Skip to content
DraconiticResearch
Search Sources API
189,280 studies31 sourcesUpdated 15 min ago
PreprintCC BYChemRxiv

Methodology for Fabricating and Testing Carbon Molecular Sieve (CMS) Dense Film Membranes for Reproducible Permeation Experiments

Abstract

Carbon molecular sieve (CMS) membranes are promising for demanding gas separations, but their brittleness after pyrolysis makes dense-film permeation testing difficult and often irreproducible. Membranes that appear defect-free after pyrolysis can crack during handling, masking, permeation cell assembly, vacuum evacuation or gas pressurization. This work presents a practical procedure for fabricating and testing CMS dense films prepared from fluorinated polyimide-based CMS membranes. We investigated several experimental factors such as polymer concentration, membrane casting in glove bag, epoxy selection, filter paper support, masking and pressure loading, and their resulting impact on the mechanical stability of the membranes Careful control of these steps reduced or entirely mitigated film cracking, gas bypass during testing, and epoxy seal failure during permeation measurements. This study provides a reliable method for casting, masking and testing of fragile CMS dense film membranes and addresses practical details that are often not reported, but are important for successful and reproducible gas permeation data with CMS membranes.

Related

  1. Accuracy, Reliability, and Efficiency of a MACE Machine-Learning Interatomic Potential for Aspirin: A Reproducible Benchmark for Molecular Simulation
    Modupe A. Omoniyi
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  2. Direct separation of intra- and inter-molecular contributions in pulse dipolar EPR experiments
    Olga Vojtiskova, Laura Galazzo, Maxim Yulikov
    arXivPreprintCC BY 4.0Full textPhysical chemistryarXiv
  3. RaX-DT: An Open-Source Platform for Automated Molecular Docking Workflows and Reproducible Pipeline Validation
    Amir Hosein Ghavi, Bita Barazandeh Shirvan, Zohre Ganji +9
    ChemRxivPreprintCC BYFull textGeneral chemistryChemRxiv
  4. Solution-Shearing Self-Assembly of Hydrothermally Synthesized Tellurium Nanowires for Fabricating Field-Effect Transistors with Wafer-Scale Uniformity
    Hao Yang, Mose Park, Yanjin Tang +4
    Nanomaterials (Basel, Switzerland)Peer-reviewedCC BYFull textMaterials & polymersEurope PMCCrossref
  5. Synthesis of halide perovskite thin films from an eutectic mixture of Pb(NO₃)₂, acetamide, and urea for fabricating resistive random-access memory (RRAM).
    Chuong Thanh Huynh, Vy Thao Ha Cao, Tai Duy Nguyen +5
    RSC advancesPeer-reviewedCC BY-NCFull textGeneral chemistryEurope PMC
BibTeX
@misc{roy2026methodology,
  title = {{Methodology for Fabricating and Testing Carbon Molecular Sieve (CMS) Dense Film Membranes for Reproducible Permeation Experiments}},
  author = {Deepanjali Roy and Nhan H. Khuu and Aidan Ghee and Oishi Sanyal},
  howpublished = {ChemRxiv},
  year = {2026},
  month = oct,
  doi = {10.26434/chemrxiv.15010531/v1},
  url = {https://chemrxiv.org/doi/full/10.26434/chemrxiv.15010531/v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Methodology for Fabricating and Testing Carbon Molecular Sieve (CMS) Dense Film Membranes for Reproducible Permeation Experiments
AU  - Deepanjali Roy
AU  - Nhan H. Khuu
AU  - Aidan Ghee
AU  - Oishi Sanyal
PY  - 2026
DA  - 2026/10/15
PB  - ChemRxiv
DO  - 10.26434/chemrxiv.15010531/v1
UR  - https://chemrxiv.org/doi/full/10.26434/chemrxiv.15010531/v1
AB  - Carbon molecular sieve (CMS) membranes are promising for demanding gas separations, but their brittleness after pyrolysis makes dense-film permeation testing difficult and often irreproducible. Membranes that appear defect-free after pyrolysis can crack during handling, masking, permeation cell assembly, vacuum evacuation or gas pressurization. This work presents a practical procedure for fabricating and testing CMS dense films prepared from fluorinated polyimide-based CMS membranes. We investigated several experimental factors such as polymer concentration, membrane casting in glove bag, epoxy selection, filter paper support, masking and pressure loading, and their resulting impact on the mechanical stability of the membranes Careful control of these steps reduced or entirely mitigated film cracking, gas bypass during testing, and epoxy seal failure during permeation measurements. This study provides a reliable method for casting, masking and testing of fragile CMS dense film membranes and addresses practical details that are often not reported, but are important for successful and reproducible gas permeation data with CMS membranes.
ER  -