Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 41 min ago
Peer-reviewedCC BY 4.0Surgical Endoscopy

Implementation of a single-port robotic platform into your colorectal surgery practice: a SAGES colorectal committee task force review of evolving robotic technology and innovations

4 more authors
13 affiliations
  1. 1Department of Surgery, UC Davis Medical Center, 6th Floor, 2335 Stockton Blvd., Sacramento, CA 95817 USA
  2. 2Department of Surgery, Florida Atlantic University, Boca Raton, FL USA
  3. 3Department of Surgery, UC Davis Medical Center, Sacramento, CA USA
  4. 4School of Medicine, University of Arizona, Phoenix, AZ USA
  5. 5Department of Colorectal Surgery, MultiCare Cancer Institute, Tacoma, WA USA
  6. 6Department of Surgery, Los Angeles Medical Center, Kaiser Permanente, Los Angeles, CA USA
  7. 7International School Reduced Scar Laparoscopy, University of Mons, Mons, Belgium
  8. 8Minimally Invasive General and Oncologic Surgery, Humanitas Gavazzeni and Castelli University Hospital, Bergamo, Italy
  9. 9Kadlec Regional Medical Center and Elison S. Floyed College of Medicine, Washington State University, Richland, WA USA
  10. 10Department of Surgery, Mayo Clinic, Rochester, MN USA
  11. 11Department of Surgery, Army Medical Center, Tacoma, WA USA
  12. 12Department of Surgery Division of Colon and Rectal Surgery, Houston Methodist Hospital, Houston, TX USA
  13. 13Department of Surgery, Mount Sinai Health System, New York, NY USA

Abstract

Background: Robotic and endoscopic techniques continue to revolutionize minimally invasive surgery. Single-port (SP) robotic platforms mark a new era in minimally invasive colorectal surgery, combining single-incision/site access with full robotic articulation through a single access point. This manuscript, as a part of a four-part series, outlines specific technical considerations of the SP robotic platform including details of the platform, instrumentation, docking, and operative maneuvers.

Methods: Subject matter experts from the SAGES Colorectal Committee SP Task Force performed a structured review of the currently FDA-approved SP robotic platform, assessing technical features, instrumentation, and workflow considerations for several key representative operations relevant to colorectal surgery. Three clinical areas of SP implementation included transanal robotic surgery, right colectomy, and low anterior resection (LAR). Task Force members (subject matter experts with early experience in SP robotic platforms) analyzed technical details, patient selection, and operative workflows. Representative procedural techniques were detailed with emphasis on instrumentation choice, docking strategies, and key operative steps specific to single-port colorectal surgery.

Results: The technical aspects of the SP platform include full robotic articulation through a single 25 mm port. A SP approach also enables triangulation and dexterity within confined spaces using three wristed instruments and a flexible 3-D camera. The current 360-degree boom rotation facilitates multi-quadrant manipulation without redocking. Current limitations may include continued reliance on bedside assistance for certain energy and stapling operative steps, although stapling capability has expanded with FDA clearance of an SP-compatible 45 mm stapler as of April 2025. Training of the entire operative team and gradual progression of case complexity is recommended as the surgeon implements this new technology into clinical practice.

Conclusions: A SP robotic approach to minimally invasive colorectal surgical procedures is feasible for a range of colorectal surgery operations. In select procedures like SP TAMIS, SP right colectomy, and SP-LAR, the single-port platform appears to offer advantages related to reduced invasiveness and improved surgeon ergonomics compared to other minimally invasive approaches. Successful implementation requires structured training, careful patient selection, and adherence to evidence-based adoption principles.

