SMART SENTINEL: Nondestructive Point-of-Need CRISPR-Cas12a Lateral Flow Platform for Rapid New World Screwworm Field Triage
- Passivation properties of ultrafine grain 316L stainless steels manufactured by ball milling and spark plasma sintering
BibTeX
@article{erukainure2026additively,
title = {{Additively Manufactured in planta Integrated Microneedle–Microfluidic Sensing: Nondestructive Electrochemical Tracking of Glucose and Water Stress in Agricultural Crop Plants}},
author = {Frank Efe Erukainure and Blake N. Johnson and David B. Langston and Abhilash Kumar Chandel},
journal = {ACS Sensors},
year = {2026},
month = jul,
doi = {10.1021/acssensors.6c01122},
url = {https://doi.org/10.1021/acssensors.6c01122},
note = {CC BY},
}
RIS
TY - JOUR
TI - Additively Manufactured in planta Integrated Microneedle–Microfluidic Sensing: Nondestructive Electrochemical Tracking of Glucose and Water Stress in Agricultural Crop Plants
AU - Frank Efe Erukainure
AU - Blake N. Johnson
AU - David B. Langston
AU - Abhilash Kumar Chandel
PY - 2026
DA - 2026/07/02
JO - ACS Sensors
DO - 10.1021/acssensors.6c01122
UR - https://doi.org/10.1021/acssensors.6c01122
AB - Timely quantification of crop stress physiology remains challenging because conventional assays are destructive, labor-intensive, and poorly suited for continuous monitoring and field deployment. Here, we report a microneedle-enabled electrochemical biosensing platform with smartphone-based data collection for the in planta monitoring of plant stress that integrates three design innovations in a single architecture: (i) a fully integrated hollow microneedle-microfluidic measurement pathway for sap access, (ii) physical isolation of the metal electrodes from direct tissue contact to reduce insertion-zone abrasion of the sensing interface, improving biocompatibility and potentially lowering fouling pathways, and (iii) lithography-free fabrication of a modular transducer on an additively manufactured substrate. The platform comprises a three-electrode gold (Au) transducer modified with a nanostructured reduced graphene oxide (rGO)-chitosan layer. The biosensing platform enabled dual sensing channels via functionalized glucose oxidase (GOx) and horseradish peroxidase (HRP) for the detection of glucose and water stress-associated hydrogen peroxide (H2O2), respectively. The glucose channel showed a strong linear calibration over the tested range, with Pearson's r = 0.99, R2 = 0.98, sensitivity of 62.34 μA/mM, and a limit of detection (LOD) of 102.50 μM (∼1.85 mg/dL), while the H2O2 channel exhibited Pearson's r = 0.99, R2 = 0.99, sensitivity of 3.65 μA/decade, and an LOD of 3.22 μM. Repeatability across measured standards remained high for both channels, with mean coefficients of variation of 1.31% for glucose and 1.16% for H2O2. Ex vivo measurements in plant sap, including standard-addition experiments and comparison with commercial benchmark assays, provided validation of analyte concentration determination in plant-derived samples. In planta measurements on maize plants (Zea mays L.) grown under graded watering treatments revealed statistically significant treatment-dependent glucose and H2O2 signatures over time (p < 0.05), consistent with carbon-status and oxidative-stress responses to water deficit, respectively. This integrated, manufacturable platform provides a practical route toward real-time, data-driven crop management using minimally invasive electrochemical readouts.
SN - 2379-3694
ER -