Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BYFrontiers in bioengineering and biotechnology

UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings.

  1. 1Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.

Abstract

Virus-like particles (VLPs), including those derived from adeno-associated virus (AAV), are increasingly investigated for vaccination, capsid engineering, and gene-delivery applications. Although precipitation and aqueous two-phase separation (ATPS) represent promising alternatives to adsorption-based capture, their optimization is limited by the lack of rapid analytical methods suitable for complex process samples. Here, VP3-only AAV5 VLPs produced in Escherichia coli were used as a model system to evaluate UV-derived light scattering as a high-throughput separation readout. Blank-corrected absorbance at 320 nm was used as a relative descriptor of particulate-associated scattering, while scattering-corrected absorbance at 280 nm monitored the soluble biomolecular fraction. During PEG precipitation, A320 showed condition-dependent agreement with anti-AAV5 ELISA, with the closest correspondence for PEG4000 and increasing divergence at lower PEG molecular weights. Capsid-spiking experiments further showed that dispersed intact capsids alone contributed only marginally to A320, indicating that the signal primarily reflects larger scattering-active structures accompanying capsid depletion. The workflow enabled screening and analysis of 170 precipitation and PEG/phosphate ATPS conditions in biological duplicate within 3 days. Low-molecular-weight PEG systems provided stronger separation between soluble biomolecular material and particulate-associated scattering. In PEG400 ATPS, pH altered the distribution of scattering-active material and capsids between the liquid phases and interphase, whereas selected precipitation conditions showed higher recovery of assembled capsids after resolubilization than ATPS, at the expense of lower impurity removal. Overall, UV-derived scattering provides a rapid, scalable first-line readout for comparing separation conditions and reducing the number of samples requiring capsid-specific and structural characterization.

Related

  1. High-Throughput Plasma Proteomic Profiling Identifies Novel Biomarker Candidates in Parkinson’s Disease with Cognitive Decline
    Shervin Khosousi, Latha Velayudhan, Xiaoping Yang +4
    Molecular & Cellular ProteomicsPeer-reviewedLicence not statedProteomics & metabolomicsCrossref
  2. High-throughput screen identifies a potent MCU activator boosting cardiac contractile bioenergetics
    E. CALDERO-ESCUDERO, M. Federico, A. Sanchez-Gonzalez +17
    bioRxivPreprintAll rights reservedFull textMolecular biology & gene regulationbioRxiv
  3. Protocol for high-throughput identification of genes involved in pyroptotic cell death by live microscopy.
    Aleksandra Bajger, Lukasz S Borowski, Roman J Szczesny +1
    STAR protocolsPeer-reviewedCC BY-NC-NDFull textMolecular biology & gene regulationEurope PMC
  4. A high-throughput 96-well plate method to measure human uterine contractility
    Emilie Huon, Justine Rayssac, Marie-Charlotte Lamau +6
    Frontiers in PharmacologyPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationPMCCrossrefEurope PMC
  5. High-throughput affinity profiling of antibodies against soluble and native membrane targets by digital flow cytometry
    Y. Cheng, S. Barcy, B. Fujimoto +3
    bioRxivPreprintCC BY-NC-NDFull textBiophysicsbioRxivPMC
BibTeX
@article{polazzo2026uvderived,
  title = {{UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings.}},
  author = {Giulia Polazzo and Malte Schwarzer and Jürgen Hubbuch},
  journal = {Frontiers in bioengineering and biotechnology},
  year = {2026},
  month = oct,
  doi = {10.3389/fbioe.2026.1913731},
  url = {https://europepmc.org/article/MED/42948107},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings.
AU  - Giulia Polazzo
AU  - Malte Schwarzer
AU  - Jürgen Hubbuch
PY  - 2026
DA  - 2026/10/13
JO  - Frontiers in bioengineering and biotechnology
DO  - 10.3389/fbioe.2026.1913731
UR  - https://europepmc.org/article/MED/42948107
AB  - Virus-like particles (VLPs), including those derived from adeno-associated virus (AAV), are increasingly investigated for vaccination, capsid engineering, and gene-delivery applications. Although precipitation and aqueous two-phase separation (ATPS) represent promising alternatives to adsorption-based capture, their optimization is limited by the lack of rapid analytical methods suitable for complex process samples. Here, VP3-only AAV5 VLPs produced in Escherichia coli were used as a model system to evaluate UV-derived light scattering as a high-throughput separation readout. Blank-corrected absorbance at 320 nm was used as a relative descriptor of particulate-associated scattering, while scattering-corrected absorbance at 280 nm monitored the soluble biomolecular fraction. During PEG precipitation, A320 showed condition-dependent agreement with anti-AAV5 ELISA, with the closest correspondence for PEG4000 and increasing divergence at lower PEG molecular weights. Capsid-spiking experiments further showed that dispersed intact capsids alone contributed only marginally to A320, indicating that the signal primarily reflects larger scattering-active structures accompanying capsid depletion. The workflow enabled screening and analysis of 170 precipitation and PEG/phosphate ATPS conditions in biological duplicate within 3 days. Low-molecular-weight PEG systems provided stronger separation between soluble biomolecular material and particulate-associated scattering. In PEG400 ATPS, pH altered the distribution of scattering-active material and capsids between the liquid phases and interphase, whereas selected precipitation conditions showed higher recovery of assembled capsids after resolubilization than ATPS, at the expense of lower impurity removal. Overall, UV-derived scattering provides a rapid, scalable first-line readout for comparing separation conditions and reducing the number of samples requiring capsid-specific and structural characterization.
SN  - 2296-4185
ER  -