Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 3 min ago
Peer-reviewedCC BYCritical care (London, England)

Predictive performance of bedside physiological parameters for the failure of prophylactic non-invasive ventilation after extubation.

9 affiliations
  1. 1Department of Precision-Regenerative Medicine and Jonic Area (DiMepre-J), Section of Anesthesiology and Intensive Care Medicine, University of Bari "Aldo Moro", Bari, Italy. [email protected].
  2. 2Interdepartmental Division of Critical Care Medicine, Department of Medicine, University Health Network, Toronto General Hospital, Toronto, ON, Canada. [email protected].
  3. 3Interdepartmental Division of Critical Care Medicine, Medical and Surgical Intensive Care Unit, Toronto General Research Institute, University Health Network, Toronto, ON, Canada. [email protected].
  4. 4Department of Anesthesia, Intensive Care and Emergency. Fondazione Policlinico A. Gemelli IRCCS, Rome, Italy.
  5. 5Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Rome, Italy.
  6. 6Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Universitá di Brescia, Brescia, Italy.
  7. 7Department of Medicine, University of Padua, Padua, Italy.
  8. 8Department of Anesthesiology and Intensive Care Medicine, Ecclesiastical Entity - Regional General Hospital "F. Miulli", Acquaviva Delle Fonti, Bari, Italy AND University Department of Medicine & Surgery, Libera Università Mediterranea (LUM), Casamassima, Bari, Italy.
  9. 9Department of Precision-Regenerative Medicine and Jonic Area (DiMepre-J), Section of Anesthesiology and Intensive Care Medicine, University of Bari "Aldo Moro", Bari, Italy.

Abstract

Extubation failure is associated with increased mortality. Whether bedside physiological variables can identify patients at risk of reintubation during prophylactic NIV after extubation is unknown. In this post hoc analysis of a multicenter physiological study, 60 hypoxemic adults at high risk of extubation failure underwent two 1-hour NIV sessions after planned extubation, with oronasal and full-face masks in randomized crossover order. We assessed the magnitude of airway occlusion pressure (Pocc), the esophageal pressure swing (ΔPes), SpO₂/FiO₂, respiratory rate, tidal volume, dynamic lung elastance (EL,dyn), ROX index [(SpO₂/FiO₂)/respiratory rate] and the pressure-oxygenation index (POX, SpO₂/FiO₂ divided by Pocc). Prophylactic NIV failure was reintubation for respiratory failure within 7 days. Discrimination was assessed by ROC analysis. Fourteen patients (23%) experienced NIV failure. Pocc yielded areas under the curve (AUCs) of 0.83 (95% CI, 0.71-0.95) with the oronasal mask and 0.83 (95% CI, 0.72-0.95) with the full-face mask, showing greater discriminative performance than tidal volume (AUCs, 0.55 and 0.53), respiratory rate (0.54 and 0.38), SpO₂/FiO₂ (0.51 and 0.50), and the ROX index (0.54 and 0.38; all p < 0.05). By contrast, the discriminative performance of Pocc did not differ from that of EL,dyn (AUCs, 0.72 and 0.73; p = 0.08 and 0.11), POX (AUCs, 0.82 and 0.81; p = 0.68 and 0.29), or |ΔPes| (AUCs, 0.83 and 0.82; p = 1.00 and 0.64). During prophylactic NIV, Pocc discriminated NIV failure better than conventional bedside variables, with no detectable difference from directly measured inspiratory effort. External validation is required.

