Updated dosimetric comparison of HDR interventional radiotherapy including ⁶⁰Co sources versus VMAT and electron beam therapy for NMSC.
6 affiliations
- 1Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan.
- 2Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, Pakistan.
- 3Fondazione Policlinico Universitario Agostino Gemelli, IRCCS, Rome, Italy. [email protected].
- 4Università Cattolica del Sacro Cuore, Rome, Italy. [email protected].
- 5Fondazione Policlinico Universitario Agostino Gemelli, IRCCS, Rome, Italy.
- 6Università Cattolica del Sacro Cuore, Rome, Italy.
Abstract
Non-melanoma skin cancers (NMSCs), primarily basal cell carcinoma and squamous cell carcinoma, are the most common malignancies worldwide and frequently arise on the scalp, where complex curvature and anatomical constraints make treatment planning challenging. While surgery remains the standard approach, radiotherapy, particularly high-dose-rate interventional radiotherapy (HDR-IRT, modern brachytherapy), has become an important alternative for patients who are not ideal surgical candidates. Previous dosimetric analyses have demonstrated that ¹⁹²I HDR-IRT provides superior target coverage and dose conformity compared with external beam techniques such as volumetric modulated arc therapy (VMAT) and electron beam therapy (EBT). However, the reproducibility of these findings across centres and radioactive sources, including ⁶⁰Co, has not been systematically validated. This study aimed to independently validate prior dosimetric results by independently replanning the same cohort of 25 patients with scalp NMSC using ⁶⁰Co HDR-IRT. The objective was to assess whether the dosimetric advantages of HDR-IRT remain consistent when different operators, institutions, and isotopes are employed, and to compare ⁶⁰Co HDR-IRT with VMAT and EBT under identical clinical conditions. A retrospective dosimetric comparison was conducted using the original CT datasets from 25 patients previously analyzed with ¹⁹²Ir HDR-IRT. At an independent institution, new plans were generated for ⁶⁰Co HDR-IRT, VMAT, and EBT using the same contours, applicator geometry, prescription doses, and V95% constraints. HDR-IRT plans were constructed in Oncentra Brachy v4.6 based on TG-43 formalism; VMAT and EBT plans were generated in Eclipse TPS v16.1 using 6 MV photons and 6 MeV electrons, respectively. Dosimetric parameters (V90%, V95%, V100%, D90%, Dmean, Dmax) and brain D2cc values were extracted from DVHs. Statistical comparisons were performed with the Mann-Whitney U test (p < 0.05). All techniques provided comparable V90% (> 99%) and V95% values, ensuring consistent baseline coverage. However, HDR-IRT using Co-60 demonstrated significantly higher V100%, D90%, and Dmean values than VMAT and EBT across all prescription groups (p < 0.05). This reflects the proximity of the source to the target and the steep dose gradient inherent to brachytherapy. VMAT produced the most homogeneous dose distributions but at the expense of slightly reduced high-dose coverage. EBT performed adequately for small, flat lesions but showed pronounced limitations in large or curved anatomies, with increased variability and occasional hotspots in the brain. Brain D2cc doses remained comparable across modalities (p > 0.05), confirming adequate protection of critical structures. This external validation confirms that HDR-IRT retains its dosimetric superiority over VMAT and EBT even when replanned by different operators, at a different institution, and using an alternative isotope (⁶⁰Co instead of ¹⁹²Ir). The findings demonstrate that HDR-IRT is a robust and reproduciblemodality for scalp NMSC, capable of achieving excellent target coverage and rapid dose fall-off without compromising organ-at-risk sparing. These results strengthen the evidence supporting HDR-IRT as a reliable option for treating superficial scalp cancers across diverse clinical settings.
Related
- Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
- Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy
- Dosimetric Comparison of Contemporary Stereotactic Radiotherapy Platforms for Brain Metastases: Towards Personalized Technology Selection
- Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial
- CBCT-Guided Online Adaptive Ultrahypofractionated Whole-Breast Radiotherapy for Early-Stage Breast Cancer: Dosimetric Outcomes and Acute Toxicity.
