Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY-NC 4.0Technology in Cancer Research & Treatment

Dosimetric Comparison of Contemporary Stereotactic Radiotherapy Platforms for Brain Metastases: Towards Personalized Technology Selection

  1. 1Department of Radiotherapy, Affiliated Zhongshan Hospital of Dalian University, Dalian, China

Abstract

Stereotactic radiosurgery and radiotherapy (SRS/SRT) for brain metastases is a rapidly evolving field, driven by continuous refinement of dosimetric strategies and technological advances in treatment platforms. This narrative review synthesizes current evidence on the dosimetric characteristics of major SRS/SRT platforms—Gamma Knife, CyberKnife, ZAP-X, linear accelerators, helical tomotherapy, and proton therapy—and evaluates their comparative strengths, limitations, and optimal clinical applications. We identify distinct dosimetric trade-offs among platforms with respect to dose conformity, gradient fall-off, normal tissue sparing, and treatment efficiency. Gamma Knife remains a dosimetric benchmark for dose gradient steepness, particularly for small targets (e.g., <1 cm in diameter). CyberKnife offers high conformity and may benefit lesions adjacent to critical organs, although treatment efficiency diminishes with increasing numbers of metastases. The novel, self-shielded ZAP-X system delivers a dose gradient comparable to that of Gamma Knife and achieves favorable sparing of normal brain tissue at intermediate-to-high dose levels. Linear accelerator-based techniques—especially single-isocenter non-coplanar volumetric modulated arc therapy and dynamic conformal arc therapy—are widely adopted for multiple brain metastases owing to their high delivery efficiency and continually improving plan quality. Helical tomotherapy provides reliable plan deliverability, whereas proton therapy offers a theoretical advantage in reducing low-dose exposure to the whole brain and sparing adjacent organs at risk, owing to the Bragg peak. The available evidence indicates that no single platform is universally optimal, and dosimetric differences should be interpreted with caution given the absence of prospective comparative clinical outcome data. Treatment platform selection should therefore be individualized, integrating disease characteristics (e.g., number, volume, location, and geometry of targets), institutional resources, and established clinical priorities. Future integration of advanced technologies—including FLASH radiotherapy and artificial intelligence—may further personalize the management of brain metastases.

Related

  1. Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy
    Srikanth Guduru, Rohith Singareddy, N. V. N. Madhusudhana Sresty +2
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  2. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  3. Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial
    Mottareale R, Serra M, Pezzulla D +18
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
  4. Updated dosimetric comparison of HDR interventional radiotherapy including ⁶⁰Co sources versus VMAT and electron beam therapy for NMSC.
    Sidra Sajjad, Muhammad Shahban, Enrico Rosa +6
    Radiation and environmental biophysicsPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  5. Preliminary Feasibility and Dosimetric Evaluation of Retroperitoneal Hydrogel Spacer Placement for Stereotactic Body Radiation Therapy: A Cadaveric Study
    Shin Tanabe, Kotaro Yoshio, Takaaki Komiyama +9
    Advances in Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
BibTeX
@article{duan2026dosimetric,
  title = {{Dosimetric Comparison of Contemporary Stereotactic Radiotherapy Platforms for Brain Metastases: Towards Personalized Technology Selection}},
  author = {Wenyue Duan and Zhe Wang and Ruoyu Wang},
  journal = {Technology in Cancer Research \& Treatment},
  year = {2026},
  month = oct,
  doi = {10.1177/15330338261493387},
  url = {https://doi.org/10.1177/15330338261493387},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Dosimetric Comparison of Contemporary Stereotactic Radiotherapy Platforms for Brain Metastases: Towards Personalized Technology Selection
AU  - Wenyue Duan
AU  - Zhe Wang
AU  - Ruoyu Wang
PY  - 2026
DA  - 2026/10/01
JO  - Technology in Cancer Research & Treatment
DO  - 10.1177/15330338261493387
UR  - https://doi.org/10.1177/15330338261493387
AB  - Stereotactic radiosurgery and radiotherapy (SRS/SRT) for brain metastases is a rapidly evolving field, driven by continuous refinement of dosimetric strategies and technological advances in treatment platforms. This narrative review synthesizes current evidence on the dosimetric characteristics of major SRS/SRT platforms—Gamma Knife, CyberKnife, ZAP-X, linear accelerators, helical tomotherapy, and proton therapy—and evaluates their comparative strengths, limitations, and optimal clinical applications. We identify distinct dosimetric trade-offs among platforms with respect to dose conformity, gradient fall-off, normal tissue sparing, and treatment efficiency. Gamma Knife remains a dosimetric benchmark for dose gradient steepness, particularly for small targets (e.g., <1 cm in diameter). CyberKnife offers high conformity and may benefit lesions adjacent to critical organs, although treatment efficiency diminishes with increasing numbers of metastases. The novel, self-shielded ZAP-X system delivers a dose gradient comparable to that of Gamma Knife and achieves favorable sparing of normal brain tissue at intermediate-to-high dose levels. Linear accelerator-based techniques—especially single-isocenter non-coplanar volumetric modulated arc therapy and dynamic conformal arc therapy—are widely adopted for multiple brain metastases owing to their high delivery efficiency and continually improving plan quality. Helical tomotherapy provides reliable plan deliverability, whereas proton therapy offers a theoretical advantage in reducing low-dose exposure to the whole brain and sparing adjacent organs at risk, owing to the Bragg peak. The available evidence indicates that no single platform is universally optimal, and dosimetric differences should be interpreted with caution given the absence of prospective comparative clinical outcome data. Treatment platform selection should therefore be individualized, integrating disease characteristics (e.g., number, volume, location, and geometry of targets), institutional resources, and established clinical priorities. Future integration of advanced technologies—including FLASH radiotherapy and artificial intelligence—may further personalize the management of brain metastases.
SN  - 1533-0346
SN  - 1533-0338
ER  -