Standard-length compactors facilitate anatomic implantation of short humeral stems: a comparative radiographic study
- 1Centre Orthopédique Santy, FIFA Medical Center of Excellence, Groupe Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, Lyon, France
- 2Hand and Upper Extremity Surgical Institute, Clinique du Medipole, Villeurbanne, France
Abstract
Background
To investigate in shoulder arthroplasty whether standard-length compactors can be used to insert short and standard-length stems along the anatomic axis of the humerus without excessive filling ratios and to compare short stems implanted with standard-length vs. short compactors.Methods
A retrospective radiographic study was performed on patients who underwent shoulder arthroplasty with a short-stem ARAMIS prosthesis between December 2020 and December 2021 or with a standard-length ARAMIS prosthesis before December 2020, in Lyon, France; after radiographic exclusions, 82 patients were analyzed in each group. A third group of 80 short-stem prostheses (Aequalis Ascend Flex) implanted with short compactors was added for comparison. The angle of the humeral stem, diaphyseal and metaphyseal filling ratios, and distal cortical bone contact were evaluated.Results
The median absolute alignment deviation did not differ significantly between the 2 ARAMIS groups (short stem, 1.8°, range 0.0-6.3°; standard stem, 1.5°, range 0.0-6.6°; P = .07). Ninety-eight percent of standard stems and 91% of short stems were correctly aligned (<5°; P = .17). The mean proximal diaphyseal filling ratio was significantly lower in the short-stem group than in the standard-stem group (0.48 [0.08] vs. 0.55 [0.10]; P < .001). None of the short stems was classified as being at risk of diaphyseal press-fit fixation, compared with 13 standard-length stems (P < .001). By contrast, short stems implanted with short compactors were correctly aligned in only 51% of cases, and 61% had a diaphyseal filling ratio >0.7 (risk of press-fit fixation) vs. none of the ARAMIS short stems (P < .001). Distal endocortical contact was significantly more frequent in the standard-stem group (26% vs. 9%, P = .004). The Ascend comparison was non-randomized, non-contemporaneous, and involved a different implant, so the observed differences cannot be attributed to compactor length alone.Conclusion
In this group of shoulder arthroplasty patients, short-stem implants inserted with standard-length compactors did not show a significant difference in alignment compared with standard-length implants and had lower filling ratios and reduced endocortical contact. Short stems inserted with short compactors, by contrast, were frequently misaligned and filled the diaphysis, supporting the hypothesis that compactor length may be an important determinant of alignment and canal filling.
Related
- Temporary stent-post cinching to facilitate minimally invasive implantation of the Avalus aortic bioprosthesis
- Femoral Head-Preserving Porous Tantalum Implantation for Osteonecrosis of the Femoral Head: A Systematic Review and Meta-Analysis of Conversion to Total Hip Arthroplasty, Radiographic Progression, and Modes of Failure.
- Second Ray Pathologies Associated with Hallux Valgus: A Radiographic Comparative Study
- Conversational hypnosis versus standard of care to reduce anxiety in patients undergoing marker placement under radiographic control prior to breast cancer surgery: A randomized, multicenter trial
- Augmented and standard baseplates demonstrate similar clinical and radiographic outcomes following reverse shoulder arthroplasty with the Arthrex modular Glenoid System
BibTeX
@article{collotte2026standardlength,
title = {{Standard-length compactors facilitate anatomic implantation of short humeral stems: a comparative radiographic study}},
author = {Philippe Collotte and Stanislas Gunst and Jérome Vogels and Laurent Nové Josserand},
journal = {Journal of shoulder and elbow arthroplasty},
year = {2026},
month = sep,
doi = {10.1016/j.jsea.2026.100095},
url = {https://europepmc.org/article/PMC/PMC13753576},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Standard-length compactors facilitate anatomic implantation of short humeral stems: a comparative radiographic study
AU - Philippe Collotte
AU - Stanislas Gunst
AU - Jérome Vogels
AU - Laurent Nové Josserand
PY - 2026
DA - 2026/09/21
JO - Journal of shoulder and elbow arthroplasty
DO - 10.1016/j.jsea.2026.100095
UR - https://europepmc.org/article/PMC/PMC13753576
AB - Background To investigate in shoulder arthroplasty whether standard-length compactors can be used to insert short and standard-length stems along the anatomic axis of the humerus without excessive filling ratios and to compare short stems implanted with standard-length vs. short compactors.Methods A retrospective radiographic study was performed on patients who underwent shoulder arthroplasty with a short-stem ARAMIS prosthesis between December 2020 and December 2021 or with a standard-length ARAMIS prosthesis before December 2020, in Lyon, France; after radiographic exclusions, 82 patients were analyzed in each group. A third group of 80 short-stem prostheses (Aequalis Ascend Flex) implanted with short compactors was added for comparison. The angle of the humeral stem, diaphyseal and metaphyseal filling ratios, and distal cortical bone contact were evaluated.Results The median absolute alignment deviation did not differ significantly between the 2 ARAMIS groups (short stem, 1.8°, range 0.0-6.3°; standard stem, 1.5°, range 0.0-6.6°; P = .07). Ninety-eight percent of standard stems and 91% of short stems were correctly aligned (<5°; P = .17). The mean proximal diaphyseal filling ratio was significantly lower in the short-stem group than in the standard-stem group (0.48 [0.08] vs. 0.55 [0.10]; P < .001). None of the short stems was classified as being at risk of diaphyseal press-fit fixation, compared with 13 standard-length stems (P < .001). By contrast, short stems implanted with short compactors were correctly aligned in only 51% of cases, and 61% had a diaphyseal filling ratio >0.7 (risk of press-fit fixation) vs. none of the ARAMIS short stems (P < .001). Distal endocortical contact was significantly more frequent in the standard-stem group (26% vs. 9%, P = .004). The Ascend comparison was non-randomized, non-contemporaneous, and involved a different implant, so the observed differences cannot be attributed to compactor length alone.Conclusion In this group of shoulder arthroplasty patients, short-stem implants inserted with standard-length compactors did not show a significant difference in alignment compared with standard-length implants and had lower filling ratios and reduced endocortical contact. Short stems inserted with short compactors, by contrast, were frequently misaligned and filled the diaphysis, supporting the hypothesis that compactor length may be an important determinant of alignment and canal filling.
SN - 2471-5492
ER -