BibTeX
@article{sajjad2026updated,
title = {{Updated dosimetric comparison of HDR interventional radiotherapy including ⁶⁰Co sources versus VMAT and electron beam therapy for NMSC.}},
author = {Sidra Sajjad and Muhammad Shahban and Enrico Rosa and Bruno Fionda and Humera Mehmood and M Basim Kakakhel and Luca Tagliaferri and Marco De Spirito and Elisa Placidi},
journal = {Radiation and environmental biophysics},
year = {2026},
month = oct,
doi = {10.1007/s00411-026-01258-z},
url = {https://europepmc.org/article/MED/42853377},
note = {CC BY},
}
RIS
TY - JOUR
TI - Updated dosimetric comparison of HDR interventional radiotherapy including ⁶⁰Co sources versus VMAT and electron beam therapy for NMSC.
AU - Sidra Sajjad
AU - Muhammad Shahban
AU - Enrico Rosa
AU - Bruno Fionda
AU - Humera Mehmood
AU - M Basim Kakakhel
AU - Luca Tagliaferri
AU - Marco De Spirito
AU - Elisa Placidi
PY - 2026
DA - 2026/10/09
JO - Radiation and environmental biophysics
DO - 10.1007/s00411-026-01258-z
UR - https://europepmc.org/article/MED/42853377
AB - Non-melanoma skin cancers (NMSCs), primarily basal cell carcinoma and squamous cell carcinoma, are the most common malignancies worldwide and frequently arise on the scalp, where complex curvature and anatomical constraints make treatment planning challenging. While surgery remains the standard approach, radiotherapy, particularly high-dose-rate interventional radiotherapy (HDR-IRT, modern brachytherapy), has become an important alternative for patients who are not ideal surgical candidates. Previous dosimetric analyses have demonstrated that ¹⁹²I HDR-IRT provides superior target coverage and dose conformity compared with external beam techniques such as volumetric modulated arc therapy (VMAT) and electron beam therapy (EBT). However, the reproducibility of these findings across centres and radioactive sources, including ⁶⁰Co, has not been systematically validated. This study aimed to independently validate prior dosimetric results by independently replanning the same cohort of 25 patients with scalp NMSC using ⁶⁰Co HDR-IRT. The objective was to assess whether the dosimetric advantages of HDR-IRT remain consistent when different operators, institutions, and isotopes are employed, and to compare ⁶⁰Co HDR-IRT with VMAT and EBT under identical clinical conditions. A retrospective dosimetric comparison was conducted using the original CT datasets from 25 patients previously analyzed with ¹⁹²Ir HDR-IRT. At an independent institution, new plans were generated for ⁶⁰Co HDR-IRT, VMAT, and EBT using the same contours, applicator geometry, prescription doses, and V95% constraints. HDR-IRT plans were constructed in Oncentra Brachy v4.6 based on TG-43 formalism; VMAT and EBT plans were generated in Eclipse TPS v16.1 using 6 MV photons and 6 MeV electrons, respectively. Dosimetric parameters (V90%, V95%, V100%, D90%, Dmean, Dmax) and brain D2cc values were extracted from DVHs. Statistical comparisons were performed with the Mann-Whitney U test (p < 0.05). All techniques provided comparable V90% (> 99%) and V95% values, ensuring consistent baseline coverage. However, HDR-IRT using Co-60 demonstrated significantly higher V100%, D90%, and Dmean values than VMAT and EBT across all prescription groups (p < 0.05). This reflects the proximity of the source to the target and the steep dose gradient inherent to brachytherapy. VMAT produced the most homogeneous dose distributions but at the expense of slightly reduced high-dose coverage. EBT performed adequately for small, flat lesions but showed pronounced limitations in large or curved anatomies, with increased variability and occasional hotspots in the brain. Brain D2cc doses remained comparable across modalities (p > 0.05), confirming adequate protection of critical structures. This external validation confirms that HDR-IRT retains its dosimetric superiority over VMAT and EBT even when replanned by different operators, at a different institution, and using an alternative isotope (⁶⁰Co instead of ¹⁹²Ir). The findings demonstrate that HDR-IRT is a robust and reproduciblemodality for scalp NMSC, capable of achieving excellent target coverage and rapid dose fall-off without compromising organ-at-risk sparing. These results strengthen the evidence supporting HDR-IRT as a reliable option for treating superficial scalp cancers across diverse clinical settings.
SN - 0301-634X
SN - 1432-2099
ER -