Peanut Shell-Derived Biochar Paste Electrode for Electrochemical Detection of Doxorubicin in Aqueous Solution
4 affiliations
- 1Doctoral School, “Victor Babes” University of Medicine and Pharmacy, Eftimie Murgu Square, No. 2, 300041 Timisoara, Romania
- 2“Coriolan Dragulescu” Institute of Chemistry, Romanian Academy, 24 Mihai Viteazu Bvd., 300223 Timisoara, Romania
- 3Condensed Matter Department, National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania
- 4Department of Applied Chemistry and Engineering of Inorganic Compounds and Environment, Politehnica University of Timisoara, Blv. Vasile Parvan No. 6, 300223 Timisoara, Romania
Abstract
Doxorubicin (DOX), from cytostatic class of pharmaceuticals, is an anthracycline widely used in treatments of several forms of cancers, which cause it to be present in various matrices of water, e.g., hospital effluents, wastewater treatment plants, surface water and tap water with significant concentrations. Electrochemical methods using carbon-based electrodes are known as common electrode materials applied in electroanalysis, and biochar obtained by pyrolysis of vegetable waste represents a greener alternative in electrochemical detection. In this work, biochar obtained from peanut shells by pyrolysis at 550 °C with low O2 content, activated with KOH under a N2-controlled atmosphere at 700 °C, was characterized morpho-structurally by XRD, SEM, AFM, RAMAN and FTIR spectroscopy. Comparative characterization of biochar (BC) and multi-walled carbon nanotube (CNT) paste electrodes was achieved by cyclic voltammetry in 0.1 M Na2SO4 supporting electrolyte and the presence of DOX for its detection. Higher sensitivity for DOX detection was found at BC (16.8 µA/mg∙L−1∙cm−2 at a detection potential of 0.014 V/SCE) in comparison with CNT (3.34 µA/mg∙L−1∙cm−2 at a detection potential of 0.225 V/SCE) by cyclic voltammetry. The DOX detection limit of 0.006 µM was achieved on the BC electrode using square-wave voltammetry, which is similar or better in comparison with certain reported carbon-based electrodes.
Related
- Scalable Multiplexed Electrochemical Aptasensor Enabled by Chitosan for Heavy Metal Ion Detection: Advancing Electrode Functionalization and Reusability
- Tetrahedral DNA nanostructure–gated solution-phase CRISPR/Cas12a system for probe immobilization-free, reagent-efficient, and dual-phase electrochemical detection of circulating microRNAs in liquid biopsy
- A Solution-Gated Graphene Transistor Sensor for the Detection and Quantification of Guanine Quadruplexes.
- A Dual-Mode Electrochemical Aptasensor for Ochratoxin A Detection in Red Wine Based on a Target-Induced Displacement Strategy
- Detection of Food Contaminants Based on Dual‐Mode Electrochemical and Optical Aptasensors: A Review
BibTeX
@article{stoia2026peanut,
title = {{Peanut Shell-Derived Biochar Paste Electrode for Electrochemical Detection of Doxorubicin in Aqueous Solution}},
author = {Silvia Stoia and Sorina Ilies and Mina Ionela Morariu and Anamaria Baciu and Mircea Nicolaescu and Cornelia Bandas and Carmen Lazau and Corina Orha and Florica Manea},
journal = {International Journal of Molecular Sciences},
year = {2026},
month = nov,
doi = {10.3390/ijms272310724},
url = {https://www.mdpi.com/1422-0067/27/23/10724},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Peanut Shell-Derived Biochar Paste Electrode for Electrochemical Detection of Doxorubicin in Aqueous Solution
AU - Silvia Stoia
AU - Sorina Ilies
AU - Mina Ionela Morariu
AU - Anamaria Baciu
AU - Mircea Nicolaescu
AU - Cornelia Bandas
AU - Carmen Lazau
AU - Corina Orha
AU - Florica Manea
PY - 2026
DA - 2026/11/26
JO - International Journal of Molecular Sciences
DO - 10.3390/ijms272310724
UR - https://www.mdpi.com/1422-0067/27/23/10724
AB - Doxorubicin (DOX), from cytostatic class of pharmaceuticals, is an anthracycline widely used in treatments of several forms of cancers, which cause it to be present in various matrices of water, e.g., hospital effluents, wastewater treatment plants, surface water and tap water with significant concentrations. Electrochemical methods using carbon-based electrodes are known as common electrode materials applied in electroanalysis, and biochar obtained by pyrolysis of vegetable waste represents a greener alternative in electrochemical detection. In this work, biochar obtained from peanut shells by pyrolysis at 550 °C with low O2 content, activated with KOH under a N2-controlled atmosphere at 700 °C, was characterized morpho-structurally by XRD, SEM, AFM, RAMAN and FTIR spectroscopy. Comparative characterization of biochar (BC) and multi-walled carbon nanotube (CNT) paste electrodes was achieved by cyclic voltammetry in 0.1 M Na2SO4 supporting electrolyte and the presence of DOX for its detection. Higher sensitivity for DOX detection was found at BC (16.8 µA/mg∙L−1∙cm−2 at a detection potential of 0.014 V/SCE) in comparison with CNT (3.34 µA/mg∙L−1∙cm−2 at a detection potential of 0.225 V/SCE) by cyclic voltammetry. The DOX detection limit of 0.006 µM was achieved on the BC electrode using square-wave voltammetry, which is similar or better in comparison with certain reported carbon-based electrodes.
SN - 1422-0067
ER -