Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 28 min ago
PreprintCC BY 4.0HAL

Hemodynamic insights into TIPS intervention for portal hypertension management: a comprehensive computational study

Abstract

The Transjugular Intrahepatic Portosystemic Shunt (TIPS) is a well-established treatment for complications of portal hypertension in liver cirrhosis, effectively reducing the portal pressure gradient (PPG) and improving transplant-free survival. However, excessive shunting, particularly with larger graft diameters, may increase systemic ammonia levels, predisposing patients to hepatic encephalopathy, and may also precipitate cardiac complications. Computational modelling may therefore eventually serve as a predictive tool for patient selection and pre-procedural planning. In this study, patient-specific TIPS geometries were segmented from CT images and analyzed using computational fluid dynamics with physiologically grounded boundary conditions, before and after TIPS placement. Liver volumetry, hematocrit-dependent blood viscosity, and clinically measured pre-TIPS pressure gradients were incorporated within a coupled 3D–0D multiscale framework. We systematically evaluated the influence of shunt diameter (6–10 mm), puncture location (right, left portal branches and portal bifurcation), angulation, inflow distribution, and outflow partitioning on portal hemodynamics. Results show that the hemodynamic response varies substantially with shunt configuration and patient-specific parameters. Modulating diameter produces a clear trade-off between portal decompression and overshunting. Shunt position, length, and angulation influence PPG only mildly through changes in effective shunt resistance and alter the proportion of TIPS flow originating from the superior mesenteric vein by not more than 10% across configurations. Furthermore, hepatofugal and hepatopetal flow states are mechanistically reproduced, and are governed by the balance between TIPS, intrahepatic portal and sinusoidal-hepatic venous resistances. Overall, this study provides an integrated and physiologically informed framework for understanding and optimizing TIPS configuration in a patient-specific manner.

Related

  1. Société de Biomécanique senior investigator award 2024—Hemodynamic performance of a bicuspid venous valve: A computational study
    Barthelemy Thibaud, Simon Mendez, Franck Nicoud
    Journal of BiomechanicsPeer-reviewedCC BY 4.0Full textGeneral biologyCardiovascular medicineHAL
  2. Artificial intelligence-based surrogate modeling of hemodynamic indicators in abdominal aortic aneurysms using computational fluid dynamics
    MyeungHye Suh, Up Huh, Chiseung Lee
    PLOS OnePeer-reviewedCC BYFull textGeneral biologyGeometry & topologyPLOSEurope PMCPMC
  3. Comprehensive motion management for liver SBRT on a 1.5 T MR-Linac: Initial clinical experience and dosimetric comparison with an ITV-based workflow
    Monica Lo Russo, Simon Böke, David Mönnich +8
    Clinical and Translational Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  4. A physics-informed peripheral hemodynamic digital twin for personalized estimation of arterial stiffness
    Arian Aghilinejad, Alessio Tamborini, Faisal Amlani +1
    npj Digital MedicinePeer-reviewedCC BYFull textSystems & synthetic biologyNumerical analysis & scientific computingHAL
  5. A novel vortex generator for enhancing bileaflet mechanical heart valve performance proposed through detailed hemodynamic and data-driven dynamic mode decomposition studies
    A. Chauhan, C. Sasmal
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
BibTeX
@misc{varsos2026hemodynamic,
  title = {{Hemodynamic insights into TIPS intervention for portal hypertension management: a comprehensive computational study}},
  author = {Pavlos Varsos and Friederike Schäfer and Cristina Ripoll and Nicolas Golse and Irene E Vignon-Clementel},
  howpublished = {HAL},
  year = {2026},
  month = sep,
  doi = {10.1016/j.compbiomed.2026.111909},
  url = {https://hal.science/hal-05630883v2},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Hemodynamic insights into TIPS intervention for portal hypertension management: a comprehensive computational study
AU  - Pavlos Varsos
AU  - Friederike Schäfer
AU  - Cristina Ripoll
AU  - Nicolas Golse
AU  - Irene E Vignon-Clementel
PY  - 2026
DA  - 2026/09/30
PB  - HAL
DO  - 10.1016/j.compbiomed.2026.111909
UR  - https://hal.science/hal-05630883v2
AB  - The Transjugular Intrahepatic Portosystemic Shunt (TIPS) is a well-established treatment for complications of portal hypertension in liver cirrhosis, effectively reducing the portal pressure gradient (PPG) and improving transplant-free survival. However, excessive shunting, particularly with larger graft diameters, may increase systemic ammonia levels, predisposing patients to hepatic encephalopathy, and may also precipitate cardiac complications. Computational modelling may therefore eventually serve as a predictive tool for patient selection and pre-procedural planning. In this study, patient-specific TIPS geometries were segmented from CT images and analyzed using computational fluid dynamics with physiologically grounded boundary conditions, before and after TIPS placement. Liver volumetry, hematocrit-dependent blood viscosity, and clinically measured pre-TIPS pressure gradients were incorporated within a coupled 3D–0D multiscale framework. We systematically evaluated the influence of shunt diameter (6–10 mm), puncture location (right, left portal branches and portal bifurcation), angulation, inflow distribution, and outflow partitioning on portal hemodynamics. Results show that the hemodynamic response varies substantially with shunt configuration and patient-specific parameters. Modulating diameter produces a clear trade-off between portal decompression and overshunting. Shunt position, length, and angulation influence PPG only mildly through changes in effective shunt resistance and alter the proportion of TIPS flow originating from the superior mesenteric vein by not more than 10% across configurations. Furthermore, hepatofugal and hepatopetal flow states are mechanistically reproduced, and are governed by the balance between TIPS, intrahepatic portal and sinusoidal-hepatic venous resistances. Overall, this study provides an integrated and physiologically informed framework for understanding and optimizing TIPS configuration in a patient-specific manner.
ER  -