Development of a Portable Multi-Detector for Indoor Air Quality Monitoring in Schools: Preliminary Results About Formaldehyde Measurements

Abstract

Indoor air quality (IAQ) in schools is a major public-health concern, as pupils and staff spend extended periods in classrooms where air renewal, occupancy, and material emissions interact. A portable multi-detector was developed to monitor key indoor pollutants, namely carbon dioxide, particulate matter, total volatile organic compounds, and formaldehyde, using compact low-cost sensors integrated into an embedded acquisition system. The paper focuses on the description of the multi-detector and presents measurements obtained during a six-week campaign conducted in fourteen classrooms across five elementary schools under real operating conditions, with particular attention to formaldehyde data. Results show significant spatial and temporal variability of formaldehyde concentrations between classrooms, with median values ranging from 2 to 28 ppb. All measured concentrations remain below the WHO and ANSES short-term guideline (80 ppb), while only five classrooms exhibit median values below the French long-term guideline of 8 ppb. These findings highlight the relevance of multi-parameter monitoring for assessing exposure to indoor pollutants in school environments.

Related

  1. Development of hybrid amine-functionalized diatom-based materials for efficient formaldehyde adsorption under dry and humid conditions
    Zakia Souissen, Anaïs Becker, Fabrice Vigneron +5
    Chemical Engineering Journal AdvancesPeer-reviewedCC BY 4.0Full textMaterials & polymersTheoretical & computational chemistryHAL
  2. Monitoring Short-Term Moisture Progression in Superabsorbent Polymer-Modified Mortar Using Hygro-Electrical Measurements
    Borhan Uddin Rabbani, Jung Heum Yeon
    PolymersPeer-reviewedCC BY 4.0Environmental science & pollutionCrossref
  3. Global monitoring of methane point sources using deep learning on hyperspectral radiance measurements from EMIT
    Vishal Batchu, Michelangelo Conserva, Alex Wilson +5
    Proceedings of the National Academy of SciencesPeer-reviewedCC BY5 citedClimate scienceOpenAlex
  4. Environmental sustainability in sports clubs: development and preliminary validation of the GreenTennis-SUSCLUB questionnaire
    Juan Alfonso García-Roca, María José Maciá-Andreu, María T. Morales-Belando +4
    Frontiers in sports and active livingPeer-reviewedCC BYFull textEnvironmental science & pollutionEurope PMCPMCEurope PMC
  5. Development of a lightweight broadband cavity-enhanced spectrometer system for simultaneous monitoring of HONO and NO2
    Yilan Li, Caroline C. Womack, Nell B. Schafer +1
    EGUspherePreprintCC BY 4.0General earth scienceEGUsphere
BibTeX
@article{jebeniani2026development,
  title = {{Development of a Portable Multi-Detector for Indoor Air Quality Monitoring in Schools: Preliminary Results About Formaldehyde Measurements}},
  author = {Hamza Jebeniani and André Canosa and Amina Meslem and Gisèle El Dib},
  journal = {Chemical Engineering Transactions},
  year = {2026},
  month = oct,
  doi = {10.3303/cet26127011},
  url = {https://hal.science/hal-05794364v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Development of a Portable Multi-Detector for Indoor Air Quality Monitoring in Schools: Preliminary Results About Formaldehyde Measurements
AU  - Hamza Jebeniani
AU  - André Canosa
AU  - Amina Meslem
AU  - Gisèle El Dib
PY  - 2026
DA  - 2026/10/12
JO  - Chemical Engineering Transactions
DO  - 10.3303/cet26127011
UR  - https://hal.science/hal-05794364v1
AB  - Indoor air quality (IAQ) in schools is a major public-health concern, as pupils and staff spend extended periods in classrooms where air renewal, occupancy, and material emissions interact. A portable multi-detector was developed to monitor key indoor pollutants, namely carbon dioxide, particulate matter, total volatile organic compounds, and formaldehyde, using compact low-cost sensors integrated into an embedded acquisition system. The paper focuses on the description of the multi-detector and presents measurements obtained during a six-week campaign conducted in fourteen classrooms across five elementary schools under real operating conditions, with particular attention to formaldehyde data. Results show significant spatial and temporal variability of formaldehyde concentrations between classrooms, with median values ranging from 2 to 28 ppb. All measured concentrations remain below the WHO and ANSES short-term guideline (80 ppb), while only five classrooms exhibit median values below the French long-term guideline of 8 ppb. These findings highlight the relevance of multi-parameter monitoring for assessing exposure to indoor pollutants in school environments.
SN  - 1974-9791
SN  - 2283-9216
ER  -