Skip to content
DraconiticResearch
Search Sources API
186,123 studies31 sourcesUpdated 45 min ago
Peer-reviewedCC BY-NC-ND 4.0Scientific Reports

Reliability and validity of the one-minute sit-to-stand test in Parkinson’s disease

Abstract

To investigate the validity and test–retest reliability of the One-Minute Sit-to-Stand Test (1STS) in individuals with Parkinson’s disease (PD). Twenty-eight individuals with PD performed the 1STS twice with a 7-day interval. Concurrent validity was examined using correlations with the 2-Minute Walk Test (2MWT) and the Hoehn and Yahr (H&Y) stage. Test–retest reliability was assessed using the intraclass correlation coefficient (ICC). The 1STS showed a strong positive correlation with the 2MWT (r = 0.69, p < 0.01) and a moderate negative correlation with the H&Y stage (r = − 0.58, p < 0.01). Test–retest reliability was excellent (ICC = 0.94, 95% CI: 0.86–0.97). The 1STS is a reliable and potentially valid measure of functional performance in individuals with PD. It may be considered a practical option in clinical settings; however, further research is needed to confirm these findings.

Versions

Related

  1. Validity Gates Expose Limits of Longitudinal Multimodal Parkinson Disease Prediction
    H. Tirhekar, P. Yadav, C. L. bajaj
    medRxivPreprintCC BY-NC-NDFull textEpidemiology & public healthmedRxiv
  2. The reliability and validity study of the Turkish version of the Uncertainty about Disease and Treatment Scale in hemodialysis patients.
    Reva Gündoğan, Onur Çetinkaya, Mümin Savaş
    BMC nephrologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCDOAJ
  3. Reliability of Myotonometric Measurements and Their Associations with Motor Performance in Parkinson's Disease.
    Lucía Latorre-Tomillo, Eduardo Villamil-Cabello, Noa Fogelson +1
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textNeurologyEurope PMC
  4. Intra-Rater Test-Retest Reliability of Static Dual-Task Balance Measures in Untrained People with Parkinson's Disease.
    Sara Monleón Guinot, Constanza San Martín Valenzuela, Vivina Aranda Asensi +1
    Neurology internationalPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. The Reliability and Validity of a Novel Isometric Trunk Rotation Strength Test
    International journal of sports physical therapyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{ceylan2026reliability,
  title = {{Reliability and validity of the one-minute sit-to-stand test in Parkinson’s disease}},
  author = {İsmail Ceylan and Muhammed Samed Dalakçı and Mehmet Canlı and Büşra Kürtüncüoğlu and Meltem Yücel Ilgar and Büşra Aydın and Halil Alkan and İrem Canlı},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-76425-9},
  url = {https://www.nature.com/articles/s41598-026-76425-9},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Reliability and validity of the one-minute sit-to-stand test in Parkinson’s disease
AU  - İsmail Ceylan
AU  - Muhammed Samed Dalakçı
AU  - Mehmet Canlı
AU  - Büşra Kürtüncüoğlu
AU  - Meltem Yücel Ilgar
AU  - Büşra Aydın
AU  - Halil Alkan
AU  - İrem Canlı
PY  - 2026
DA  - 2026/10/16
JO  - Scientific Reports
DO  - 10.1038/s41598-026-76425-9
UR  - https://www.nature.com/articles/s41598-026-76425-9
AB  - To investigate the validity and test–retest reliability of the One-Minute Sit-to-Stand Test (1STS) in individuals with Parkinson’s disease (PD). Twenty-eight individuals with PD performed the 1STS twice with a 7-day interval. Concurrent validity was examined using correlations with the 2-Minute Walk Test (2MWT) and the Hoehn and Yahr (H&Y) stage. Test–retest reliability was assessed using the intraclass correlation coefficient (ICC). The 1STS showed a strong positive correlation with the 2MWT (r = 0.69, p < 0.01) and a moderate negative correlation with the H&Y stage (r = − 0.58, p < 0.01). Test–retest reliability was excellent (ICC = 0.94, 95% CI: 0.86–0.97). The 1STS is a reliable and potentially valid measure of functional performance in individuals with PD. It may be considered a practical option in clinical settings; however, further research is needed to confirm these findings.
SN  - 2045-2322
ER  -