Related

  1. A focus group study on citizens’ perspectives on the ethics of health technology innovations: “Where will they take us?”
    Jelena Vanhollebeke, Chris Gastmans, Tijs Vandemeulebroucke +1
    BMC Medical EthicsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthPMC
  2. Microarray patches for transdermal drug delivery: a critical narrative review of technological innovations, CMC challenges, clinical translation, and global health implementation
    Priyabrata Pattnaik, Lawrence Sena Tuglo, Mohammed Alissa +7
    Journal of Pharmacy & Pharmaceutical SciencesPeer-reviewedCC BYFull textPharmacology & toxicologyDOAJ
  3. Competency Based Education in Anesthesia and Intensive Care Medicine: Educational Innovations, Implementation Challenges, and Future Directions
    Ibrahim Abdullahi Mohamed, Najma Abdullahi Mohamed
    Advances in Medical Education and PracticePeer-reviewedCC BY-NC 4.0Full textEpidemiology & public healthPMCEurope PMC
  4. Flipped classroom and technology-enhanced learning in dermatology education: evidence, implementation, and future directions
    Meng Zhang, Ruiqi Chu, Shengni Zhang +2
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Colorectal cancer surveillance in Lynch syndrome: quality standards, emerging technology and complementary strategies.
    Joaquín Castillo-Iturra, Evelien Dekker, Francesc Balaguer
    Familial cancerPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{sarin2026implementation,
  title = {{Implementation of a single-port robotic platform into your colorectal surgery practice: a SAGES colorectal committee task force review of evolving robotic technology and innovations}},
  author = {Ankit Sarin and Justin Dourado and Christopher M. Seffren and Upinder S. Sidhu and Poya Pourghaderi and Nathan Aminpour and Elisabeth C. McLemore and Giovanni Dapri and Nawar A. Alkhamesi and Sherief Shawki and Brooklyn Williams and Muhammed Elhadi and Scott Nguyen and Alison Wenholz and Patricia Sylla and Laila Rashidi},
  journal = {Surgical Endoscopy},
  year = {2026},
  month = oct,
  doi = {10.1007/s00464-026-13471-4},
  url = {https://doi.org/10.1007/s00464-026-13471-4},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Implementation of a single-port robotic platform into your colorectal surgery practice: a SAGES colorectal committee task force review of evolving robotic technology and innovations
AU  - Ankit Sarin
AU  - Justin Dourado
AU  - Christopher M. Seffren
AU  - Upinder S. Sidhu
AU  - Poya Pourghaderi
AU  - Nathan Aminpour
AU  - Elisabeth C. McLemore
AU  - Giovanni Dapri
AU  - Nawar A. Alkhamesi
AU  - Sherief Shawki
AU  - Brooklyn Williams
AU  - Muhammed Elhadi
AU  - Scott Nguyen
AU  - Alison Wenholz
AU  - Patricia Sylla
AU  - Laila Rashidi
PY  - 2026
DA  - 2026/10/12
JO  - Surgical Endoscopy
DO  - 10.1007/s00464-026-13471-4
UR  - https://doi.org/10.1007/s00464-026-13471-4
AB  - Background: Robotic and endoscopic techniques continue to revolutionize minimally invasive surgery. Single-port (SP) robotic platforms mark a new era in minimally invasive colorectal surgery, combining single-incision/site access with full robotic articulation through a single access point. This manuscript, as a part of a four-part series, outlines specific technical considerations of the SP robotic platform including details of the platform, instrumentation, docking, and operative maneuvers.  Methods: Subject matter experts from the SAGES Colorectal Committee SP Task Force performed a structured review of the currently FDA-approved SP robotic platform, assessing technical features, instrumentation, and workflow considerations for several key representative operations relevant to colorectal surgery. Three clinical areas of SP implementation included transanal robotic surgery, right colectomy, and low anterior resection (LAR). Task Force members (subject matter experts with early experience in SP robotic platforms) analyzed technical details, patient selection, and operative workflows. Representative procedural techniques were detailed with emphasis on instrumentation choice, docking strategies, and key operative steps specific to single-port colorectal surgery.  Results: The technical aspects of the SP platform include full robotic articulation through a single 25 mm port. A SP approach also enables triangulation and dexterity within confined spaces using three wristed instruments and a flexible 3-D camera. The current 360-degree boom rotation facilitates multi-quadrant manipulation without redocking. Current limitations may include continued reliance on bedside assistance for certain energy and stapling operative steps, although stapling capability has expanded with FDA clearance of an SP-compatible 45 mm stapler as of April 2025. Training of the entire operative team and gradual progression of case complexity is recommended as the surgeon implements this new technology into clinical practice.  Conclusions: A SP robotic approach to minimally invasive colorectal surgical procedures is feasible for a range of colorectal surgery operations. In select procedures like SP TAMIS, SP right colectomy, and SP-LAR, the single-port platform appears to offer advantages related to reduced invasiveness and improved surgeon ergonomics compared to other minimally invasive approaches. Successful implementation requires structured training, careful patient selection, and adherence to evidence-based adoption principles.
SN  - 0930-2794
SN  - 1432-2218
ER  -