Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BY-NC-NDJournal of NeuroEngineering and Rehabilitation

Feasibility of the Meta Quest 3 for upper limb kinematic analysis: accuracy, consistency, agreement and reliability

4 affiliations
  1. 1Neurorehabilitation and Brain Research Group, Human-Centered Technology Research Institute, Universitat Politècnica de València, Valencia, Spain
  2. 2Faculty of Physical Activity and Sports Sciences, Universitat de València, Valencia, Spain
  3. 3Institute of Mechanical and Biomechanical Engineering, Universitat Politècnica de València, Valencia, Spain
  4. 4Neurorehabilitation and Brain Research Group, Human-Centered Technology Research Institute, Universitat Politècnica de València, Valencia, Spain. [email protected]

Abstract

BACKGROUND: Upper limb motor impairment is a frequent long-term consequence of a wide range of neurological and musculoskeletal conditions. Accurate assessment of motor function is essential to determine patient's condition and plan adequate interventions. While clinical scales are easy to administer and not time-consuming, they could have limited accuracy and be biased. Kinematic analysis can provide detailed, quantitative information but usually depends on expensive, complex, and non-portable systems. Recent virtual reality head-mounted displays, with integrated hand-tracking, offer a promising, low-cost, and portable alternative to conduct upper limb kinematic assessment. However, the accuracy, consistency, agreement and reliability of kinematic variables derived from the hand tracking feature of these devices, as well as the impact of signal preprocessing on feature extraction, remain largely unexplored. METHODS: Thirty-nine healthy subjects performed five upper-limb tasks including tracking, point-reaching, and reach-and-grasp, while their movements were simultaneously recorded using a laboratory-grade motion capture system and the Meta Quest 3 headset. Multiple kinematic variables were extracted from the hand trajectories of both systems and analysed to evaluate accuracy, consistency, agreement and reliability. Additionally, the impact of signal smoothing on the extracted kinematic values was examined. RESULTS: Minimal absolute and relative errors were estimated between systems, showing high concordance and consistency across most kinematic variables and tasks. Importantly, the differences observed remained below the minimal detectable change of the motion capture system. Test-retest reliability of kinematic measures estimated by the Meta Quest 3 was moderate to good for nearly all variables with the only exception of the number of movement units, which consistently showed poor reliability across all tasks, indicating limited robustness of this metric. The signal smoothing was found to influence the magnitude of the estimated errors, highlighting the importance of optimizing the preprocessing to maximize the accuracy of the Meta Quest 3. CONCLUSIONS: Our findings support the feasibility of using the Meta Quest 3 as a cost-effective and portable alternative to laboratory-grade motion capture systems for kinematic evaluation of upper-limb motor function. However, caution is warranted regarding the selection of variables and tasks, particularly for metrics with limited robustness.

Related

  1. Kinematic encoding of the speed-accuracy trade-off in approach/avoidance decisions when facing social threats
    Rocco Mennella, Julie Grezes, Matteo Sequestro +1
    PsyArXivPreprintCC BY 4.0Full textNeuroscienceOSF
  2. From pose estimation accuracy to motor biomarker reliability: a reliability-centred evaluation framework for markerless movement analysis
    Valentin Fernandez, Khabiba Abdiyeva, Sébastien Brot +3
    Frontiers in neuroinformaticsPeer-reviewedCC BYFull textNeuroscienceEurope PMC
  3. Vivaray Hb pro non-invasive hemoglobin device: A prospective diagnostic accuracy study measuring agreement with a calibrated blood cell counter
    Devesh Kumar, Sunita Kapoor, Ambanna Gowda +3
    PLOS OnePeer-reviewedCC BY 4.0Full textGeneral biochemistryCell biologyPLOSPMC
  4. Auditory Steady-State Responses in Adults Aged 88-95 Years Measured in a Home Setting: Feasibility and Agreement with Pure-Tone Audiometry.
    Åsa Winzell Juhlin, Andreas Björsne, Birgitta Wallström Berg +5
    Audiology researchPeer-reviewedCC BYFull textNeuroscienceEurope PMC
  5. AlphaFold 3 Prediction Accuracy and Reliability across RNA Structures and Protein-RNA Interfaces
    I. K. Tennie, M. Uhl, J. K. H. Franke +2
    bioRxivPreprintCC BYFull textBioinformatics & computational biologybioRxiv
BibTeX
@article{campos2026feasibility,
  title = {{Feasibility of the Meta Quest 3 for upper limb kinematic analysis: accuracy, consistency, agreement and reliability}},
  author = {Gloria Campos and Gabriela Calvo and Adrián Borrego and Luis Millán and Alvaro F. Page and Roberto Lloréns},
  journal = {Journal of NeuroEngineering and Rehabilitation},
  year = {2026},
  month = jun,
  doi = {10.1186/s12984-026-02038-y},
  url = {https://doi.org/10.1186/s12984-026-02038-y},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Feasibility of the Meta Quest 3 for upper limb kinematic analysis: accuracy, consistency, agreement and reliability
AU  - Gloria Campos
AU  - Gabriela Calvo
AU  - Adrián Borrego
AU  - Luis Millán
AU  - Alvaro F. Page
AU  - Roberto Lloréns
PY  - 2026
DA  - 2026/06/10
JO  - Journal of NeuroEngineering and Rehabilitation
DO  - 10.1186/s12984-026-02038-y
UR  - https://doi.org/10.1186/s12984-026-02038-y
AB  - BACKGROUND: Upper limb motor impairment is a frequent long-term consequence of a wide range of neurological and musculoskeletal conditions. Accurate assessment of motor function is essential to determine patient's condition and plan adequate interventions. While clinical scales are easy to administer and not time-consuming, they could have limited accuracy and be biased. Kinematic analysis can provide detailed, quantitative information but usually depends on expensive, complex, and non-portable systems. Recent virtual reality head-mounted displays, with integrated hand-tracking, offer a promising, low-cost, and portable alternative to conduct upper limb kinematic assessment. However, the accuracy, consistency, agreement and reliability of kinematic variables derived from the hand tracking feature of these devices, as well as the impact of signal preprocessing on feature extraction, remain largely unexplored. METHODS: Thirty-nine healthy subjects performed five upper-limb tasks including tracking, point-reaching, and reach-and-grasp, while their movements were simultaneously recorded using a laboratory-grade motion capture system and the Meta Quest 3 headset. Multiple kinematic variables were extracted from the hand trajectories of both systems and analysed to evaluate accuracy, consistency, agreement and reliability. Additionally, the impact of signal smoothing on the extracted kinematic values was examined. RESULTS: Minimal absolute and relative errors were estimated between systems, showing high concordance and consistency across most kinematic variables and tasks. Importantly, the differences observed remained below the minimal detectable change of the motion capture system. Test-retest reliability of kinematic measures estimated by the Meta Quest 3 was moderate to good for nearly all variables with the only exception of the number of movement units, which consistently showed poor reliability across all tasks, indicating limited robustness of this metric. The signal smoothing was found to influence the magnitude of the estimated errors, highlighting the importance of optimizing the preprocessing to maximize the accuracy of the Meta Quest 3. CONCLUSIONS: Our findings support the feasibility of using the Meta Quest 3 as a cost-effective and portable alternative to laboratory-grade motion capture systems for kinematic evaluation of upper-limb motor function. However, caution is warranted regarding the selection of variables and tasks, particularly for metrics with limited robustness.
SN  - 1743-0003
ER  -