Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BY-NC-NDNpj imaging

Investigation of Propagation Properties of Airy-like Beams for Light-Sheet Fluorescence Microscopy.

2 more authors
5 affiliations
  1. 1Academy of Medical Engineering and Translational Medicine, Medical College, Tianjin University, Tianjin, 300072, China.
  2. 2Central Hospital, Tianjin University, Tianjin, 300072, China.
  3. 3Academy of Medical Engineering and Translational Medicine, Medical College, Tianjin University, Tianjin, 300072, China. [email protected].
  4. 4Department of Physics and Tianjin Key Laboratory of Low Dimensional Materials Physics and Preparing Technology, School of Sciences, Tianjin University, Tianjin, 300350, China. [email protected].
  5. 5Academy of Medical Engineering and Translational Medicine, Medical College, Tianjin University, Tianjin, 300072, China. [email protected].

Abstract

This study investigates the electric field distribution of an extended class of diffraction-free Airy beams, termed Airy-like beams, aiming to identify an optimal configuration that balances field of view (FOV) and axial resolution for light-sheet fluorescence microscopy (LSFM). Based on the Olver function framework, we derived an analytical expression of the electric field through phase term superposition and established a mapping relationship between the pupil function and electric field distribution. Numerical simulations and modulation transfer function (MTF) analysis revealed that the optimal Airy-like beam form (m = 0 + 1) provides a more balanced trade-off between axial resolution and field of view than conventional Airy beams. Fluorescent microsphere experiments further demonstrate an axial resolution improvement of approximately 17.3% compared with conventional Airy beams. Validation through light-sheet imaging simulations and fluorescent microsphere experiments confirmed its improved imaging performance, particularly in peripheral regions. We further applied the optimized Airy-like beam to visualize cerebral vasculature in large-scale brain tissues, demonstrating its capability to resolve sophisticated structures consistently across an extended FOV. This result could be a clue for Airy-like beam design in advancing LSFM.

Related

  1. MUFASA: a continuous-time stochastic framework for realistic fluorescence microscopy simulation
    Wessim Omezzine, Sébastien Schaub, Laure Blanc-Féraud +1
    Communications BiologyPeer-reviewedCC BY-NC-ND 4.0Full textBiophysicsCrossref
  2. Adaptive multiband Dark sectioning for robust background removal in fluorescence microscopy
    Aykanbaier Kadier, Xiangcong Xu, Hechong Zhang +5
    Biomedical optics expressPeer-reviewedLicence not statedFull textBiophysicsEurope PMCEurope PMC
  3. Correlation-resolved sum-frequency generation microscopy of biological tissue with bright twin beams
    T.-H. Chen, M. Adachi, Z. Hu +6
    bioRxivPreprintCC BY-NC-NDFull textBiophysicsbioRxiv
  4. Quantitative Colocalization Analysis in Fluorescence Microscopy
    Charles James Myers, Beiyan Nan
    Bio-protocolPeer-reviewedCC BY 4.0Full textBiophysicsPMC
  5. High-precision correlative fluorescence and electron cryo microscopy using two independent alignment markers
    Pascale Schellenberger, Rainer Kaufmann, C. Alistair Siebert +3
    UltramicroscopyPeer-reviewedCC BYFull text118 citedStructural biologyHAL
BibTeX
@article{wang2026investigation,
  title = {{Investigation of Propagation Properties of Airy-like Beams for Light-Sheet Fluorescence Microscopy.}},
  author = {Yanni Wang and Qizhong Wang and Jianmin Ding and Rong Zhao and Siyu Ao and Xin Xiong and Shibo Li and Di Ma and Huizhen Ma and Zifan Wang and Zixin Yang and Hao Wang and Xiao-Dong Zhang and Pengfei Liu},
  journal = {Npj imaging},
  year = {2026},
  month = jul,
  doi = {10.1038/s44303-026-00186-3},
  url = {https://europepmc.org/article/MED/43078890},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Investigation of Propagation Properties of Airy-like Beams for Light-Sheet Fluorescence Microscopy.
AU  - Yanni Wang
AU  - Qizhong Wang
AU  - Jianmin Ding
AU  - Rong Zhao
AU  - Siyu Ao
AU  - Xin Xiong
AU  - Shibo Li
AU  - Di Ma
AU  - Huizhen Ma
AU  - Zifan Wang
AU  - Zixin Yang
AU  - Hao Wang
AU  - Xiao-Dong Zhang
AU  - Pengfei Liu
PY  - 2026
DA  - 2026/07/29
JO  - Npj imaging
DO  - 10.1038/s44303-026-00186-3
UR  - https://europepmc.org/article/MED/43078890
AB  - This study investigates the electric field distribution of an extended class of diffraction-free Airy beams, termed Airy-like beams, aiming to identify an optimal configuration that balances field of view (FOV) and axial resolution for light-sheet fluorescence microscopy (LSFM). Based on the Olver function framework, we derived an analytical expression of the electric field through phase term superposition and established a mapping relationship between the pupil function and electric field distribution. Numerical simulations and modulation transfer function (MTF) analysis revealed that the optimal Airy-like beam form (m = 0 + 1) provides a more balanced trade-off between axial resolution and field of view than conventional Airy beams. Fluorescent microsphere experiments further demonstrate an axial resolution improvement of approximately 17.3% compared with conventional Airy beams. Validation through light-sheet imaging simulations and fluorescent microsphere experiments confirmed its improved imaging performance, particularly in peripheral regions. We further applied the optimized Airy-like beam to visualize cerebral vasculature in large-scale brain tissues, demonstrating its capability to resolve sophisticated structures consistently across an extended FOV. This result could be a clue for Airy-like beam design in advancing LSFM.
SN  - 2948-197X
ER  -