Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BYFoot & Ankle Orthopaedics

Sustainable Diagnostics: A Comparative Analysis of Radiation, Carbon Emissions, and the Cost of Weightbearing CT, Radiography, and Standard CT in Weber B Ankle Fracture Imaging; a Short Report

  1. 1Foot & Ankle Research and Innovation Laboratory (FARIL), Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA
  2. 2Foot and Ankle Division, Department of Orthopaedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA

Abstract

Background : As value-based care and sustainability increasingly shape clinical practice, foot and ankle imaging must balance diagnostic efficacy, patient safety, environmental impact, and cost. However, few studies have calculated and compared lower-extremity radiographs (XR), standard lower-extremity computed tomography (CT), and weightbearing CT (WBCT) across radiation, cost, and carbon emissions. We aimed to compare radiation exposure, procedural cost, and carbon emissions across XR, CT, and WBCT. Methods: This retrospective chart review assessed 25 WBCTs, 25 CTs, and 25 XRs from adults evaluated for Weber B ankle fractures with congruent mortise. Radiation exposure was calculated from dosage reports and compared with pairwise tests. Scanner electricity use values (both measured and literature derived) estimated carbon emissions. Costs were determined by time-driven activity-based costing (TDABC). Results: With the numbers available, no significant difference in radiation could be detected between WBCT and XR (0.004 [IQR 0.004-0.004] vs 0.003 [IQR 0.002-0.005] mSv, P = .12), but both were lower than CT ( P < .001). WBCT showed intermediate costs ($28.14) and carbon emissions (0.07 kg CO 2 e) compared with XR ($13.98, 0.06 kg CO 2 e) and CT ($37.79, 0.30 kg CO 2 e) the lowest cost and carbon emissions compared with CT and WBCT. Standard CT had the highest values across modalities. Conclusion: Although XR remains a favorable preliminary imaging option, WBCT’s lower radiation dose, cost, and carbon emissions compared with CT may support considering WBCT as an advanced imaging alternative to standard CT in adults with Weber B ankle fractures and a congruent mortise, where WBCT is available. Level of Evidence: Level III, retrospective comparative study.

Related

  1. Body Size, Radiation Dose and Exposure Index in Conventional Radiography: A Multicentre Prospective Study
    Manuel Duarte Lobo, Sérgio Miravent, Rui Pereira de Almeida
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Mobile radiation shielding device for scatter dose reduction during portable radiography in an orthopedic ward
    Jongwat Cheewakul, Natee Ina, Suphalak Khamruang Marshall +1
    PLOS OnePeer-reviewedCC BY 4.0PhysiologyPLOS
  3. Development and validation of a pregnant phantom with adjustable fetal presentation for region-specific fetal radiation dose assessment during pelvic radiography.
    Yuta Matsunaga, Yumi Kataoka, Koichi Chida +1
    Journal of applied clinical medical physicsPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  4. Comparative Evaluation of Cone-Beam Computed Tomography (CBCT) and Panoramic Radiography for Presurgical Implant Planning in the Posterior Mandible: A Retrospective Analysis
    Sowmiya Elango, Varun Muthuraman, Sri Sahana Ilango +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMCEurope PMCPMC
  5. Weightbearing CT in the Evaluation of Athletic Foot and Ankle Injuries
    Julieta Brué, Lolita Micicoi, Cesar de Cesar Netto
    Current Reviews in Musculoskeletal MedicinePeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
BibTeX
@article{luk2026sustainable,
  title = {{Sustainable Diagnostics: A Comparative Analysis of Radiation, Carbon Emissions, and the Cost of Weightbearing CT, Radiography, and Standard CT in Weber B Ankle Fracture Imaging; a Short Report}},
  author = {Justin Luk BS and Robin Hu BS and Julia Remlinger BS and Rohith Ryali BA and Mani Eftekhari BS and Soheil Ashkani-Esfahani MD, MPH and Eric M. Bluman MD, PhD and Jeremy T. Smith MD},
  journal = {Foot \& Ankle Orthopaedics},
  year = {2026},
  month = nov,
  doi = {10.1177/24730114261504445},
  url = {https://doi.org/10.1177/24730114261504445},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Sustainable Diagnostics: A Comparative Analysis of Radiation, Carbon Emissions, and the Cost of Weightbearing CT, Radiography, and Standard CT in Weber B Ankle Fracture Imaging; a Short Report
AU  - Justin Luk BS
AU  - Robin Hu BS
AU  - Julia Remlinger BS
AU  - Rohith Ryali BA
AU  - Mani Eftekhari BS
AU  - Soheil Ashkani-Esfahani MD, MPH
AU  - Eric M. Bluman MD, PhD
AU  - Jeremy T. Smith MD
PY  - 2026
DA  - 2026/11/19
JO  - Foot & Ankle Orthopaedics
DO  - 10.1177/24730114261504445
UR  - https://doi.org/10.1177/24730114261504445
AB  - Background : As value-based care and sustainability increasingly shape clinical practice, foot and ankle imaging must balance diagnostic efficacy, patient safety, environmental impact, and cost. However, few studies have calculated and compared lower-extremity radiographs (XR), standard lower-extremity computed tomography (CT), and weightbearing CT (WBCT) across radiation, cost, and carbon emissions. We aimed to compare radiation exposure, procedural cost, and carbon emissions across XR, CT, and WBCT. Methods: This retrospective chart review assessed 25 WBCTs, 25 CTs, and 25 XRs from adults evaluated for Weber B ankle fractures with congruent mortise. Radiation exposure was calculated from dosage reports and compared with pairwise tests. Scanner electricity use values (both measured and literature derived) estimated carbon emissions. Costs were determined by time-driven activity-based costing (TDABC). Results: With the numbers available, no significant difference in radiation could be detected between WBCT and XR (0.004 [IQR 0.004-0.004] vs 0.003 [IQR 0.002-0.005] mSv, P = .12), but both were lower than CT ( P < .001). WBCT showed intermediate costs ($28.14) and carbon emissions (0.07 kg CO 2 e) compared with XR ($13.98, 0.06 kg CO 2 e) and CT ($37.79, 0.30 kg CO 2 e) the lowest cost and carbon emissions compared with CT and WBCT. Standard CT had the highest values across modalities. Conclusion: Although XR remains a favorable preliminary imaging option, WBCT’s lower radiation dose, cost, and carbon emissions compared with CT may support considering WBCT as an advanced imaging alternative to standard CT in adults with Weber B ankle fractures and a congruent mortise, where WBCT is available. Level of Evidence: Level III, retrospective comparative study.
SN  - 2473-0114
ER  -