Skip to content
DraconiticResearch
Search Sources API
194,226 studies31 sourcesUpdated 55 min ago
PreprintarXiv licencearXiv

Magnet-Free Proton Therapy with 4D Pencil Beam Delivery Optimisation

Abstract

Objective. Motion management is a critical challenge in proton therapy for mobile tumours. This study aims to develop and evaluate a novel four-dimensional (4D) pencil beam delivery strategy that incorporates respiratory motion into a dynamic treatment plan to improve dose conformity and treatment efficiency. Approach. To assess this 4D pencil beam delivery strategy, a mobile phantom was used. The generated 4D treatment plans were assessed with various scanner configurations, including gantry-free and magnet-free scanner heads. For each setup, the treatment time, dose conformity, and robustness against irregular breathing patterns were quantified. The influence of scanner head design and patient-specific motion irregularities on overall plan quality was evaluated. Main Results. The 4D planning tool generated treatment plans that achieved clinically acceptable dose distributions across all configurations. In magnet-free configurations, static beam operation substantially increased treatment time and reduced dose conformity. In contrast, configurations using a single scanner magnet, without a gantry, maintained acceptable conformity within practical treatment times. Significance. The proposed 4D delivery strategy demonstrates feasibility for treating mobile targets with simplified, gantry-free and magnet-free scanner designs. Further improvements could be achieved by synchronising the patient's breathing with 4D delivery, which may enhance dose accuracy during irregular or interrupted breathing. By reducing system complexity while preserving dosimetric performance, this approach offers a pathway toward more accessible and cost-effective proton beam therapy for motion-affected tumours.

Versions

Related

  1. PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation
    Lukas Zimmermann, Hermann Fuchs, Attila Simkó +1
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  2. End-to-end film-based characterization of gated delivery latencies in a spot-scanned synchrotron-based proton therapy system.
    Z S Stottler, J J Kruse, A J Deisher
    Journal of applied clinical medical physicsPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  3. Cardio-respiratory-gated proton pencil beam scanning for cardiac ablation: workflow and end-to-end validation
    Nicolas Depauw, Felicitas Bijari, Ethan Cascio +16
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossrefDOAJ
  4. Clinical Commissioning of the First Ultra-Compact Gantry-less Upright Proton Therapy System
    Serdar Charyyev, Adam Johansson, Zhuoran Jiang +17
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  5. Can future reirradiation justify upfront proton therapy? An extension of model-based proton therapy selection beyond primary-course NTCP benefit
    Nathan Torelli, Jan Unkelbach
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
BibTeX
@misc{muehlenen2026magnetfree,
  title = {{Magnet-Free Proton Therapy with 4D Pencil Beam Delivery Optimisation}},
  author = {Nair N von Muehlenen and Florentin Bieder and Ye Zhang and Philippe C Cattin},
  howpublished = {arXiv},
  year = {2026},
  month = jun,
  doi = {10.48550/arxiv.2606.03562},
  eprint = {2606.03562},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2606.03562},
}
RIS
TY  - UNPB
TI  - Magnet-Free Proton Therapy with 4D Pencil Beam Delivery Optimisation
AU  - Nair N von Muehlenen
AU  - Florentin Bieder
AU  - Ye Zhang
AU  - Philippe C Cattin
PY  - 2026
DA  - 2026/06/02
PB  - arXiv
DO  - 10.48550/arxiv.2606.03562
UR  - https://arxiv.org/abs/2606.03562
AB  - Objective. Motion management is a critical challenge in proton therapy for mobile tumours. This study aims to develop and evaluate a novel four-dimensional (4D) pencil beam delivery strategy that incorporates respiratory motion into a dynamic treatment plan to improve dose conformity and treatment efficiency. Approach. To assess this 4D pencil beam delivery strategy, a mobile phantom was used. The generated 4D treatment plans were assessed with various scanner configurations, including gantry-free and magnet-free scanner heads. For each setup, the treatment time, dose conformity, and robustness against irregular breathing patterns were quantified. The influence of scanner head design and patient-specific motion irregularities on overall plan quality was evaluated. Main Results. The 4D planning tool generated treatment plans that achieved clinically acceptable dose distributions across all configurations. In magnet-free configurations, static beam operation substantially increased treatment time and reduced dose conformity. In contrast, configurations using a single scanner magnet, without a gantry, maintained acceptable conformity within practical treatment times. Significance. The proposed 4D delivery strategy demonstrates feasibility for treating mobile targets with simplified, gantry-free and magnet-free scanner designs. Further improvements could be achieved by synchronising the patient's breathing with 4D delivery, which may enhance dose accuracy during irregular or interrupted breathing. By reducing system complexity while preserving dosimetric performance, this approach offers a pathway toward more accessible and cost-effective proton beam therapy for motion-affected tumours.
ER  -