A novel hydrophobic deep eutectic solvent-based paired-drop microextraction method for the trace determination of metribuzin in urine samples
- 1Health and Environment Research Center, Zanjan University of Medical Sciences (ZUMS)
- 2Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences (TUMS)
Abstract
A hydrophobic deep eutectic solvent (DES) was molecularly tailored from tributylphosphine oxide and octanoic acid via hydrogen-bonding and employed as an efficient extractant in a novel ultrasound-assisted paired-drop microextraction (UAE-PDME) method for metribuzin determination in urine. The DES structure was confirmed by FTIR analysis. The innovative paired-drop design addresses a key practical challenge: while ultrasound efficiently disperses the extractant, quantitatively retrieving a minute volume (e.g., 2 µL) of dispersed solvent from an aqueous sample is nearly impossible. This method solves this by using a second, hanging DES droplet that coalesces with the dispersed microdroplets during gentle stirring, enabling efficient, complete, and centrifugation-free collection of the enriched phase. After optimization of key parameters, the method was rigorously validated using spiked urine samples. It demonstrated excellent performance: a wide linear range of 5–500 µg/L, low limits of detection and quantification of 0.20 and 0.67 µg/L, respectively, high precision (RSD < 3.6%), quantitative recoveries (99.5–103.1%) with negligible matrix effect (− 4.2%) and high solvent phase recovery (98.5%). The high extraction efficiency is attributed to the DES’s rational molecular design. The DES-UAE-PDME method represents a green, rational, and effective sample preparation strategy for trace pesticide monitoring using conventional HPLC–UV instrumentation.
Related
- Magnetically retrievable natural deep eutectic solvent-based ferrofluid for green microextraction of gemfibrozil from human plasma
- Comprehensive Study of L-Menthol and Octanoic Acid as a Hydrophobic Eutectic Solvent
- Unveiling the Molecular Driving Forces of Pollutant Extraction by Hydrophobic Eutectic Solvents.
- Cellulose-supported MIL-101(Fe)/g-C3N4 as a sustainable and efficient sorbent for thin film microextraction of organophosphorus pesticides followed by determination through HPLC-UV
- Green electropolishing of pure titanium using a choline chloride–lactic acid deep eutectic solvent
BibTeX
@article{pourhossein2026novel,
title = {{A novel hydrophobic deep eutectic solvent-based paired-drop microextraction method for the trace determination of metribuzin in urine samples}},
author = {Mehran Pourhossein and Seyed Jamaleddin Shahtaheri},
journal = {Scientific Reports},
year = {2026},
month = jul,
doi = {10.1038/s41598-026-61712-2},
url = {https://doi.org/10.1038/s41598-026-61712-2},
note = {CC BY},
}
RIS
TY - JOUR
TI - A novel hydrophobic deep eutectic solvent-based paired-drop microextraction method for the trace determination of metribuzin in urine samples
AU - Mehran Pourhossein
AU - Seyed Jamaleddin Shahtaheri
PY - 2026
DA - 2026/07/01
JO - Scientific Reports
DO - 10.1038/s41598-026-61712-2
UR - https://doi.org/10.1038/s41598-026-61712-2
AB - A hydrophobic deep eutectic solvent (DES) was molecularly tailored from tributylphosphine oxide and octanoic acid via hydrogen-bonding and employed as an efficient extractant in a novel ultrasound-assisted paired-drop microextraction (UAE-PDME) method for metribuzin determination in urine. The DES structure was confirmed by FTIR analysis. The innovative paired-drop design addresses a key practical challenge: while ultrasound efficiently disperses the extractant, quantitatively retrieving a minute volume (e.g., 2 µL) of dispersed solvent from an aqueous sample is nearly impossible. This method solves this by using a second, hanging DES droplet that coalesces with the dispersed microdroplets during gentle stirring, enabling efficient, complete, and centrifugation-free collection of the enriched phase. After optimization of key parameters, the method was rigorously validated using spiked urine samples. It demonstrated excellent performance: a wide linear range of 5–500 µg/L, low limits of detection and quantification of 0.20 and 0.67 µg/L, respectively, high precision (RSD < 3.6%), quantitative recoveries (99.5–103.1%) with negligible matrix effect (− 4.2%) and high solvent phase recovery (98.5%). The high extraction efficiency is attributed to the DES’s rational molecular design. The DES-UAE-PDME method represents a green, rational, and effective sample preparation strategy for trace pesticide monitoring using conventional HPLC–UV instrumentation.
SN - 2045-2322
ER -