Skip to content
DraconiticResearch
Search Sources API
197,693 studies31 sourcesUpdated 40 min ago
PreprintCC BY-NC-NDmedRxiv

PROSPECTIVE COMPARISON OF OPTIMIZED COMPRESSED SENSING AND GRAPPA-ACCELERATED 3D-TOF-MRA FOR EVALUATION OF UNTREATED INTRACRANIAL ANEURYSMS AT 1.5 T: A NON-INFERIORITY STUDY

  1. 1Institute of Radiology and Neuroradiology, Evangelisches Krankenhaus Oldenburg, Steinweg 13-17, 26122 Oldenburg, Niedersachsen, Germany

Abstract

RATIONALE AND OBJECTIVES 3D-TOF-MRA is a standard non-invasive method for detecting and monitoring intracranial aneurysms, but long scan times remain a limitation. Compressed sensing (CS) acceleration for intracranial aneurysm evaluation has mainly been studied at 3T. This prospective single-center non-inferiority study compared CS-accelerated 3D-TOF at 1.5T with GRAPPA-accelerated 3D-TOF-MRA for evaluating untreated intracranial aneurysms. MATERIALS AND METHODS Sample size was determined via a preliminary retrospective study. 25 patients with 32 untreated aneurysms underwent both CS- (factor 7, 3:04 min) and GRAPPA-accelerated (factor 2, 5:00 min) 3D-TOF, yielding a 38.7% scan-time reduction. Two blinded neuroradiologists assessed overall image quality (primary endpoint) and artifacts, subjective CNR, aneurysm delineation and diameters (secondary endpoints). Non-inferiority was tested via one-sided t-test (prespecified 10% margin); interrater agreement used ICC. RESULTS CS demonstrated non-inferiority to GRAPPA for overall image quality in both readers (p <= .023), though interrater agreement was low (ICC 0.241-0.262), reflecting subjective variability. Secondary exploratory analyses showed heterogeneous preferences. ROI-based CNR was lower for CS (median 169.6; IQR, 91.0-226. vs. 278.2; 181.0-366.2). Aneurysm diameter measurements showed excellent interrater agreement for both techniques (CS ICC, 0.899-0.980; GRAPPA ICC, 0.877-0.973; all p < .001). CONCLUSION CS-accelerated 3D-TOF at 1.5T met non-inferiority criteria vs. GRAPPA-TOF for overall image quality, reducing scan time by 38.7% while preserving aneurysm measurement reliability. However, reduced CNR and reader-preference variability important trade-offs.

Related

  1. AI-accelerated compressed sensing and deep learning reconstruction for colon MRI: prospective validation of image quality and preliminary assessment of staging accuracy versus contrast-enhanced CT
    Zhen Guan, Nan Sun, Tian-Jing Chang +7
    Insights into ImagingPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyCrossrefPMC
  2. ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 T
    C. G. Iacoban, C. Klüner, H. Bösenberg +5
    medRxivPreprintCC BY-NC-NDFull textMedical imaging & radiologymedRxiv
  3. Performance of compressed-sensing cardiac accelerated cine MR in evaluating left ventricular function: a systematic review and meta-analysis
    Zhaozhao Wang, Huihui Kong, Zekun Zhou +5
    BMC Medical ImagingPeer-reviewedCC BYFull textMedical imaging & radiologyDOAJ
  4. A Prospective, Randomized, Non-inferiority Clinical Protocol Comparing the Efficacy and Safety of Single-port versus Multiport Extraperitoneal Robotic Radical Prostatectomy Using the KangDuo Robotic System
    T. Gu
    medRxivPreprintCC BYFull textSurgery & anaesthesiamedRxiv
  5. Efficacy and safety of pancrelipase delayed-release capsules (CREON®) from new manufacturing sites: a prospective, multicenter, randomized, double-blind, active-controlled, two-part, two-period, two-sequence, crossover, non-inferiority study
    Richard Ahrens, Daniel Layish, Lino Rodrigues +6
    TrialsPeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
BibTeX
@misc{iacoban2026prospective,
  title = {{PROSPECTIVE COMPARISON OF OPTIMIZED COMPRESSED SENSING AND GRAPPA-ACCELERATED 3D-TOF-MRA FOR EVALUATION OF UNTREATED INTRACRANIAL ANEURYSMS AT 1.5 T: A NON-INFERIORITY STUDY}},
  author = {C. G. Iacoban and H. Bösenberg and C. Klüner and O. Alykova and M. Gerdes and F. Meinert and B. Sundermann and C. Mathys},
  howpublished = {medRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.02.26367077},
  url = {https://www.medrxiv.org/content/10.64898/2026.11.02.26367077v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - PROSPECTIVE COMPARISON OF OPTIMIZED COMPRESSED SENSING AND GRAPPA-ACCELERATED 3D-TOF-MRA FOR EVALUATION OF UNTREATED INTRACRANIAL ANEURYSMS AT 1.5 T: A NON-INFERIORITY STUDY
AU  - C. G. Iacoban
AU  - H. Bösenberg
AU  - C. Klüner
AU  - O. Alykova
AU  - M. Gerdes
AU  - F. Meinert
AU  - B. Sundermann
AU  - C. Mathys
PY  - 2026
DA  - 2026/11/02
PB  - medRxiv
DO  - 10.64898/2026.11.02.26367077
UR  - https://www.medrxiv.org/content/10.64898/2026.11.02.26367077v1
AB  - RATIONALE AND OBJECTIVES 3D-TOF-MRA is a standard non-invasive method for detecting and monitoring intracranial aneurysms, but long scan times remain a limitation. Compressed sensing (CS) acceleration for intracranial aneurysm evaluation has mainly been studied at 3T. This prospective single-center non-inferiority study compared CS-accelerated 3D-TOF at 1.5T with GRAPPA-accelerated 3D-TOF-MRA for evaluating untreated intracranial aneurysms. MATERIALS AND METHODS Sample size was determined via a preliminary retrospective study. 25 patients with 32 untreated aneurysms underwent both CS- (factor 7, 3:04 min) and GRAPPA-accelerated (factor 2, 5:00 min) 3D-TOF, yielding a 38.7% scan-time reduction. Two blinded neuroradiologists assessed overall image quality (primary endpoint) and artifacts, subjective CNR, aneurysm delineation and diameters (secondary endpoints). Non-inferiority was tested via one-sided t-test (prespecified 10% margin); interrater agreement used ICC. RESULTS CS demonstrated non-inferiority to GRAPPA for overall image quality in both readers (p <= .023), though interrater agreement was low (ICC 0.241-0.262), reflecting subjective variability. Secondary exploratory analyses showed heterogeneous preferences. ROI-based CNR was lower for CS (median 169.6; IQR, 91.0-226. vs. 278.2; 181.0-366.2). Aneurysm diameter measurements showed excellent interrater agreement for both techniques (CS ICC, 0.899-0.980; GRAPPA ICC, 0.877-0.973; all p < .001). CONCLUSION CS-accelerated 3D-TOF at 1.5T met non-inferiority criteria vs. GRAPPA-TOF for overall image quality, reducing scan time by 38.7% while preserving aneurysm measurement reliability. However, reduced CNR and reader-preference variability important trade-offs.
ER  -