A rare cause of dysfunction of mechanical aortic valve prosthesis in a young adult

  1. 1Sofiamed University Hospital

Abstract

A mechanical prosthetic valve dysfunction carries a high risk of hospitalization and patient death. It may show up as stenosis of the valve prosthesis or intra/paraprosthetic regurgitation. Prosthetic stenosis, in turn, may be caused by granulation tissue (pannus), thrombosis, a combination of pannus and thrombosis, a prosthesis mechanical defect, or a unique surgical technique. Establishing the specific cause of prosthetic stenosis is of crucial importance for the therapeutic behavior. Prosthetic thrombosis requires conservative intensification of anticoagulation/fibrinolysis or surgical treatment in an accelerated/emergency manner. When the cause of the thrombosis is pannus, a mechanical defect, or surgical technique, the only treatment option is cardiac surgical reintervention. The manifestation of granulation tissue (pannus) is indicative of a non-immune reaction to the prosthetic valve and suture material following prosthetic valve replacement. The basis of this phenomenon is the growth of fibroelastic tissue associated with an increase in the expression of transforming growth factor beta.[1] In a small proportion of patients with implanted prosthetic valves, the growth of pannus leads to subvalvular obstruction of blood flow and results in prosthetic stenosis. Despite the technological advancements in imaging diagnostics, visualizing pannus remains challenging and not always feasible. Consequently, we employ a multifaceted approach that incorporates anamnestic, clinical, and imaging methods to reach a diagnosis. Operative exploration is the only method by which definitive confirmation can be obtained. The objective of this article was twofold: first, to present a rare case of stenosis of a mechanical aortic valve prosthesis due to a circumferential shaft of granulation tissue (pannus) forming a kind of de novo subaortic membrane; and second, to outline an algorithm for the diagnosis of prosthetic valve stenosis and differential diagnosis between thrombosis and pannus as the cause of valve dysfunction. The following case study presents a patient who met the surgical treatment indications due to stenosis of a mechanical aortic valve prosthesis. The clinical information and imaging studies indicated that the prosthetic dysfunction was likely due to the presence of granulation tissue (pannus). The intraoperative finding revealed a circumferential shaft of granulation tissue, forming a novel subaortic membrane.

Related

  1. Experimental study of TPU and SEBS additively manufactured leaflets for novel aortic valve polymer TAVI prosthesis
    Alex G. Kuchumov, Denis Khoroshev, Aleksandra Kutuzova +7
    Frontiers in Bioengineering and BiotechnologyPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  2. Real-time three-dimensional echocardiographic assessment of the association between aortic diameter and left ventricular mechanical dyssynchrony in patients with bicuspid aortic valve
    Huan Liu, Xueting Guo, Kunxuan Liu +7
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  3. Coexisting Moderate-to-Severe Tricuspid Regurgitation and Renal Dysfunction Identify a High-Risk Group After Transcatheter Aortic Valve Replacement
    Philipp Lauten, Birgit Markus, Georgios Chatzis +4
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Durability of a novel mechanical aortic valve closure technique during left ventricular assist device support: A comparative case report.
    Yuji Shiozaki, Yuki Ichihara, Saeko Yoshizawa +2
    JHLT openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  5. Coronary microvascular dysfunction in patients undergoing transcatheter aortic valve implantation: A systematic review and meta-analysis
    Maethas Panyawongkhanti, Peerawat Chintrakulchai, Chonthicha Tanking +1
    PLOS OnePeer-reviewedCC BY 4.0Full textSystems & synthetic biologyStatisticsPLOS
BibTeX
@article{dimitrov2026rare,
  title = {{A rare cause of dysfunction of mechanical aortic valve prosthesis in a young adult}},
  author = {Todor Dimitrov and Ivilin Todorov},
  journal = {Folia Medica},
  year = {2026},
  month = oct,
  doi = {10.3897/folmed.67.e165032},
  url = {https://doi.org/10.3897/folmed.67.e165032},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - A rare cause of dysfunction of mechanical aortic valve prosthesis in a young adult
AU  - Todor Dimitrov
AU  - Ivilin Todorov
PY  - 2026
DA  - 2026/10/01
JO  - Folia Medica
DO  - 10.3897/folmed.67.e165032
UR  - https://doi.org/10.3897/folmed.67.e165032
AB  - A mechanical prosthetic valve dysfunction carries a high risk of hospitalization and patient death. It may show up as stenosis of the valve prosthesis or intra/paraprosthetic regurgitation. Prosthetic stenosis, in turn, may be caused by granulation tissue (pannus), thrombosis, a combination of pannus and thrombosis, a prosthesis mechanical defect, or a unique surgical technique. Establishing the specific cause of prosthetic stenosis is of crucial importance for the therapeutic behavior. Prosthetic thrombosis requires conservative intensification of anticoagulation/fibrinolysis or surgical treatment in an accelerated/emergency manner. When the cause of the thrombosis is pannus, a mechanical defect, or surgical technique, the only treatment option is cardiac surgical reintervention. The manifestation of granulation tissue (pannus) is indicative of a non-immune reaction to the prosthetic valve and suture material following prosthetic valve replacement. The basis of this phenomenon is the growth of fibroelastic tissue associated with an increase in the expression of transforming growth factor beta.[1] In a small proportion of patients with implanted prosthetic valves, the growth of pannus leads to subvalvular obstruction of blood flow and results in prosthetic stenosis. Despite the technological advancements in imaging diagnostics, visualizing pannus remains challenging and not always feasible. Consequently, we employ a multifaceted approach that incorporates anamnestic, clinical, and imaging methods to reach a diagnosis. Operative exploration is the only method by which definitive confirmation can be obtained. The objective of this article was twofold: first, to present a rare case of stenosis of a mechanical aortic valve prosthesis due to a circumferential shaft of granulation tissue (pannus) forming a kind of de novo subaortic membrane; and second, to outline an algorithm for the diagnosis of prosthetic valve stenosis and differential diagnosis between thrombosis and pannus as the cause of valve dysfunction. The following case study presents a patient who met the surgical treatment indications due to stenosis of a mechanical aortic valve prosthesis. The clinical information and imaging studies indicated that the prosthetic dysfunction was likely due to the presence of granulation tissue (pannus). The intraoperative finding revealed a circumferential shaft of granulation tissue, forming a novel subaortic membrane.
SN  - 1314-2143
SN  - 0204-8043
ER  -