Validation of a FLASH-ready 25 MeV proton beamline for preclinical radiobiology experiments
Abstract
Objective. Ultra-high dose rate irradiation (FLASH) is a promising way to reduce the adverse effects of radiotherapy treatment. However, the impact of dosimetric parameters on the FLASH effect is still not well understood and few devices can deliver irradiation in FLASH conditions. The aim of this study is to demonstrate the capability of a 25 MeV proton beamline to deliver the prescribed dose to a biological sample in conventional and FLASH conditions. Approach. We characterized the different parameters influencing dose delivery (beam energy, irradiation time, beam intensity) to confirm the accuracy of our irradiation protocol. In parallel, we developed a Monte-Carlo simulation of the beamline for irradiation planning. Then dose uniformity and reproducibility with respect to dose rate were then evaluated using radiochromic films. Main results. The uncertainty on dose delivery is around 1% for both conventional and FLASH dose rates. Dose monitoring shows that the prescribed dose is delivered within a margin of 3%, with a uniformity better than 5% for a dose rate up to 150 Gy s−1. The results of the Monte-Carlo simulation of the beamline are in strong agreement with our experimental measurements, thus validating the model. Significance. This work demonstrates the validation of a passive irradiation beamline delivering uniform irradiation with dose rates up to 150 Gy s−1 for centimetric irradiation fields. By characterizing beam parameters independently, we propose a dose validation method for beam energies where standard dose-calibrated detectors cannot be used.
Related
- Relative and absolute dosimetric commissioning of the ELIMAIA--ELIMED laser-driven proton beamline at 23.4 MeV
- 3-D Kinetics Experiments With Negative Reactivity Insertions in CROCUS for the Validation of TRIPOLI-4
- Cardio-respiratory-gated proton pencil beam scanning for cardiac ablation: workflow and end-to-end validation
- On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron
- Automated end-station at the soft X-ray beamline featuring robotic air-to-ultrahigh-vacuum sample transfer, scanning probe spectroscopy, and machine learning analysis
BibTeX
@article{simonin2026validation,
title = {{Validation of a FLASH-ready 25 MeV proton beamline for preclinical radiobiology experiments}},
author = {G Simonin and R Jbara and M Pellicioli and J Schuler and D Brasse and M Rousseau},
journal = {Phys.Med.Biol.},
year = {2026},
month = sep,
doi = {10.1088/1361-6560/ae2aa2},
url = {https://hal.science/hal-05502043v1},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Validation of a FLASH-ready 25 MeV proton beamline for preclinical radiobiology experiments
AU - G Simonin
AU - R Jbara
AU - M Pellicioli
AU - J Schuler
AU - D Brasse
AU - M Rousseau
PY - 2026
DA - 2026/09/30
JO - Phys.Med.Biol.
DO - 10.1088/1361-6560/ae2aa2
UR - https://hal.science/hal-05502043v1
AB - Objective. Ultra-high dose rate irradiation (FLASH) is a promising way to reduce the adverse effects of radiotherapy treatment. However, the impact of dosimetric parameters on the FLASH effect is still not well understood and few devices can deliver irradiation in FLASH conditions. The aim of this study is to demonstrate the capability of a 25 MeV proton beamline to deliver the prescribed dose to a biological sample in conventional and FLASH conditions. Approach. We characterized the different parameters influencing dose delivery (beam energy, irradiation time, beam intensity) to confirm the accuracy of our irradiation protocol. In parallel, we developed a Monte-Carlo simulation of the beamline for irradiation planning. Then dose uniformity and reproducibility with respect to dose rate were then evaluated using radiochromic films. Main results. The uncertainty on dose delivery is around 1% for both conventional and FLASH dose rates. Dose monitoring shows that the prescribed dose is delivered within a margin of 3%, with a uniformity better than 5% for a dose rate up to 150 Gy s^−1. The results of the Monte-Carlo simulation of the beamline are in strong agreement with our experimental measurements, thus validating the model. Significance. This work demonstrates the validation of a passive irradiation beamline delivering uniform irradiation with dose rates up to 150 Gy s^−1 for centimetric irradiation fields. By characterizing beam parameters independently, we propose a dose validation method for beam energies where standard dose-calibrated detectors cannot be used.
ER -