Related

  1. Sampling matters: the interplay of physiological parameters and performance over 1, 2 and 3 km in well-trained male endurance runners and sprinters
    Yannick M. Sondermann, Oliver J. Quittmann, Simon Nolte +4
    Frontiers in PhysiologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. Factors associated with non-adherence of secondary prophylactic drugs in ischemic stroke subjects and its correlation with chronic cognitive and motor performance
    Juan Yang, Hong Ma, Run Li +1
    American Journal of Translational ResearchPeer-reviewedLicence not statedFull textGeneral medicinePMC
  3. Association Between One-Lung Ventilation Parameters and Postoperative Pulmonary Infection After Radical Lung Cancer Surgery: A Retrospective Cohort Study
    Qianming Chen, Zhuangwen Hu, Yu Sheng +1
    Interdisciplinary Cardiovascular and Thoracic SurgeryPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  4. Predictive value of Lung Ultrasound Score for CPAP failure and mechanical ventilation among preterm neonates: a retrospective single-centre cohort study in Jordan
    Abedulrhman Abdelfattah, Ahmad Al-Azzam, Yihea Mohammad Al-Mashaqbeh +5
    BMJ Paediatrics OpenPeer-reviewedCC BY-NC 4.0Full textObstetrics, gynaecology & paediatricsDOAJPMC
  5. The MIME framework for non-invasive longitudinal assessment of inspiratory effort during pressure support ventilation: a physiological validation study.
    K Lindup, S Giovanazzi, S Renzetti +14
    Critical care (London, England)Peer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{murgolo2026predictive,
  title = {{Predictive performance of bedside physiological parameters for the failure of prophylactic non-invasive ventilation after extubation.}},
  author = {Francesco Murgolo and Domenico Luca Grieco and Michele Bertoni and Alessandro Cardu and Tommaso Pettenuzzo and Salvatore M Maggiore and Massimo Antonelli and Salvatore Grasso and INSPIRE study group},
  journal = {Critical care (London, England)},
  year = {2026},
  month = nov,
  doi = {10.1186/s13054-026-06453-4},
  url = {https://europepmc.org/article/MED/43065113},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Predictive performance of bedside physiological parameters for the failure of prophylactic non-invasive ventilation after extubation.
AU  - Francesco Murgolo
AU  - Domenico Luca Grieco
AU  - Michele Bertoni
AU  - Alessandro Cardu
AU  - Tommaso Pettenuzzo
AU  - Salvatore M Maggiore
AU  - Massimo Antonelli
AU  - Salvatore Grasso
AU  - INSPIRE study group
PY  - 2026
DA  - 2026/11/11
JO  - Critical care (London, England)
DO  - 10.1186/s13054-026-06453-4
UR  - https://europepmc.org/article/MED/43065113
AB  - Extubation failure is associated with increased mortality. Whether bedside physiological variables can identify patients at risk of reintubation during prophylactic NIV after extubation is unknown. In this post hoc analysis of a multicenter physiological study, 60 hypoxemic adults at high risk of extubation failure underwent two 1-hour NIV sessions after planned extubation, with oronasal and full-face masks in randomized crossover order. We assessed the magnitude of airway occlusion pressure (Pocc), the esophageal pressure swing (ΔPes), SpO₂/FiO₂, respiratory rate, tidal volume, dynamic lung elastance (EL,dyn), ROX index [(SpO₂/FiO₂)/respiratory rate] and the pressure-oxygenation index (POX, SpO₂/FiO₂ divided by Pocc). Prophylactic NIV failure was reintubation for respiratory failure within 7 days. Discrimination was assessed by ROC analysis. Fourteen patients (23%) experienced NIV failure. Pocc yielded areas under the curve (AUCs) of 0.83 (95% CI, 0.71-0.95) with the oronasal mask and 0.83 (95% CI, 0.72-0.95) with the full-face mask, showing greater discriminative performance than tidal volume (AUCs, 0.55 and 0.53), respiratory rate (0.54 and 0.38), SpO₂/FiO₂ (0.51 and 0.50), and the ROX index (0.54 and 0.38; all p < 0.05). By contrast, the discriminative performance of Pocc did not differ from that of EL,dyn (AUCs, 0.72 and 0.73; p = 0.08 and 0.11), POX (AUCs, 0.82 and 0.81; p = 0.68 and 0.29), or |ΔPes| (AUCs, 0.83 and 0.82; p = 1.00 and 0.64). During prophylactic NIV, Pocc discriminated NIV failure better than conventional bedside variables, with no detectable difference from directly measured inspiratory effort. External validation is required.
SN  - 1364-8535
SN  - 1466-609X
ER  -