Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BYJournal of applied clinical medical physics

Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT.

  1. 1Northwell, New Hyde Park, New York, USA.
  2. 2Medical Physics Program, Physics and Astronomy, Hofstra University, Hempstead, New York, USA.

Abstract

Background

The dosimetric impact of hydrogel spacer in prostate cancer radiation therapy for reducing rectal radiation dose and mitigating toxicity has been well documented in the literature.Purpose

This study aimed to evaluate rectal dose sparing with hydrogel spacer placement in prostate cancer patients treated with External Beam Radiation Therapy (EBRT) across different fractionation schemes.Methods

A retrospective analysis was conducted on 254 patients: 179 patients received a hydrogel spacer, while 75 did not. Patients underwent EBRT with one of the following regimens: conventional fractionation (81 Gy in 45 fractions), hypofractionation (70 Gy in 28 fractions), or Stereotactic Body Radiotherapy (SBRT; 40 Gy in 5 fractions). To enable comparison across these schemes, volumetric doses for rectal wall (0.1, 0.5, 1, 2, 5, and 10 cm³) were calculated as Biological Effective Doses (BED) and subsequently converted to their Biological Equivalent Doses in 2 Gy fractions (EQD2).Results

Hydrogel spacer insertion significantly improved rectal dose sparing across all evaluated fractionation schemes (p < 0.01). For conventional fractionation group with spacer insertion, average rectal wall EQD2 was reduced by 13.0% to 51.4% across volumes ranging from 0.1 to 10 cm³. EQD2_max decreased by 7.4%, and EQD2_mean by 18.2%. In hypofractionation group, spacer placement led to rectal wall EQD2 reductions of 11.1% to 43.0% across the same volumes. EQD2_max decreased by 4.3%, and EQD2_mean by 21.5%. In SBRT, spacer insertion resulted in rectal wall EQD2 decreases of 17.7% to 40.8% for those volumes. Rectal wall EQD2_max and EQD2_mean were reduced by 6.3% and 22.5%, respectively. All reported reductions were statistically significant (p < 0.01).Conclusion

Hydrogel spacer insertion consistently and significantly improved rectal dose sparing for prostate cancer patients undergoing EBRT across all investigated fractionation schemes. Notably, more substantial dose reductions were observed in larger rectal wall volumes, indicating a greater protective benefit with increased tissue involvement.

Related

  1. Dosimetric Verification Using Tissue-Equivalent Phantoms
    Naayem Abdulraheem Salem Bakran, Ali Sid Ahmed Mohammed Ali, Al-Nazer Osman Mohammed Hamza +2
    Advances in Radiation OncologyPeer-reviewedCC BY-NC-ND 4.0Full textApplied physics & instrumentationPMC
  2. Preliminary Feasibility and Dosimetric Evaluation of Retroperitoneal Hydrogel Spacer Placement for Stereotactic Body Radiation Therapy: A Cadaveric Study
    Shin Tanabe, Kotaro Yoshio, Takaaki Komiyama +9
    Advances in Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  3. Exploratory machine-learning evaluation of clinical and dosimetric features in late prostate radiotherapy toxicity.
    Karl Jordan, Christopher J Talbot, John D Kelleher +2
    Clinical and translational radiation oncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMCPMC
  4. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  5. Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
    Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda +7
    arXivPreprintCC BY-NC-ND 4.0Full textBiological & medical physicsarXiv
BibTeX
@article{zhang2026biological,
  title = {{Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT.}},
  author = {Honglai Zhang and Jenghwa Chang and Jeffrey Antone and Louis Potters and Yijian Cao},
  journal = {Journal of applied clinical medical physics},
  year = {2026},
  month = nov,
  doi = {10.1002/acm2.70868},
  url = {https://europepmc.org/article/MED/43079722},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT.
AU  - Honglai Zhang
AU  - Jenghwa Chang
AU  - Jeffrey Antone
AU  - Louis Potters
AU  - Yijian Cao
PY  - 2026
DA  - 2026/11/26
JO  - Journal of applied clinical medical physics
DO  - 10.1002/acm2.70868
UR  - https://europepmc.org/article/MED/43079722
AB  - Background  The dosimetric impact of hydrogel spacer in prostate cancer radiation therapy for reducing rectal radiation dose and mitigating toxicity has been well documented in the literature.Purpose  This study aimed to evaluate rectal dose sparing with hydrogel spacer placement in prostate cancer patients treated with External Beam Radiation Therapy (EBRT) across different fractionation schemes.Methods  A retrospective analysis was conducted on 254 patients: 179 patients received a hydrogel spacer, while 75 did not. Patients underwent EBRT with one of the following regimens: conventional fractionation (81 Gy in 45 fractions), hypofractionation (70 Gy in 28 fractions), or Stereotactic Body Radiotherapy (SBRT; 40 Gy in 5 fractions). To enable comparison across these schemes, volumetric doses for rectal wall (0.1, 0.5, 1, 2, 5, and 10 cm³) were calculated as Biological Effective Doses (BED) and subsequently converted to their Biological Equivalent Doses in 2 Gy fractions (EQD2).Results  Hydrogel spacer insertion significantly improved rectal dose sparing across all evaluated fractionation schemes (p < 0.01). For conventional fractionation group with spacer insertion, average rectal wall EQD2 was reduced by 13.0% to 51.4% across volumes ranging from 0.1 to 10 cm³. EQD2_max decreased by 7.4%, and EQD2_mean by 18.2%. In hypofractionation group, spacer placement led to rectal wall EQD2 reductions of 11.1% to 43.0% across the same volumes. EQD2_max decreased by 4.3%, and EQD2_mean by 21.5%. In SBRT, spacer insertion resulted in rectal wall EQD2 decreases of 17.7% to 40.8% for those volumes. Rectal wall EQD2_max and EQD2_mean were reduced by 6.3% and 22.5%, respectively. All reported reductions were statistically significant (p < 0.01).Conclusion  Hydrogel spacer insertion consistently and significantly improved rectal dose sparing for prostate cancer patients undergoing EBRT across all investigated fractionation schemes. Notably, more substantial dose reductions were observed in larger rectal wall volumes, indicating a greater protective benefit with increased tissue involvement.
SN  - 1526-9914
ER  -