Skip to content
DraconiticResearch
Search Sources API
190,851 studies31 sourcesUpdated 34 min ago
Peer-reviewedCC BY-NC-NDACS measurement science au

An Oxygen-Sensitive Phosphorescent Probe for the Determination of l‑Ascorbic Acid in Serum.

  1. 1Key Laboratory for Advanced Materials, Shanghai Key Laboratory of Functional Materials Chemistry, Feringa Nobel Prize Scientist Joint Research Center, Frontiers Science Center for Materiobiology & Dynamic Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China.
  2. 2Guangdong Basic Research Center of Excellence for Aggregate Science, School of Science and Engineering, The Chinese University of Hong Kong (Shenzhen), Longgang, Shenzhen, Guangdong 518172, China.
  3. 3Chongqing Key Laboratory for the Mechanism and Intervention of Cancer Metastasis, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, China.

Abstract

The level of l-ascorbic acid (AA) in serum reflects biological nutritional status and antioxidant defense capacity, while also indicating the severity of chronic wasting diseases such as malignancy or inflammation. Accurate detection of AA in serum samples is therefore critical for disease diagnosis and health monitoring. However, conventional methods suffer from several drawbacks, including severe matrix interference and complex pretreatment procedures. Herein, we present a stable phosphorescent probe, constructed from aluminum/pyromellitic acid phosphorescent materials (Al/PMA-PMs), for the sensitive detection of AA in complex biological matrices, obviating the need for any pretreatment. The Al/PMA-PMs exhibit strong blue room-temperature phosphorescence (RTP) in the dry state; upon dispersion in water, they show a prolonged lifetime (from 479.72 to 1073.55 ms) and a red-shifted emission (from 447 to 535 nm). The redshift is attributed to a reduced degree of polymerization, while the water stability stems from the strong Al³⁺-PMA coordination, which restricts molecular motion and suppresses nonradiative quenching. Importantly, the addition of AA effectively enhances the RTP intensity of Al/PMA-PMs by virtue of its high oxygen-scavenging ability, yielding a linear detection range of 0.1-10 μM and a detection limit of 66 nM. Owing to their strong anti-interference capability, the probe enables direct and accurate determination of AA in the serum of both healthy subjects and cancer patients, with excellent recoveries. Furthermore, serum samples validation against liquid chromatograph-mass spectrometer confirms the probe's accuracy and reliability, giving a correlation coefficient of 0.995 and demonstrating good agreement between the two methods. This work develops a water-stable phosphorescent probe that enables sensitive and practical AA detection in complex serum samples, providing a promising strategy for monitoring disease progression in cancer patients.

Related

  1. New Oxygen Sensor with Polyaniline Spin Probe and Low Frequency EPR (L-Band) Detection System
    Mikołaj Baranowski, Sebastian Golczak, Jerzy J. Langer
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  2. A Sensitive Approach for the Determination of the Novel Antidepressant Vilazodone: Electrochemical Sensing Using a Boron‐Doped Diamond Electrode in Surfactant‐Containing Media
    Birdem Bersu İlvan, Ipek Kucuk, Selenay Sadak +2
    ChemistryOpenPeer-reviewedCC BY 4.0Full textElectrochemistry & energyCrossrefEurope PMCDOAJ
  3. A miniaturized drop-based three-electrode system for sensitive electrochemical determination of azathioprine using pencil graphite
    Ali Rasi Mahmoudi, Mehrdad Abbasi Mahmoudabad, Karim Asadpour-Zeynali
    Scientific ReportsPeer-reviewedCC BY 4.0Full textElectrochemistry & energyCrossref
  4. Highly sensitive square-wave anodic stripping voltammetry at H-terminated BDD for ultra-trace fomesafen determination in water and soil
    André F. Pereira, Christiano C. de Matos, Ricardo F. Brocenschi +1
    Talanta OpenPeer-reviewedCC BYFull textElectrochemistry & energyDOAJ
  5. Oxygen-Unaffected Temperature Sensing in Air-Saturated Aqueous Dispersion with Oxygen-Sensitive Luminescent Metal Complexes Encapsulated in l‑Arginine-Type Silica Networks.
    Viktoriia Osipova, Christian Homann, Arne C Weber +7
    ACS measurement science auPeer-reviewedCC BYFull textMaterials & polymersEurope PMC
BibTeX
@article{liang2026oxygensensitive,
  title = {{An Oxygen-Sensitive Phosphorescent Probe for the Determination of l‑Ascorbic Acid in Serum.}},
  author = {Li Ya Liang and Ya Ting Gao and Ruo Can Qian and Mengli Liu and Bin Bin Chen and Da Wei Li and Yongpeng He},
  journal = {ACS measurement science au},
  year = {2026},
  month = sep,
  doi = {10.1021/acsmeasuresciau.6c00195},
  url = {https://europepmc.org/article/MED/42921134},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - An Oxygen-Sensitive Phosphorescent Probe for the Determination of l‑Ascorbic Acid in Serum.
AU  - Li Ya Liang
AU  - Ya Ting Gao
AU  - Ruo Can Qian
AU  - Mengli Liu
AU  - Bin Bin Chen
AU  - Da Wei Li
AU  - Yongpeng He
PY  - 2026
DA  - 2026/09/22
JO  - ACS measurement science au
DO  - 10.1021/acsmeasuresciau.6c00195
UR  - https://europepmc.org/article/MED/42921134
AB  - The level of l-ascorbic acid (AA) in serum reflects biological nutritional status and antioxidant defense capacity, while also indicating the severity of chronic wasting diseases such as malignancy or inflammation. Accurate detection of AA in serum samples is therefore critical for disease diagnosis and health monitoring. However, conventional methods suffer from several drawbacks, including severe matrix interference and complex pretreatment procedures. Herein, we present a stable phosphorescent probe, constructed from aluminum/pyromellitic acid phosphorescent materials (Al/PMA-PMs), for the sensitive detection of AA in complex biological matrices, obviating the need for any pretreatment. The Al/PMA-PMs exhibit strong blue room-temperature phosphorescence (RTP) in the dry state; upon dispersion in water, they show a prolonged lifetime (from 479.72 to 1073.55 ms) and a red-shifted emission (from 447 to 535 nm). The redshift is attributed to a reduced degree of polymerization, while the water stability stems from the strong Al³⁺-PMA coordination, which restricts molecular motion and suppresses nonradiative quenching. Importantly, the addition of AA effectively enhances the RTP intensity of Al/PMA-PMs by virtue of its high oxygen-scavenging ability, yielding a linear detection range of 0.1-10 μM and a detection limit of 66 nM. Owing to their strong anti-interference capability, the probe enables direct and accurate determination of AA in the serum of both healthy subjects and cancer patients, with excellent recoveries. Furthermore, serum samples validation against liquid chromatograph-mass spectrometer confirms the probe's accuracy and reliability, giving a correlation coefficient of 0.995 and demonstrating good agreement between the two methods. This work develops a water-stable phosphorescent probe that enables sensitive and practical AA detection in complex serum samples, providing a promising strategy for monitoring disease progression in cancer patients.
SN  - 2694-250X
ER  -