Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYJournal of imaging

Source- and Geometry-Dependent Spatial Profiles in Commercial Bioluminescence Imaging: Experimental Comparison and Geant4 Simulations.

  1. 1Institute of Experimental Physics and Center for Free-Electron Laser Science (CFEL), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany.
  2. 2Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany.
  3. 3Leibniz Institute of Virology, Martinistraße 52/N 63, 20251 Hamburg, Germany.

Abstract

In this study, we investigated the transfer of a previously established LED-based Geant4 optical-photon simulation framework to experimental bioluminescence imaging (BLI) using two commercial imaging systems. An IVIS 200 and a SmART+ BLI/CT system were used to compare spatial intensity profiles obtained from a controlled LED source and ATP-driven bioluminescence under defined phantom conditions. Direct comparison demonstrated broader spatial profiles for BLI than for LED emission, with the magnitude of the differences varying between imaging systems. To investigate the transferability of the simulation framework, a spatially extended, isotropically emitting BLI source was implemented in Geant4, including its aqueous volume and sample container. At a phantom thickness of 2.00 mm, the simulations reproduced the general characteristics of the normalized experimental BLI profiles, although the simulated spatial profiles were consistently narrower than those measured experimentally. Separate idealized two-point-source simulations were used to investigate spatial separability under controlled phantom conditions, while additional simulations demonstrated that the source-to-boundary distance influences spatial-profile formation through changes in photon entry conditions and scattering histories. Overall, these findings demonstrate the potential of source-specific Monte Carlo simulations to investigate spatial photon transport in commercial BLI systems and to support the design and optimization of experimental studies through systematic evaluation of source and phantom parameters, potentially reducing the need for extensive experimental test series.

Related

  1. Comparison of Commercial Fixed and In-House Tissue-Based and Live Cell-Based Assays for the Detection of Common Neuronal Surface Autoantibodies
    Elif Şanlı, Zerrin Karaaslan, Cem İsmail Küçükali +17
    Archives of NeuropsychiatryPeer-reviewedLicence not statedFull textNeurologyPMC
  2. Process-dependent Analytical Differences Among Commercial Botulinum Neurotoxin Type A Formulations
    Hyunjung Choi, Se Na Kim, Chang Ki Lee +4
    Plastic and reconstructive surgery. Global openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Standardization and Development of Spray-Dried Chewable Tablets From the Traditional Thai Remedy "Ya-Tard Aob-Choei": HPLC Analysis and Comparison With Commercial Products.
    Jringjai Areemit, Bungorn Sripanidkulchai, Sasipong Tipratchadaporn +1
    Advances in pharmacological and pharmaceutical sciencesPeer-reviewedCC BYFull textPharmacology & toxicologyEurope PMC
  4. Budget Impact of Adopting Office-Based Ultrasound-Guided Carpal Tunnel Release: A Commercial Claims Cost-Comparison Study.
    Orrin I Franko, James M Saucedo, Richard B Schaefer +2
    ClinicoEconomics and outcomes research : CEORPeer-reviewedCC BY-NCFull textNeurologyEurope PMCPMC
  5. Solvent-Dependent Monomer Leaching From Two Commercial Dental Resin Composites: A Time-Dependent Elution Behaviour
    Vidushi Gilhotra, Rahul Banerjee, Ajay Chhabra +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
BibTeX
@article{karstens2026source,
  title = {{Source- and Geometry-Dependent Spatial Profiles in Commercial Bioluminescence Imaging: Experimental Comparison and Geant4 Simulations.}},
  author = {Tim Karstens and Thorsten Frenzel and Antonina Wrzeszcz and Theresa Staufer and Florian Grüner},
  journal = {Journal of imaging},
  year = {2026},
  month = oct,
  doi = {10.3390/jimaging12110530},
  url = {https://europepmc.org/article/MED/43082921},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Source- and Geometry-Dependent Spatial Profiles in Commercial Bioluminescence Imaging: Experimental Comparison and Geant4 Simulations.
AU  - Tim Karstens
AU  - Thorsten Frenzel
AU  - Antonina Wrzeszcz
AU  - Theresa Staufer
AU  - Florian Grüner
PY  - 2026
DA  - 2026/10/25
JO  - Journal of imaging
DO  - 10.3390/jimaging12110530
UR  - https://europepmc.org/article/MED/43082921
AB  - In this study, we investigated the transfer of a previously established LED-based Geant4 optical-photon simulation framework to experimental bioluminescence imaging (BLI) using two commercial imaging systems. An IVIS 200 and a SmART+ BLI/CT system were used to compare spatial intensity profiles obtained from a controlled LED source and ATP-driven bioluminescence under defined phantom conditions. Direct comparison demonstrated broader spatial profiles for BLI than for LED emission, with the magnitude of the differences varying between imaging systems. To investigate the transferability of the simulation framework, a spatially extended, isotropically emitting BLI source was implemented in Geant4, including its aqueous volume and sample container. At a phantom thickness of 2.00 mm, the simulations reproduced the general characteristics of the normalized experimental BLI profiles, although the simulated spatial profiles were consistently narrower than those measured experimentally. Separate idealized two-point-source simulations were used to investigate spatial separability under controlled phantom conditions, while additional simulations demonstrated that the source-to-boundary distance influences spatial-profile formation through changes in photon entry conditions and scattering histories. Overall, these findings demonstrate the potential of source-specific Monte Carlo simulations to investigate spatial photon transport in commercial BLI systems and to support the design and optimization of experimental studies through systematic evaluation of source and phantom parameters, potentially reducing the need for extensive experimental test series.
SN  - 2313-433X
ER  -