Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 8 min ago
PreprintCC BY 4.0arXiv

Review of oxygen measurement and relevance to the mechanisms of FLASH radiotherapy

Abstract

FLASH radiotherapy (FLASH-RT) is the phenomenon of relative sparing of normal tissue when ultra-high dose rates (UHDR) are used compared with conventional dose rates (CDR) as clinically used. Despite extensive investigation, the underlying mechanisms remain unexplained. Among the proposed hypotheses, tissue oxygen has consistently been a central theme because oxygen is the most dominant factor known to modulate radiation-induced damage. The factors implicated in FLASH sparing include the baseline partial pressure of oxygen (pO2), transient radiolytic oxygen consumption (ROC), and oxygen-dependent changes in the chemistry of reactive oxygen species (ROS) that vary with dose rate. This review synthesizes current evidence on in vivo oxygen measurement techniques, highlighting their capabilities and limitations in capturing the spatial and temporal heterogeneity of tissue oxygenation. Key experimental studies in skin are summarized and interpreted by modulating oxygen levels via changes in inspired oxygen gas and vascular clamping interventions, demonstrating that the FLASH effect occurs only at intermediate baseline pO2 (normoxic or slightly hypoxic) values, but not at hypoxia or hyperoxia. Direct measurement of oxygen consumption during UHDR irradiation is possible, providing one of the first in situ measurements of radiation chemistry in patients. In parallel, recent advances in fast in vitro radiation chemistry assays indicate that UHDR irradiation alters radical yields, favoring increased production of solvated electrons and reduced hydroxyl radical mediated damage. Taken together, the available data suggest that the FLASH sparing effect arises from an interplay among the delivered dose and dose rate, local oxygen availability, and radiation chemistry, with tissue-specific variation in scavenging, leading to altered biological responses across the CDR-to-UHDR shift.

Versions

Related

  1. Relevance between patients' clinical factors and 4D-CT lung ventilation heterogeneity for evaluating the adoption of functional avoidance thoracic radiotherapy with a large patient database.
    Guozhong Deng, Yongquan Ying, Xiaomei Wang +5
    Frontiers in oncologyPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMCCrossref
  2. 3D analysis and evolution of prostate and tumor oxygenation using MRI-derived relative oxygen extraction fraction during MR-guided stereotactic body radiotherapy☆
    Thomas Berger, Ariane Lapierre, Perla Zidane +8
    Physics and imaging in radiation oncologyPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMCHAL
  3. First double-differential measurement of pionless charged-current muon neutrino interactions using kinematic imbalance observables on carbon and oxygen with the T2K experiment
    K. Abe, S. Abe, H. Adhikary +403
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  4. Efficacy and safety of single-fraction stereotactic body radiotherapy (SBRT) for the curative treatment of extracranial primary Tumors: A collaborative systematic review on behalf of the SBRT Focus Group of the European Society for Radiotherapy & Oncology (ESTRO).
    Francesco Cuccia, Ciro Franzese, Suraiya Dubash +9
    Clinical and translational radiation oncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
  5. Artificial intelligence in image-guided cervical interventional radiotherapy: a systematic review
    Valentina Lancellotta, Angeles Rovirosa, Maria Concetta La Milia +12
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossrefEurope PMCEurope PMCPMC
BibTeX
@misc{pogue2026review,
  title = {{Review of oxygen measurement and relevance to the mechanisms of FLASH radiotherapy}},
  author = {Brian W. Pogue and David I. Hunter and Corbin Narita and William S. Thomas and Xu Cao and Harold M. Swartz},
  howpublished = {arXiv},
  year = {2026},
  month = jul,
  doi = {10.48550/arxiv.2607.17974},
  eprint = {2607.17974},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2607.17974},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Review of oxygen measurement and relevance to the mechanisms of FLASH radiotherapy
AU  - Brian W. Pogue
AU  - David I. Hunter
AU  - Corbin Narita
AU  - William S. Thomas
AU  - Xu Cao
AU  - Harold M. Swartz
PY  - 2026
DA  - 2026/07/20
PB  - arXiv
DO  - 10.48550/arxiv.2607.17974
UR  - https://arxiv.org/abs/2607.17974
AB  - FLASH radiotherapy (FLASH-RT) is the phenomenon of relative sparing of normal tissue when ultra-high dose rates (UHDR) are used compared with conventional dose rates (CDR) as clinically used. Despite extensive investigation, the underlying mechanisms remain unexplained. Among the proposed hypotheses, tissue oxygen has consistently been a central theme because oxygen is the most dominant factor known to modulate radiation-induced damage. The factors implicated in FLASH sparing include the baseline partial pressure of oxygen (pO2), transient radiolytic oxygen consumption (ROC), and oxygen-dependent changes in the chemistry of reactive oxygen species (ROS) that vary with dose rate. This review synthesizes current evidence on in vivo oxygen measurement techniques, highlighting their capabilities and limitations in capturing the spatial and temporal heterogeneity of tissue oxygenation. Key experimental studies in skin are summarized and interpreted by modulating oxygen levels via changes in inspired oxygen gas and vascular clamping interventions, demonstrating that the FLASH effect occurs only at intermediate baseline pO2 (normoxic or slightly hypoxic) values, but not at hypoxia or hyperoxia. Direct measurement of oxygen consumption during UHDR irradiation is possible, providing one of the first in situ measurements of radiation chemistry in patients. In parallel, recent advances in fast in vitro radiation chemistry assays indicate that UHDR irradiation alters radical yields, favoring increased production of solvated electrons and reduced hydroxyl radical mediated damage. Taken together, the available data suggest that the FLASH sparing effect arises from an interplay among the delivered dose and dose rate, local oxygen availability, and radiation chemistry, with tissue-specific variation in scavenging, leading to altered biological responses across the CDR-to-UHDR shift.
ER  -