Fluorescent Sensing of Ferric Ions in Water Using Hydrothermally Derived Cu-Doped Dual-Emissive Carbon Dots.
- 1Department of Health Inspection and Quarantine, School of Public Health, Fujian Medical University, Fuzhou 350122, China.
- 2School of Materials and Chemistry Engineering, Minjiang University, Fuzhou 350108, China.
- 3College of Food Engineering, Zhangzhou Institute of Technology, Zhangzhou 363000, China.
Abstract
Iron is an important parameter in environmental water analysis, where its concentration strongly influences water quality and environmental behavior, thus necessitating its detection in aqueous samples. Herein, we report a simple, label-free fluorescent sensing platform based on copper-doped dual-emission carbon dots (CuCDs) for the rapid and quantitative detection of Fe³⁺ in aqueous media. CuCDs were synthesized via a one-step hydrothermal method using Cu (NO₃)₂·3H₂O and tryptamine (C₁₀H₁₂N₂) as precursors at 180 °C for 6 h. The resulting CuCDs exhibited two characteristic emission peaks at 336 nm and 395 nm under 290 nm excitation, and their fluorescence was selectively quenched by Fe³⁺. Under optimized conditions (MES buffer, pH 5, 60 °C, 10 min reaction time), the fluorescence intensity ratio (F₀/F) showed a linear correlation with Fe³⁺ concentration in the range of 20-700 μM at both emission wavelengths, yielding limits of detection of 11.68 μM (336 nm) and 10.07 μM (395 nm). The sensor demonstrated good selectivity against eleven common coexisting metal ions at 100-fold concentrations. Practical applicability was validated through spiked recovery assays in Min River water samples, achieving recoveries of 84.4-119.5% with results consistent with those obtained via standard atomic absorption spectrometry. The method offers low cost, a 10 min response time, and operational simplicity, providing a proof-of-concept basis for environmental water screening and future portable implementation.
Related
- Rhodamine-derived ratiometric fluorescent molecular rotor for mitochondrial viscosity sensing
- Red emissive carbon dots derived from raspberry leaves for enhanced photosynthesis in pea (Pisum sativum L.) seedlings
- Fluorescent Metal–Organic Frameworks for Chemical Sensing: Design Strategies, Mechanisms, and Analytical Applications
- Synthesis and crystal structure of a one-dimensional Hg(II) coordination polymer with two distinct metal centers and its selective fluorescent sensing of Ni²⁺
- Multimodal Fluorescent MOF@BODIPY Platform: Bridging Sensing and Mechanistic Insight
BibTeX
@article{you2026fluorescent,
title = {{Fluorescent Sensing of Ferric Ions in Water Using Hydrothermally Derived Cu-Doped Dual-Emissive Carbon Dots.}},
author = {Jinchao You and Zhiqiang Chen and Xiaohao Gan and Tian Shen and Lina Zheng and Chen Zhang and Ye He},
journal = {Biosensors},
year = {2026},
month = nov,
doi = {10.3390/bios16110635},
url = {https://europepmc.org/article/MED/43082530},
note = {CC BY},
}
RIS
TY - JOUR
TI - Fluorescent Sensing of Ferric Ions in Water Using Hydrothermally Derived Cu-Doped Dual-Emissive Carbon Dots.
AU - Jinchao You
AU - Zhiqiang Chen
AU - Xiaohao Gan
AU - Tian Shen
AU - Lina Zheng
AU - Chen Zhang
AU - Ye He
PY - 2026
DA - 2026/11/05
JO - Biosensors
DO - 10.3390/bios16110635
UR - https://europepmc.org/article/MED/43082530
AB - Iron is an important parameter in environmental water analysis, where its concentration strongly influences water quality and environmental behavior, thus necessitating its detection in aqueous samples. Herein, we report a simple, label-free fluorescent sensing platform based on copper-doped dual-emission carbon dots (CuCDs) for the rapid and quantitative detection of Fe³⁺ in aqueous media. CuCDs were synthesized via a one-step hydrothermal method using Cu (NO₃)₂·3H₂O and tryptamine (C₁₀H₁₂N₂) as precursors at 180 °C for 6 h. The resulting CuCDs exhibited two characteristic emission peaks at 336 nm and 395 nm under 290 nm excitation, and their fluorescence was selectively quenched by Fe³⁺. Under optimized conditions (MES buffer, pH 5, 60 °C, 10 min reaction time), the fluorescence intensity ratio (F₀/F) showed a linear correlation with Fe³⁺ concentration in the range of 20-700 μM at both emission wavelengths, yielding limits of detection of 11.68 μM (336 nm) and 10.07 μM (395 nm). The sensor demonstrated good selectivity against eleven common coexisting metal ions at 100-fold concentrations. Practical applicability was validated through spiked recovery assays in Min River water samples, achieving recoveries of 84.4-119.5% with results consistent with those obtained via standard atomic absorption spectrometry. The method offers low cost, a 10 min response time, and operational simplicity, providing a proof-of-concept basis for environmental water screening and future portable implementation.
SN - 2079-6374