Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 49 min ago
Peer-reviewedCC BYInternational wound journal

Textile-Integrated Electrochemical Sensing Approaches for Monitoring Wound-Relevant Biochemical Markers.

  1. 1Institute of Textile Machinery and High Performance Material Technology, Technische Universität Dresden, Dresden, Germany.
  2. 2Institut für Fördertechnik und Kunststoffe, Technische Universität Chemnitz, Chemnitz, Germany.
  3. 3Textilforschungsinstitut Thueringen-Vogtland e.V.-TITV Greiz, Yvonne Zimmermann, Greiz, Germany.

Abstract

Wearable electrochemical sensors offer promising opportunities for wound-related biochemical assessment by enabling the detection of wound-relevant biomarkers directly at the skin-wound interface. In this study, we present a textile-integrated sensor platform for dual-analyte response of hydrogen peroxide (H₂O₂) and enzymatically quantified lactate, which are key indicators of oxidative stress and metabolic activity, respectively. The redox sensor was fabricated using platinum-coated Shieldex working electrodes and Ag/AgCl reference electrodes, arranged in a coaxial winding yarn. Besides having the same type of reference electrode in the setup, the lactate sensor employed a gold-based working electrode functionalized with a chitosan-PPD-lactate oxidase (LOx) multilayer along with a platinum-based counter electrode. Electrochemical characterisation showed that the redox sensor exhibited consistent current-time response behaviour, approaching a quasi-stabilised response level within approximately 180 s, and demonstrating a measurable response trend across a broad experimentally explored H₂O₂ concentration range (from the micromolar to high millimolar range). The lactate sensor produced repeatable qualitative current increases of approximately 25% and 50% at 2 mM and 4 mM lactate, respectively, with response magnitude affected by pH and temperature. Biocompatibility testing confirmed no cytotoxic effects for gold- and platinum-based electrodes, and only moderate effects for Ag/AgCl under prolonged incubation, supporting the suitability of the primary sensing elements for wound-contact applications. Taken together, the results demonstrate proof-of-concept functionality under controlled laboratory conditions, while comprehensive analytical validation remains the subject of future work, which supports the potential of textile-based electrochemical sensors for integration into next-generation smart wound dressings. Future research will also focus on environmental compensation, enzyme stabilisation and further system optimisation for wound-relevant operation.

Related

  1. Integrated phenotypic, biochemical and SSR-based characterization of nutraceutical diversity in guava germplasm
    Maneesh Kumar, Rajesh Kumar, Daya Shankar Mishra +8
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPharmacology & toxicologyCrossref
  2. Evaluation of the gastroprotective mechanisms of the ethanol leaves extract of Jatropha multifida in ethanol-induced gastric ulceration in Wistar rats: Integrated in Vivo, biochemical, and in silico study
    Tochukwu R. Eze, Innocent O. Orhonigbe, Isioma C. Okonta +8
    Metabolism openPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Integrated counter current separation and omics approaches for discovery of bioactive compounds from medicinal plants
    Ananda Kumar Chettupalli, Priyanshu Pathak, Priya Sharma +2
    Frontiers in pharmacologyPeer-reviewedCC BYFull textPharmacology & toxicologyEurope PMC
  4. Outcomes of Comprehensive Multiple Sclerosis Care: A Pilot Comparison of Intensive, Integrated, and Usual Care Approaches
    Deborah Backus, W. Mark Sweatman, Tracy Walker +4
    International Journal of MS CarePeer-reviewedLicence not statedFull textGeneral medicinePMC
  5. A comparison of 68Ga-PSMA PET/MR, 18F-FDG PET/CT and biochemical monitoring in neuroendocrine prostate cancer: a case report
    Yuqi Deng, Xin Li, Jie Hu +2
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textOncologyCrossrefDOAJ
BibTeX
@article{khan2026textileintegrated,
  title = {{Textile-Integrated Electrochemical Sensing Approaches for Monitoring Wound-Relevant Biochemical Markers.}},
  author = {Adnan Maroof Khan and Johannes Wendler and Yvonne Zimmermann and Dilbar Aibibu and Michael Wöltje and Chokri Cherif},
  journal = {International wound journal},
  year = {2026},
  month = oct,
  doi = {10.1111/iwj.71083},
  url = {https://europepmc.org/article/MED/42958837},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Textile-Integrated Electrochemical Sensing Approaches for Monitoring Wound-Relevant Biochemical Markers.
AU  - Adnan Maroof Khan
AU  - Johannes Wendler
AU  - Yvonne Zimmermann
AU  - Dilbar Aibibu
AU  - Michael Wöltje
AU  - Chokri Cherif
PY  - 2026
DA  - 2026/10/29
JO  - International wound journal
DO  - 10.1111/iwj.71083
UR  - https://europepmc.org/article/MED/42958837
AB  - Wearable electrochemical sensors offer promising opportunities for wound-related biochemical assessment by enabling the detection of wound-relevant biomarkers directly at the skin-wound interface. In this study, we present a textile-integrated sensor platform for dual-analyte response of hydrogen peroxide (H₂O₂) and enzymatically quantified lactate, which are key indicators of oxidative stress and metabolic activity, respectively. The redox sensor was fabricated using platinum-coated Shieldex working electrodes and Ag/AgCl reference electrodes, arranged in a coaxial winding yarn. Besides having the same type of reference electrode in the setup, the lactate sensor employed a gold-based working electrode functionalized with a chitosan-PPD-lactate oxidase (LOx) multilayer along with a platinum-based counter electrode. Electrochemical characterisation showed that the redox sensor exhibited consistent current-time response behaviour, approaching a quasi-stabilised response level within approximately 180 s, and demonstrating a measurable response trend across a broad experimentally explored H₂O₂ concentration range (from the micromolar to high millimolar range). The lactate sensor produced repeatable qualitative current increases of approximately 25% and 50% at 2 mM and 4 mM lactate, respectively, with response magnitude affected by pH and temperature. Biocompatibility testing confirmed no cytotoxic effects for gold- and platinum-based electrodes, and only moderate effects for Ag/AgCl under prolonged incubation, supporting the suitability of the primary sensing elements for wound-contact applications. Taken together, the results demonstrate proof-of-concept functionality under controlled laboratory conditions, while comprehensive analytical validation remains the subject of future work, which supports the potential of textile-based electrochemical sensors for integration into next-generation smart wound dressings. Future research will also focus on environmental compensation, enzyme stabilisation and further system optimisation for wound-relevant operation.
SN  - 1742-4801
SN  - 1742-481X
ER  -