Skip to content
DraconiticResearch
Search Sources API
197,688 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BY-NC-NDBMC ophthalmology

Evaluation of Bruch's membrane opening minimum rim width and retinal nerve fiber layer in patients with glaucoma and comparison with normal population.

  1. 1Department of Ophthalmology, Bartın State Hospital, Bartın, 74100, Turkey. [email protected].
  2. 2Department of Ophthalmology, Istanbul Medipol University, Camlica Hospital Eye Clinic, Uskudar, Istanbul, Turkiye, 34696, Turkey.

Abstract

Purpose

To assess and compare the diagnostic performance of Bruch's membrane opening-minimum rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness parameters in patients with early-stage glaucoma.Material and method

This observational cross-sectional study included 60 eyes with primary open-angle glaucoma, 44 eyes with ocular hypertension (OHT), and 41 healthy control eyes. One eye per participant was randomly selected. All subjects underwent comprehensive ophthalmologic evaluation, including Goldmann applanation tonometry, gonioscopy, standard automated perimetry, spectral-domain optical coherence tomography, and dilated fundus examination. Global and sectoral RNFL thickness measurements, including standard and Anatomical Positioning System-based RNFL (APS-RNFL), as well as BMO-MRW parameters, were obtained using the Glaucoma Module Premium Edition (GMPE). Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC) globally and across six Garway-Heath sectors.Results

For discrimination between glaucoma and healthy controls, global BMO-MRW demonstrated satisfactory diagnostic performance comparable to APS-RNFL, with AUROC values of 0.783 (95% CI: 0.690-0.859) and 0.827 (95% CI: 0.739-0.895), respectively. The highest AUROC for APS-RNFL was observed in the inferotemporal sector (0.810), while BMO-MRW showed its highest performance in the superotemporal sector (0.800), with no significant difference between the two parameters. BMO-MRW exhibited consistently good diagnostic accuracy across all sectors, whereas APS-RNFL demonstrated reduced performance in the superonasal, nasal, and inferonasal sectors (AUROC <0.7). In differentiating OHT from healthy controls, global BMO-MRW outperformed APS-RNFL (AUROC: 0.625 vs. 0.504).Conclusions

BMO-MRW is a reliable and effective parameter for the early diagnosis of glaucoma, showing consistent global and sectoral diagnostic performance compared with APS-RNFL.

Related

  1. Evaluation of the Perimouse Online Suprathreshold Visual Field Test for Glaucoma Screening in a Chinese Population: A Comparison with the Humphrey Field Analyzer.
    Xiaoyuan Shen, Zidong Chen, Kaixin Tan +6
    Clinical ophthalmology (Auckland, N.Z.)Peer-reviewedCC BY-NCFull textGeneral medicineEurope PMCPMC
  2. Comparison of the Melbourne rapid fields-web device-independent online perimeter and the octopus 600 perimeter in glaucoma patients
    George Y. X. Kong, Algis Vingrys, Manisha Ambawat +4
    Frontiers in OphthalmologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  3. Glaucoma and Diabetes Mellitus: A Comparative Evaluation of Comorbid Effect on Tear Quantity among Patients in Owerri, Imo State, Nigeria.
    C. M. Chukwuoha, G. Ovenseri-Ogbomo, Y. C. Azuamah +7
    medRxivPreprintCC BY-NC-NDFull textEpidemiology & public healthmedRxiv
  4. Automatic transesophageal echocardiographic evaluation of patients with mitral valve prolapse: comparison with patients without structural cardiac chamber remodeling (an exploratory study)
    Marcelo Luiz Campos Vieira, Ana C. T. Rodrigues, Edgar Daminello +17
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Development and Population-Based Prognostic Utility Assessment of an ICD-10-CM-Based Prediction Model to Identify Left Ventricular Systolic Dysfunction: Discrimination Performance and Population-Based Evaluation in 83,357 Patients with Acute Coronary Syndrome
    Andreea Eunice Cosa, Marc Llagostera Martin, Sílvia Jovells-Vaqué +13
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{davas2026evaluation,
  title = {{Evaluation of Bruch's membrane opening minimum rim width and retinal nerve fiber layer in patients with glaucoma and comparison with normal population.}},
  author = {Mustafa Davas and Halit Oguz},
  journal = {BMC ophthalmology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12886-026-05194-w},
  url = {https://europepmc.org/article/MED/42968078},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Evaluation of Bruch's membrane opening minimum rim width and retinal nerve fiber layer in patients with glaucoma and comparison with normal population.
AU  - Mustafa Davas
AU  - Halit Oguz
PY  - 2026
DA  - 2026/08/05
JO  - BMC ophthalmology
DO  - 10.1186/s12886-026-05194-w
UR  - https://europepmc.org/article/MED/42968078
AB  - Purpose  To assess and compare the diagnostic performance of Bruch's membrane opening-minimum rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness parameters in patients with early-stage glaucoma.Material and method  This observational cross-sectional study included 60 eyes with primary open-angle glaucoma, 44 eyes with ocular hypertension (OHT), and 41 healthy control eyes. One eye per participant was randomly selected. All subjects underwent comprehensive ophthalmologic evaluation, including Goldmann applanation tonometry, gonioscopy, standard automated perimetry, spectral-domain optical coherence tomography, and dilated fundus examination. Global and sectoral RNFL thickness measurements, including standard and Anatomical Positioning System-based RNFL (APS-RNFL), as well as BMO-MRW parameters, were obtained using the Glaucoma Module Premium Edition (GMPE). Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC) globally and across six Garway-Heath sectors.Results  For discrimination between glaucoma and healthy controls, global BMO-MRW demonstrated satisfactory diagnostic performance comparable to APS-RNFL, with AUROC values of 0.783 (95% CI: 0.690-0.859) and 0.827 (95% CI: 0.739-0.895), respectively. The highest AUROC for APS-RNFL was observed in the inferotemporal sector (0.810), while BMO-MRW showed its highest performance in the superotemporal sector (0.800), with no significant difference between the two parameters. BMO-MRW exhibited consistently good diagnostic accuracy across all sectors, whereas APS-RNFL demonstrated reduced performance in the superonasal, nasal, and inferonasal sectors (AUROC <0.7). In differentiating OHT from healthy controls, global BMO-MRW outperformed APS-RNFL (AUROC: 0.625 vs. 0.504).Conclusions  BMO-MRW is a reliable and effective parameter for the early diagnosis of glaucoma, showing consistent global and sectoral diagnostic performance compared with APS-RNFL.
SN  - 1471-2415
ER  -