Dosimetric Verification Using Tissue-Equivalent Phantoms
4 affiliations
- 1Physiology Department, Medical Physics Unit, Faculty of Medicine & Health Sciences, Aden University, Aden, Yemen
- 2Biomedical Physics Department, Faculty of Science & Technology, Al Neelain University, Khartoum, Sudan
- 3Sudan University of Science & Technology, University of Medical Sciences & Technology, Department of Radiology, Khartoum, Sudan
- 4Medical Physics Unit, Radiation Oncology & Nuclear Medicine Department, National Cancer Institute, Cairo University, Cairo, Egypt
Abstract
Purpose: Treatment planning systems (TPSs) are critical for ensuring the safety and accuracy of radiation therapy. The International Atomic Energy Agency (IAEA) has developed comprehensive guidelines, such as Technical Reports Series No. 430 and the international Atomic Energy Agency (IAEA) Technical Document 1583 (TECDOC-1583), to support the dosimetric quality control and clinical validation of TPSs. This study aims to validate a TPS using the IAEA’s dosimetric quality assurance methodology and evaluates the feasibility and effectiveness of using locally developed phantoms as alternatives to commercially available phantoms for dosimetric verification of 3-dimensional conformal radiation therapy (3D-CRT) plans. This could provide a cost-effective solution for low-income countries, where the high cost of commercial phantoms can be a barrier.
Methods and Materials: An Elekta Versa HD linear accelerator operating at 6 MV and the Monaco TPS were employed in this study. Dose verification was performed using 3 different phantoms: a commercially available intensity modulated radiation therapy thorax phantom, a custom-made acrylic phantom, and a locally developed beeswax phantom. Supporting tools included an electron density phantom for computed tomography calibration and a calibrated ionization chamber for absolute dose measurements. All testing procedures adhered to IAEA protocols for evaluating dose distribution accuracy in 3D-CRT plans. A comprehensive comparison was conducted to assess the feasibility of using the locally fabricated phantoms as standalone verification tools.
Results: The TPS successfully passed the IAEA dosimetric test cases, with dose measurements generally falling within the IAEA’s ±4% tolerance limit. Both the acrylic and beeswax phantoms showed performance comparable to the commercial phantom, indicating their potential as effective, low-cost alternatives.
Conclusions: The IAEA test methodology effectively supports the validation of TPSs for 3D-CRT. The Monaco TPS demonstrated consistent accuracy across all 3 phantoms. Locally fabricated phantoms, particularly in resource-limited settings, can serve as practical and economical tools for TPS quality assurance when implemented in accordance with international guidelines.
Related
- Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT.
- Comparison of dosimetric verification results and plan complexity for treatment plans generated in Ethos 1.0 and Ethos 2.0 systems
- Replayable Monte Carlo MRI: From Persistent Tissue Microphysics to Queryable Virtual Phantoms
- Impact of CT image co-registration on dosimetric verification in ¹²⁵I seed implantation for lung cancer
- Comparative Radiobiological Evaluation of Radiotherapy Techniques Using Equivalent Uniform Dose, Tumor Control Probability, and Normal Tissue Complication Probability in Postmastectomy Breast Cancer
BibTeX
@article{bakran2026dosimetric,
title = {{Dosimetric Verification Using Tissue-Equivalent Phantoms}},
author = {Naayem Abdulraheem Salem Bakran and Ali Sid Ahmed Mohammed Ali and Al-Nazer Osman Mohammed Hamza and Maha Hassan Mokhtar and Nashaat Ahmed Deiab},
journal = {Advances in Radiation Oncology},
year = {2026},
month = sep,
doi = {10.1016/j.adro.2026.102217},
url = {https://doi.org/10.1016/j.adro.2026.102217},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Dosimetric Verification Using Tissue-Equivalent Phantoms
AU - Naayem Abdulraheem Salem Bakran
AU - Ali Sid Ahmed Mohammed Ali
AU - Al-Nazer Osman Mohammed Hamza
AU - Maha Hassan Mokhtar
AU - Nashaat Ahmed Deiab
PY - 2026
DA - 2026/09/18
JO - Advances in Radiation Oncology
DO - 10.1016/j.adro.2026.102217
UR - https://doi.org/10.1016/j.adro.2026.102217
AB - Purpose: Treatment planning systems (TPSs) are critical for ensuring the safety and accuracy of radiation therapy. The International Atomic Energy Agency (IAEA) has developed comprehensive guidelines, such as Technical Reports Series No. 430 and the international Atomic Energy Agency (IAEA) Technical Document 1583 (TECDOC-1583), to support the dosimetric quality control and clinical validation of TPSs. This study aims to validate a TPS using the IAEA’s dosimetric quality assurance methodology and evaluates the feasibility and effectiveness of using locally developed phantoms as alternatives to commercially available phantoms for dosimetric verification of 3-dimensional conformal radiation therapy (3D-CRT) plans. This could provide a cost-effective solution for low-income countries, where the high cost of commercial phantoms can be a barrier. Methods and Materials: An Elekta Versa HD linear accelerator operating at 6 MV and the Monaco TPS were employed in this study. Dose verification was performed using 3 different phantoms: a commercially available intensity modulated radiation therapy thorax phantom, a custom-made acrylic phantom, and a locally developed beeswax phantom. Supporting tools included an electron density phantom for computed tomography calibration and a calibrated ionization chamber for absolute dose measurements. All testing procedures adhered to IAEA protocols for evaluating dose distribution accuracy in 3D-CRT plans. A comprehensive comparison was conducted to assess the feasibility of using the locally fabricated phantoms as standalone verification tools. Results: The TPS successfully passed the IAEA dosimetric test cases, with dose measurements generally falling within the IAEA’s ±4% tolerance limit. Both the acrylic and beeswax phantoms showed performance comparable to the commercial phantom, indicating their potential as effective, low-cost alternatives. Conclusions: The IAEA test methodology effectively supports the validation of TPSs for 3D-CRT. The Monaco TPS demonstrated consistent accuracy across all 3 phantoms. Locally fabricated phantoms, particularly in resource-limited settings, can serve as practical and economical tools for TPS quality assurance when implemented in accordance with international guidelines.
SN - 2452-1094
ER -