Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BYVeterinary sciences

Establishment of Recombinase-Aided Amplification Combined with Lateral Flow Dipstick for Rapid Detection of Yersinia pestis Based on the pla Gene.

  1. 1Key Laboratory of Animal Disease and Human Health of Sichuan, College of Veterinary Medicine, Sichuan Agricultural University, Chengdu 611130, China.
  2. 2College of Veterinary Medicine, Northwest A&F University, Yangling 712100, China.

Abstract

This study establishes a rapid detection method for Yersinia pestis that combines recombinase-aided amplification with a lateral flow dipstick (RAA-LFD) and targets the pla gene. Based on the pla gene sequences of six representative strains from NCBI, three primer pairs (P-F1/R1, P-F2/R2, and P-F3/R3) and one RAA-nfo probe were designed. The RAA-LFD assay was constructed and evaluated for sensitivity, specificity, repeatability, and clinical applicability. Initial screening via polymerase chain reaction followed by agarose gel electrophoresis (PCR-AGE) showed P-F3/R3 produced a faint band, while P-F1/R1 and P-F2/R2 yielded bright, specific bands. RAA-LFD condition optimization demonstrated that: clear test lines (T lines) were observable at primer concentrations of 250-2000 nM, with the strongest signal at 2000 nM; the T line signal of P-F1/R1 remained stable at 35-41 °C, peaking slightly at 39 °C, whereas P-F2/R2 decreased markedly at 35 °C (p < 0.01); and the integrated optical density (IOD) of the T line increased with reaction time from 5 to 30 min, with a significant difference between 5 and 30 min (p < 0.001). The optimal reaction conditions were consequently determined as follows: primer pair P-F1/R1, a final primer concentration of 2000 nM, and incubation at 39 °C for 30 min. All five Y. pestis strains tested positive, while seven non-target strains and blank controls were negative, consistent with PCR results. Regarding sensitivity, the limit of detection (LOD) of RAA-LFD was 3.8 × 10² copies/μL, approximately 10-fold lower than conventional PCR (3.8 × 10³ copies/μL). In the repeatability evaluation, intra-assay CVs were 1.79%, 0.59%, and 7.76%; inter-assay CVs were 1.75%, 2.35%, and 1.70%, all within 10%. Results for 130 clinical samples showed 100% agreement with PCR and qPCR. RAA-LFD established in this study provides a reliable, simple approach for on-site plague screening and primary laboratory diagnosis.

Related

  1. Detection and identification of Neisseria subflava in saliva stains using recombinant polymerase amplification combined with lateral flow dipstick
    Xue Li, Chudong Wang, Shuyu Liu +4
    Frontiers in MicrobiologyPeer-reviewedCC BY 4.0MicrobiologyFrontiersCrossref
  2. Development of loop-mediated isothermal amplification (LAMP) combined with a lateral flow dipstick DNA biosensor for detection of α thalassemia 1 [Southeast Asia (SEA), --SEA deletion]
    Jutturong Ckumdee, Sataron Karnjanaopas, Duantida Songdej +4
    PLOS OnePeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationGenetics & genomicsPLOS
  3. Construction of an infectious clone of tomato leaf curl New Delhi virus and development of a duplex assay through recombinase polymerase amplification-lateral flow dipstick to detect the virus and tomato yellow leaf curl virus simultaneously
    Ning Qiao, Yuxing Chen, Yao Meng +6
    Frontiers in microbiologyPeer-reviewedCC BYFull textPlant biologyEurope PMCCrossref
  4. Rapid Detection of Klebsiella pneumoniae in Infants With Severe Infection Disease by Instant Nanofluorescent Microspheres-Immunochromatography Combined With Recombinase Polymerase Isothermal Amplification Technology.
    Yiping Liu, Yi Lu, Xin Wang +7
    Journal of clinical laboratory analysisPeer-reviewedCC BYFull textEurope PMC
  5. Development of a Rapid, Sensitive, and Visual Recombinase-Aided Amplification Combined with Pyrococcus furiosus Argonaute (RAA-PfAgo) Assay for Sex Identification in Swinhoe’s Pheasant (Lophura swinhoii)
    Tongtong Zhan, Fanrong Liu, Huan Zhang +10
    Current issues in molecular biologyPeer-reviewedCC BYFull textEurope PMC
BibTeX
@article{zhou2026establishment,
  title = {{Establishment of Recombinase-Aided Amplification Combined with Lateral Flow Dipstick for Rapid Detection of Yersinia pestis Based on the pla Gene.}},
  author = {Yunhan Zhou and Xue Yang and Ziling Ding and Qiuyu Fan and Xiaofang Yan and Haifeng Liu and Ziyao Zhou and Zhijun Zhong and Jialiang Xin and Guangneng Peng},
  journal = {Veterinary sciences},
  year = {2026},
  month = oct,
  doi = {10.3390/vetsci13101091},
  url = {https://europepmc.org/article/MED/42944185},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Establishment of Recombinase-Aided Amplification Combined with Lateral Flow Dipstick for Rapid Detection of Yersinia pestis Based on the pla Gene.
AU  - Yunhan Zhou
AU  - Xue Yang
AU  - Ziling Ding
AU  - Qiuyu Fan
AU  - Xiaofang Yan
AU  - Haifeng Liu
AU  - Ziyao Zhou
AU  - Zhijun Zhong
AU  - Jialiang Xin
AU  - Guangneng Peng
PY  - 2026
DA  - 2026/10/14
JO  - Veterinary sciences
DO  - 10.3390/vetsci13101091
UR  - https://europepmc.org/article/MED/42944185
AB  - This study establishes a rapid detection method for Yersinia pestis that combines recombinase-aided amplification with a lateral flow dipstick (RAA-LFD) and targets the pla gene. Based on the pla gene sequences of six representative strains from NCBI, three primer pairs (P-F1/R1, P-F2/R2, and P-F3/R3) and one RAA-nfo probe were designed. The RAA-LFD assay was constructed and evaluated for sensitivity, specificity, repeatability, and clinical applicability. Initial screening via polymerase chain reaction followed by agarose gel electrophoresis (PCR-AGE) showed P-F3/R3 produced a faint band, while P-F1/R1 and P-F2/R2 yielded bright, specific bands. RAA-LFD condition optimization demonstrated that: clear test lines (T lines) were observable at primer concentrations of 250-2000 nM, with the strongest signal at 2000 nM; the T line signal of P-F1/R1 remained stable at 35-41 °C, peaking slightly at 39 °C, whereas P-F2/R2 decreased markedly at 35 °C (p < 0.01); and the integrated optical density (IOD) of the T line increased with reaction time from 5 to 30 min, with a significant difference between 5 and 30 min (p < 0.001). The optimal reaction conditions were consequently determined as follows: primer pair P-F1/R1, a final primer concentration of 2000 nM, and incubation at 39 °C for 30 min. All five Y. pestis strains tested positive, while seven non-target strains and blank controls were negative, consistent with PCR results. Regarding sensitivity, the limit of detection (LOD) of RAA-LFD was 3.8 × 10² copies/μL, approximately 10-fold lower than conventional PCR (3.8 × 10³ copies/μL). In the repeatability evaluation, intra-assay CVs were 1.79%, 0.59%, and 7.76%; inter-assay CVs were 1.75%, 2.35%, and 1.70%, all within 10%. Results for 130 clinical samples showed 100% agreement with PCR and qPCR. RAA-LFD established in this study provides a reliable, simple approach for on-site plague screening and primary laboratory diagnosis.
SN  - 2306-7381
ER  -