Development of a real-time FPGA-based CNN trigger operating on full-granularity calorimeter images
Abstract
We present a real-time field-programmable gate array (FPGA) implementation of a convolutional neural network (CNN) for event classification on full calorimeter images that retain crystal-level shower information. To meet the resource and latency constraints of trigger electronics, the network parameters and hidden activations were quantized to 8 bits with quantization-aware training, and a lossless space-to-depth reorganization rearranged the input image into fewer spatial positions, reducing the estimated CNN inference latency by more than an order of magnitude. The approach was evaluated with the J-PARC KOTO detector, recorded data, and data-acquisition (DAQ) constraints as a benchmark, targeting the online separation of the rare K0L→π0e+e− decay from its dominant K0L→π+π−π0 background. As a proof of principle, the firmware was implemented and validated on an AMD Versal Premium VPK120 evaluation board. On 100,000 test events, inference on the board rejected (99.34±0.04)% of the recorded background sample enriched in K0L→π+π−π0 decays at a nominal K0L→π0e+e− efficiency of 95%, with a measured CNN inference latency of 17.9 μs. Combining the measured image-assembly and CNN inference latencies with the estimated link-transfer and score-return times gives a projected end-to-end latency of 25.9 μs, within the adopted 32 μs DAQ latency budget. These results demonstrate the feasibility of using full-granularity calorimeter images for CNN-based event selection that achieves high background rejection while keeping the trigger latency within tens of microseconds.
Related
- Real-Time SiPM Pulse Deconvolution for a High-granularity Dual-readout Calorimeter with Neutral Networks
- Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectors
- Using Graph Neural Networks for the segmentation of overlapping objects in high granularity calorimeters
- End-to-end Particle Reconstruction with Transformers in High-Granularity Calorimeters
- Design and Simulation Study of the Hadronic Calorimeter for the EicC Zero Degree Calorimeter
BibTeX
@misc{wu2026development,
title = {{Development of a real-time FPGA-based CNN trigger operating on full-granularity calorimeter images}},
author = {Jia-Jen Wu and Yun-Tsung Lai and Yu-Chen Tung and Sin-Ting Chen and Yu-Sheng Liu},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.36720},
eprint = {2610.36720},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.36720},
}
RIS
TY - UNPB
TI - Development of a real-time FPGA-based CNN trigger operating on full-granularity calorimeter images
AU - Jia-Jen Wu
AU - Yun-Tsung Lai
AU - Yu-Chen Tung
AU - Sin-Ting Chen
AU - Yu-Sheng Liu
PY - 2026
DA - 2026/10/27
PB - arXiv
DO - 10.48550/arxiv.2610.36720
UR - https://arxiv.org/abs/2610.36720
AB - We present a real-time field-programmable gate array (FPGA) implementation of a convolutional neural network (CNN) for event classification on full calorimeter images that retain crystal-level shower information. To meet the resource and latency constraints of trigger electronics, the network parameters and hidden activations were quantized to 8 bits with quantization-aware training, and a lossless space-to-depth reorganization rearranged the input image into fewer spatial positions, reducing the estimated CNN inference latency by more than an order of magnitude. The approach was evaluated with the J-PARC KOTO detector, recorded data, and data-acquisition (DAQ) constraints as a benchmark, targeting the online separation of the rare K^0_L→π^0e^+e^− decay from its dominant K^0_L→π^+π^−π^0 background. As a proof of principle, the firmware was implemented and validated on an AMD Versal Premium VPK120 evaluation board. On 100,000 test events, inference on the board rejected (99.34±0.04)% of the recorded background sample enriched in K^0_L→π^+π^−π^0 decays at a nominal K^0_L→π^0e^+e^− efficiency of 95%, with a measured CNN inference latency of 17.9 μs. Combining the measured image-assembly and CNN inference latencies with the estimated link-transfer and score-return times gives a projected end-to-end latency of 25.9 μs, within the adopted 32 μs DAQ latency budget. These results demonstrate the feasibility of using full-granularity calorimeter images for CNN-based event selection that achieves high background rejection while keeping the trigger latency within tens of microseconds.
ER -