Aberration correction in fetal ultrasound: Clinical evaluation on image quality improvement

5 affiliations
  1. 1Department of Electrical Engineering Eindhoven University of Technology Eindhoven the Netherlands
  2. 2Department of Obstetrics and Gynecology Maxima Medical Centre Veldhoven the Netherlands
  3. 3Philips Ultrasound Paris France
  4. 4Philips Ultrasound Cambridge USA
  5. 5Department of Research and Medical Innovation Maxima Medical Centre Veldhoven the Netherlands

Abstract

Objective: Obstetric ultrasound is key for assessing fetal growth and detecting anomalies, with image quality critical for diagnostic accuracy. Maternal body mass index (BMI) and other factors can impair quality. Aberration correction (AC) aims to reduce image quality degradation. This prospective observational study assessed the effect of AC on fetal ultrasound image quality and biometric measurements.

Methods: Routine ultrasound images of the fetal head, abdomen, and heart were analyzed. The image quality score (IQS) and biometric measurements, including the circumference of the head, abdomen, and heart, were compared before and after AC. Intraclass correlations (ICC) were used to describe intra‐ and inter‐observer agreement of measurements. Secondary objective evaluated IQS subcomponents and outcomes stratified by BMI.

Results: The study included 186 images from 62 patients. IQS were significantly higher in AC‐images (median 14) compared with no‐AC images (median 13.5), with significance observed across both BMI groups and a more pronounced effect in the normal BMI group. Intra‐ and inter‐observer agreement for cardiac circumference improved after AC (0.907 to 0.987 and 0.873 to 0.925). For other measurements, agreement was excellent (>0.9) regardless of AC or BMI.

Conclusion: Aberration correction improved obstetric ultrasound by enhancing image quality and increasing the reliability of biometric measurements, particularly of smaller fetal structures. The results highlight the clinical potential of AC and lay the foundation for future research to assess its role in clinical practice.

Related

  1. Clinical decision support tool evaluation: Correction of direct oral anticoagulant dosing errors by clinical pharmacists and physicians
    Anish Saraswat, Shawna N. Smith, Michael P. Dorsch +5
    Research and Practice in Thrombosis and HaemostasisPeer-reviewedCC BYFull textEndocrinology & metabolismDOAJ
  2. The value of ultrasound semi-quantitative scoring in the clinical evaluation of acute gouty arthritis with normal and elevated serum uric acid
    Lizi Zhang, Tiesheng Yang, Jia Ge
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Efficacy and Safety of a Single Session of Micro‐Focused Ultrasound for Mid‐To‐Lower Facial Rejuvenation: A Retrospective Multimodal Assessment Study Using Clinical Evaluation, High‐Frequency Ultrasound, and VISIA Skin Analysis
    Yuanyuan Qu, Fang Xiang, Jiawen Ma +3
    Journal of Cosmetic DermatologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  4. Sustaining High-Dose Hemodiafiltration in Routine Clinical Practice: A Retrospective Evaluation of a Quality Improvement Intervention
    Younes Bathish, Louisa Rostom, Elite Elkobi +1
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  5. Discrepancy Between Radiographic Correction and Cosmetic Improvement in Adolescent Idiopathic Scoliosis: The Role of Extremely Low BMI.
    Weihang Chu, Abdukahar Kiram, Jie Li +8
    Global spine journalPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{dassen2026aberration,
  title = {{Aberration correction in fetal ultrasound: Clinical evaluation on image quality improvement}},
  author = {Sophie Dassen and Xufei Chen and Cybele Ciofolo‐Veit and Laurence Rouet and Jean‐Luc Robert and Jeanne Dieleman and Ruud Van Sloun and Loes Monen and Judith Van Laar},
  journal = {International Journal of Gynaecology and Obstetrics},
  year = {2026},
  month = jun,
  doi = {10.1002/ijgo.71125},
  url = {https://doi.org/10.1002/ijgo.71125},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Aberration correction in fetal ultrasound: Clinical evaluation on image quality improvement
AU  - Sophie Dassen
AU  - Xufei Chen
AU  - Cybele Ciofolo‐Veit
AU  - Laurence Rouet
AU  - Jean‐Luc Robert
AU  - Jeanne Dieleman
AU  - Ruud Van Sloun
AU  - Loes Monen
AU  - Judith Van Laar
PY  - 2026
DA  - 2026/06/30
JO  - International Journal of Gynaecology and Obstetrics
DO  - 10.1002/ijgo.71125
UR  - https://doi.org/10.1002/ijgo.71125
AB  - Objective: Obstetric ultrasound is key for assessing fetal growth and detecting anomalies, with image quality critical for diagnostic accuracy. Maternal body mass index (BMI) and other factors can impair quality. Aberration correction (AC) aims to reduce image quality degradation. This prospective observational study assessed the effect of AC on fetal ultrasound image quality and biometric measurements.  Methods: Routine ultrasound images of the fetal head, abdomen, and heart were analyzed. The image quality score (IQS) and biometric measurements, including the circumference of the head, abdomen, and heart, were compared before and after AC. Intraclass correlations (ICC) were used to describe intra‐ and inter‐observer agreement of measurements. Secondary objective evaluated IQS subcomponents and outcomes stratified by BMI.  Results: The study included 186 images from 62 patients. IQS were significantly higher in AC‐images (median 14) compared with no‐AC images (median 13.5), with significance observed across both BMI groups and a more pronounced effect in the normal BMI group. Intra‐ and inter‐observer agreement for cardiac circumference improved after AC (0.907 to 0.987 and 0.873 to 0.925). For other measurements, agreement was excellent (>0.9) regardless of AC or BMI.  Conclusion: Aberration correction improved obstetric ultrasound by enhancing image quality and increasing the reliability of biometric measurements, particularly of smaller fetal structures. The results highlight the clinical potential of AC and lay the foundation for future research to assess its role in clinical practice.
SN  - 0020-7292
SN  - 1879-3479
ER  -