Competence in the use of a semi-automated external defibrillator among undergraduate dental students: evaluation and proposal for improvement

  1. 1Research Group in Medical-Surgical Dentistry, Health Research Institute of Santiago de Compostela, Faculty of Medicine and Dentistry, University of Santiago de Compostela

Abstract

Background The dental clinical setting is inherently stressful and may precipitate medical emergencies, including life-threatening cardiovascular events. Dentists carry both an ethical and legal responsibility to promptly recognize and effectively manage such situations. This responsibility demands not only training in cardiopulmonary resuscitation but also proficiency in the correct use of a semi-automatic external defibrillator. The present study aims to evaluate the competence of final-year dental students in operating a semi-automatic external defibrillator within a simulated scenario, to identify critical deficiencies in performance, and to determine the impact of providing clearer and more precise verbal instructions. Methods A group of final-year dental students from the University of Santiago de Compostela, Spain, participated in a simulation-based assessment using a simulation manikin involving a confirmed cardiorespiratory arrest scenario. In the first phase, students followed the conventional instructions provided by the semi-automatic external defibrillator. Based on the errors detected, a modified set of instructions was developed and applied in the second phase. Ten items, grouped into 3 categories—preparation, electrode placement and shock delivery, and post-shock actions—were evaluated. Results Of a total of 87 eligible students, 81 (93.1%) participated in the study. In the first phase, 42 students followed the conventional semi-automated external defibrillator instructions, whereas 39 students participated in the second phase using the modified instructions. Performance during the first phase was suboptimal: in 8 out of 10 assessed items, fewer than 10% (range 0-9.5%) of learners correctly completed the required actions. The median time to shock delivery was 143 s (95% CI 129–156 s). In the second phase, significant improvements were observed compared to the first phase in the following items: device activation (p < 0.001), adherence to instructions (p < 0.001), electrode connection (p = 0.006), and safety check prior to shock delivery (p < 0.001). The median time to shock delivery decreased to 116 s (95% CI 107–124 s) (p < 0.001). Conclusions Dental students demonstrate insufficient preparedness for the use of a semi-automatic external defibrillator. However, the provision of clearer verbal instructions markedly improves performance. These findings support the integration of specific training on the use of the semi-automatic external defibrillator into the dental curriculum.

Related

  1. Ability of clinical assessment methods to differentiate levels of competence in undergraduate nursing education: a scoping review protocol.
    Mohamad AlMekkawi, Mohammed Al Maqbali, Reem Al Sheryani +1
    BMJ openPeer-reviewedCC BY-NCFull textEpidemiology & public healthEurope PMCCrossref
  2. Effectiveness and retention of learning the use of an automated external defibrillator in adolescents: a comparative analysis of three teaching methods.
    Marcos Mecías-Calvo, Rubén Navarro-Patón
    Health education researchPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. Clinical Officers' Competence in Case Management: An Outcome Evaluation of the Competence‐Based Curriculum in Tanzanian Primary Health Facilities
    Ahmed Isare, Henry Mollel, Lawrencia Mushi
    Health science reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Peer Evaluation Rating Behavior in Differentiating Student Performance in Undergraduate Medical Education: An Observational Study
    Megan Woolford, Yuan Zhao, Hallie Evans +2
    Medical Science EducatorPeer-reviewedLicence not statedFull textEpidemiology & public healthPMC
  5. Early Exposure to Neonatal Neurology and Cranial Ultrasound: A Pilot Evaluation of an Undergraduate Course
    Andrea Calandrino, Samuele Caruggi, Mariya Malova +7
    Pediatric reportsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{tayebihillali2026competence,
  title = {{Competence in the use of a semi-automated external defibrillator among undergraduate dental students: evaluation and proposal for improvement}},
  author = {Hoda Tayebi-Hillali and Marta Aballe and Denisse Santana and Iván Varela-Aneiros and Márcio Diniz-Freitas and Pedro Diz-Dios},
  journal = {BMC Medical Education},
  year = {2026},
  month = jul,
  doi = {10.1186/s12909-026-10025-z},
  url = {https://doi.org/10.1186/s12909-026-10025-z},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Competence in the use of a semi-automated external defibrillator among undergraduate dental students: evaluation and proposal for improvement
AU  - Hoda Tayebi-Hillali
AU  - Marta Aballe
AU  - Denisse Santana
AU  - Iván Varela-Aneiros
AU  - Márcio Diniz-Freitas
AU  - Pedro Diz-Dios
PY  - 2026
DA  - 2026/07/01
JO  - BMC Medical Education
DO  - 10.1186/s12909-026-10025-z
UR  - https://doi.org/10.1186/s12909-026-10025-z
AB  - Background The dental clinical setting is inherently stressful and may precipitate medical emergencies, including life-threatening cardiovascular events. Dentists carry both an ethical and legal responsibility to promptly recognize and effectively manage such situations. This responsibility demands not only training in cardiopulmonary resuscitation but also proficiency in the correct use of a semi-automatic external defibrillator. The present study aims to evaluate the competence of final-year dental students in operating a semi-automatic external defibrillator within a simulated scenario, to identify critical deficiencies in performance, and to determine the impact of providing clearer and more precise verbal instructions. Methods A group of final-year dental students from the University of Santiago de Compostela, Spain, participated in a simulation-based assessment using a simulation manikin involving a confirmed cardiorespiratory arrest scenario. In the first phase, students followed the conventional instructions provided by the semi-automatic external defibrillator. Based on the errors detected, a modified set of instructions was developed and applied in the second phase. Ten items, grouped into 3 categories—preparation, electrode placement and shock delivery, and post-shock actions—were evaluated. Results Of a total of 87 eligible students, 81 (93.1%) participated in the study. In the first phase, 42 students followed the conventional semi-automated external defibrillator instructions, whereas 39 students participated in the second phase using the modified instructions. Performance during the first phase was suboptimal: in 8 out of 10 assessed items, fewer than 10% (range 0-9.5%) of learners correctly completed the required actions. The median time to shock delivery was 143 s (95% CI 129–156 s). In the second phase, significant improvements were observed compared to the first phase in the following items: device activation (p < 0.001), adherence to instructions (p < 0.001), electrode connection (p = 0.006), and safety check prior to shock delivery (p < 0.001). The median time to shock delivery decreased to 116 s (95% CI 107–124 s) (p < 0.001). Conclusions Dental students demonstrate insufficient preparedness for the use of a semi-automatic external defibrillator. However, the provision of clearer verbal instructions markedly improves performance. These findings support the integration of specific training on the use of the semi-automatic external defibrillator into the dental curriculum.
SN  - 1472-6920
ER  -