Signal-Generating Materials in Cross-Reactive Molecularly Imprinted Polymer Arrays for Multiplexed Sensing: From Materials Design to Computational Decoding.
- 1Department of Medical and Digital Engineering, College of Engineering, Hanyang University, Seoul 04736, Republic of Korea.
- 2Department of Biomedical Engineering, College of Engineering, Hanyang University, Seoul 04736, Republic of Korea.
- 3Department of Pharmacology, College of Medicine, Hanyang University, Seoul 04736, Republic of Korea.
Abstract
In biosensor design, molecularly imprinted polymers (MIPs) function as synthetic recognition matrices that create structurally selective binding sites through template-directed imprinting and can incorporate or interface with signal-generating units to convert binding events into measurable outputs. Although MIP-based sensors have traditionally focused on single-analyte detection, many applications in biomedical diagnostics, food safety, environmental monitoring, and point-of-care testing require simultaneous discrimination of multiple chemically related targets in complex samples. Conventional multiplexed MIP sensing relies primarily on spatially separated sensor elements or multi-template imprinting. Although these approaches have enabled substantial progress, they often require additional sensing compartments, electrodes, readout pathways, or spectrally resolved signals as the number of targets increases. Accordingly, a key challenge is to generate multiple analyte-dependent responses within a compact sensing format, such as a single well, sensing region, or integrated array, without expanding the number of physical channels. Cross-reactive MIP arrays offer a complementary strategy by employing partially selective receptors to generate multidimensional response patterns that can be computationally decoded. In this context, multiplexing capacity depends not only on imprinting chemistry but also on signal-generating materials that translate MIP-analyte interactions into measurable features. This review examines optical probes, electrochemical materials, plasmonic nanoparticles, porous frameworks, and two-dimensional materials as the candidate signal-generating components of cross-reactive MIP arrays. Such arrays have so far been directly demonstrated only with colorimetric, structural-color, and carbon-dot fluorescent readouts and with conducting-polymer electronic tongues, whereas the discussion of plasmonic, porous-framework, and two-dimensional materials rests on single-analyte demonstrations and is presented as a prospective design opportunity. It also discusses chemometric, machine learning, and artificial intelligence-based decoding strategies, which are increasingly important for extracting analyte-specific information from nonlinear, high-dimensional, and partially overlapping signals. Future advances will require the co-design of MIP receptors, signal-generating materials, compact array architectures, and drift-aware AI models for robust real-world multiplexed sensing.
Related
- Electropolymerized Molecularly Imprinted Polymers Supported on Carbon-Based Materials for (Bio)sensing: Direct and Indirect Detection Strategies
- Full-Factorial Formulation Screening and Model Protein Sensing with Electropolymerized Molecularly Imprinted Polymer-Modified Electrodes
- Development and Optimization of a Molecularly Imprinted Polymer for Electrochemical Detection of Escherichia coli
- Dual Molecularly Imprinted Mesoporous Organosilica Nanoprobes for AI-Assisted Glutathione Redox Ratio Sensing
- Stimulus-responsive molecularly imprinted polymers for bisphenol A and dibutyl phthalate: Analytical trends, challenges, and future perspectives
BibTeX
@article{lee2026signalgenerating,
title = {{Signal-Generating Materials in Cross-Reactive Molecularly Imprinted Polymer Arrays for Multiplexed Sensing: From Materials Design to Computational Decoding.}},
author = {Solpa Lee and Seoyeon Baek and Yongwoo Jang},
journal = {Biosensors},
year = {2026},
month = nov,
doi = {10.3390/bios16110638},
url = {https://europepmc.org/article/MED/43082533},
note = {CC BY},
}
RIS
TY - JOUR
TI - Signal-Generating Materials in Cross-Reactive Molecularly Imprinted Polymer Arrays for Multiplexed Sensing: From Materials Design to Computational Decoding.
AU - Solpa Lee
AU - Seoyeon Baek
AU - Yongwoo Jang
PY - 2026
DA - 2026/11/07
JO - Biosensors
DO - 10.3390/bios16110638
UR - https://europepmc.org/article/MED/43082533
AB - In biosensor design, molecularly imprinted polymers (MIPs) function as synthetic recognition matrices that create structurally selective binding sites through template-directed imprinting and can incorporate or interface with signal-generating units to convert binding events into measurable outputs. Although MIP-based sensors have traditionally focused on single-analyte detection, many applications in biomedical diagnostics, food safety, environmental monitoring, and point-of-care testing require simultaneous discrimination of multiple chemically related targets in complex samples. Conventional multiplexed MIP sensing relies primarily on spatially separated sensor elements or multi-template imprinting. Although these approaches have enabled substantial progress, they often require additional sensing compartments, electrodes, readout pathways, or spectrally resolved signals as the number of targets increases. Accordingly, a key challenge is to generate multiple analyte-dependent responses within a compact sensing format, such as a single well, sensing region, or integrated array, without expanding the number of physical channels. Cross-reactive MIP arrays offer a complementary strategy by employing partially selective receptors to generate multidimensional response patterns that can be computationally decoded. In this context, multiplexing capacity depends not only on imprinting chemistry but also on signal-generating materials that translate MIP-analyte interactions into measurable features. This review examines optical probes, electrochemical materials, plasmonic nanoparticles, porous frameworks, and two-dimensional materials as the candidate signal-generating components of cross-reactive MIP arrays. Such arrays have so far been directly demonstrated only with colorimetric, structural-color, and carbon-dot fluorescent readouts and with conducting-polymer electronic tongues, whereas the discussion of plasmonic, porous-framework, and two-dimensional materials rests on single-analyte demonstrations and is presented as a prospective design opportunity. It also discusses chemometric, machine learning, and artificial intelligence-based decoding strategies, which are increasingly important for extracting analyte-specific information from nonlinear, high-dimensional, and partially overlapping signals. Future advances will require the co-design of MIP receptors, signal-generating materials, compact array architectures, and drift-aware AI models for robust real-world multiplexed sensing.