On the Limits of Efficiency in AI-Based Air Quality Monitoring for Health Risk Assessment.
- 1The Artificial Intelligence Research Center, Novosibirsk State University, 630090 Novosibirsk, Russia.
- 2Brain Science Institute, Russian Center of Neurology and Neuroscience, 105064 Moscow, Russia.
Abstract
Air pollution remains a leading global health risk, with chronic low-level toxicity documented below current regulatory limits. This has prompted calls to tighten air quality standards, yet the monitoring systems underlying risk assessment were not designed to operate at such low concentrations. Drawing on epidemiological evidence from the ELAPSE project on long-term exposure to major air pollutants, we develop a quantitative model of how AI-based air quality monitoring (AQM) quality affects the hazard ratio from Cox proportional hazards models. We show that AQM error systematically attenuates the estimated hazard ratio toward the null, and that this attenuation intensifies as concentrations decline. The reliability of the risk estimate is bounded above by the validation accuracy of the AI exposure model. Because the deep learning component of AQM error has an irreducible floor, increasing model complexity cannot eliminate the attenuation. We derive a quantitative sufficiency criterion that identifies the AQM accuracy beyond which further improvement yields no toxicologically meaningful gain and accumulates technical debt. The analysis identifies the epidemiological design, not the monitoring system, as the binding constraint on the accuracy of toxicity assessment at low concentrations, and provides a quantitative basis for deciding whether further investment in AQM is justified.
Related
- Assessment of routine facility-based monitoring of quality of reproductive, maternal, newborn, child, adolescent, elderly health and nutrition services in Cross River and Rivers States, Nigeria: cross-sectional study.
- Maternal Health Trends and Disparities in Hawaiʻi: Visualizing Pregnancy Risk Assessment Monitoring System Data Through an Interactive Shiny Web Application
- Relation between Promotive Health Behaviors, Self-Efficiency, and Quality of Life of the Elderly
- Monitoring Advanced Hydration Station (AHS) Water Quality in Flint, MI, School Buildings: Field Grab Sampling and Filter-Based Lead Assessment
- Perceived Electronic Health Record System Success and Its Associations With Healthcare Quality, Patient Safety, and Operational Efficiency in a Saudi Tertiary Hospital: A Cross-Sectional Survey Study
BibTeX
@article{shakhov2026limits,
title = {{On the Limits of Efficiency in AI-Based Air Quality Monitoring for Health Risk Assessment.}},
author = {Vladimir Shakhov and Irina Shakhova and Olga Sokolova},
journal = {Toxics},
year = {2026},
month = nov,
doi = {10.3390/toxics14111023},
url = {https://europepmc.org/article/MED/43083633},
note = {CC BY},
}
RIS
TY - JOUR
TI - On the Limits of Efficiency in AI-Based Air Quality Monitoring for Health Risk Assessment.
AU - Vladimir Shakhov
AU - Irina Shakhova
AU - Olga Sokolova
PY - 2026
DA - 2026/11/19
JO - Toxics
DO - 10.3390/toxics14111023
UR - https://europepmc.org/article/MED/43083633
AB - Air pollution remains a leading global health risk, with chronic low-level toxicity documented below current regulatory limits. This has prompted calls to tighten air quality standards, yet the monitoring systems underlying risk assessment were not designed to operate at such low concentrations. Drawing on epidemiological evidence from the ELAPSE project on long-term exposure to major air pollutants, we develop a quantitative model of how AI-based air quality monitoring (AQM) quality affects the hazard ratio from Cox proportional hazards models. We show that AQM error systematically attenuates the estimated hazard ratio toward the null, and that this attenuation intensifies as concentrations decline. The reliability of the risk estimate is bounded above by the validation accuracy of the AI exposure model. Because the deep learning component of AQM error has an irreducible floor, increasing model complexity cannot eliminate the attenuation. We derive a quantitative sufficiency criterion that identifies the AQM accuracy beyond which further improvement yields no toxicologically meaningful gain and accumulates technical debt. The analysis identifies the epidemiological design, not the monitoring system, as the binding constraint on the accuracy of toxicity assessment at low concentrations, and provides a quantitative basis for deciding whether further investment in AQM is justified.
SN - 2305-6304
ER -