Skip to content
DraconiticResearch
Search Sources API
190,851 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BY-NC-SAJournal of Medical Physics

Dosimetric Impact of Simultaneous and Separate Planning with Fixed/Iris Collimators on Brain Doses in Multiple Brain Metastases

Abstract

Background: CyberKnife® stereotactic radiosurgery enables frameless, image-guided treatment of multiple brain metastases. Collimator type (Fixed vs. Iris) and planning strategy (Simultaneous vs. Separate) may influence low-dose normal brain exposure, plan quality, and treatment delivery efficiency. Objectives: The objective of the study was to compare the dosimetric performance of different collimator types and planning strategies in patients with three or four brain metastases under standardized planning conditions. Materials and Methods: Twenty patients were retrospectively replanned using four treatment configurations: Fixed Separate, Fixed Simultaneous, Iris Separate, and Iris Simultaneous. All plans were generated using identical prescription doses and planning objectives. Dosimetric evaluation included normal brain V8, V10, V12 (volumes receiving ≥8 Gy, ≥10 Gy, and ≥12 Gy), mean brain dose (Vmean), Paddick conformity index (PCI), and gradient index (GI). Comparisons were performed using Friedman and Wilcoxon signed-rank tests. Estimated treatment time was recorded for all plans. Results: Significant differences were observed for V8 (P = 0.039), Vmean (P = 0.019), and PCI (P < 0.001), whereas V10 (P = 0.180), V12 (P = 0.103), and GI (P = 0.420) showed no significant differences among the planning approaches. Median dosimetric values tended to favor Iris Simultaneous planning for reducing low-dose normal brain exposure. The significant PCI difference was primarily attributable to lower conformity in the Iris Separate plans. Total planning target volume demonstrated a near-significant positive association with V12 (P = 0.057). Iris-based plans were associated with shorter estimated treatment times. Conclusion: Under standardized planning conditions, Iris Simultaneous planning demonstrated favorable trends in reducing low-dose normal brain exposure while improving treatment delivery efficiency. Although conformity differed significantly among planning approaches, mainly because of lower PCI values in the Iris Separate plans, dose gradient characteristics remained comparable. These findings suggest that planning strategy may influence conformity more than dose fall-off in CyberKnife treatment of multiple brain metastases. Nevertheless, given the limited sample size, these results should be interpreted cautiously and validated in larger prospective studies.

Related

  1. Fictive Field-based Feathering for Extended-SSD Total Body Irradiation: A Single-institution Planning and Dosimetric Analysis
    Vijay Kumar Mogulagani, Mohan Raj Uthiran, Ben Johnson Varghese +3
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  2. Dosimetric Outcomes of Definitive Radiation Therapy to Anal Squamous Cell Carcinoma in a Single Institution Using Volumetric Modulated Arc Therapy Evaluated Against Australian and International Treatment Planning Guidelines
    Faisal Alshamrani, Michael Hsieh, Anthony Karl +7
    Journal of Medical Radiation SciencesPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMCEurope PMCPMC
  3. Loss Factor of Axisymmetric and Rectangular Tapered Collimators from Optical to Inductive Regimes
    Md Wahidur Rahman, Alexei Blednykh, Gang Wang +1
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  4. High-purity fluorescence photon bundle emission from two separate emitters
    Zhicai Chen, Jun Xu, Deyi Kong +2
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  5. The separate universe approach with non minimal coupling to gravity
    Hugo Holland, Julien Grain
    HALPreprintCC BY 4.0Full textCosmologyGravitation & general relativityHALarXiv
BibTeX
@article{tataroglu2026dosimetric,
  title = {{Dosimetric Impact of Simultaneous and Separate Planning with Fixed/Iris Collimators on Brain Doses in Multiple Brain Metastases}},
  author = {Hatice Tataroglu and Ela Delikgöz Soykut and Mustafa Özer and Seher Pirzirenli},
  journal = {Journal of Medical Physics},
  year = {2026},
  month = jul,
  doi = {10.4103/jmp.jmp_11_26},
  url = {https://doi.org/10.4103/jmp.jmp_11_26},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Dosimetric Impact of Simultaneous and Separate Planning with Fixed/Iris Collimators on Brain Doses in Multiple Brain Metastases
AU  - Hatice Tataroglu
AU  - Ela Delikgöz Soykut
AU  - Mustafa Özer
AU  - Seher Pirzirenli
PY  - 2026
DA  - 2026/07/01
JO  - Journal of Medical Physics
DO  - 10.4103/jmp.jmp_11_26
UR  - https://doi.org/10.4103/jmp.jmp_11_26
AB  - Background: CyberKnife® stereotactic radiosurgery enables frameless, image-guided treatment of multiple brain metastases. Collimator type (Fixed vs. Iris) and planning strategy (Simultaneous vs. Separate) may influence low-dose normal brain exposure, plan quality, and treatment delivery efficiency. Objectives: The objective of the study was to compare the dosimetric performance of different collimator types and planning strategies in patients with three or four brain metastases under standardized planning conditions. Materials and Methods: Twenty patients were retrospectively replanned using four treatment configurations: Fixed Separate, Fixed Simultaneous, Iris Separate, and Iris Simultaneous. All plans were generated using identical prescription doses and planning objectives. Dosimetric evaluation included normal brain V8, V10, V12 (volumes receiving ≥8 Gy, ≥10 Gy, and ≥12 Gy), mean brain dose (Vmean), Paddick conformity index (PCI), and gradient index (GI). Comparisons were performed using Friedman and Wilcoxon signed-rank tests. Estimated treatment time was recorded for all plans. Results: Significant differences were observed for V8 (P = 0.039), Vmean (P = 0.019), and PCI (P < 0.001), whereas V10 (P = 0.180), V12 (P = 0.103), and GI (P = 0.420) showed no significant differences among the planning approaches. Median dosimetric values tended to favor Iris Simultaneous planning for reducing low-dose normal brain exposure. The significant PCI difference was primarily attributable to lower conformity in the Iris Separate plans. Total planning target volume demonstrated a near-significant positive association with V12 (P = 0.057). Iris-based plans were associated with shorter estimated treatment times. Conclusion: Under standardized planning conditions, Iris Simultaneous planning demonstrated favorable trends in reducing low-dose normal brain exposure while improving treatment delivery efficiency. Although conformity differed significantly among planning approaches, mainly because of lower PCI values in the Iris Separate plans, dose gradient characteristics remained comparable. These findings suggest that planning strategy may influence conformity more than dose fall-off in CyberKnife treatment of multiple brain metastases. Nevertheless, given the limited sample size, these results should be interpreted cautiously and validated in larger prospective studies.
SN  - 0971-6203
SN  - 1998-3913
ER  -