Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)
Abstract
This paper investigates the physical characteristics of the liquid Trimethyl-Bismuth (TMBi) relevant for charge readout in potential TMBi filled detectors for Positron-Emission-Tomography (PET) instruments. The high photo-efficiency and the possibility of fast timing by detection of Cherenkov light created in the liquid are both favorable for use of TMBi in a PET system. However, to obtain a high position and energy resolution also a readout of the charge signal created due to the absorption of a 511 keV photon is required. For this purpose the liquid has to be clean of electro-negative and ionic impurities. A distillation technique was developed within this study as one of the possible methods to remove such impurities and a measurement on the efficiency of this cleaning method is provided. The relevant quantities for an efficient charge readout are the free ion yield and the electron mobility of the liquid. We report on a new measurement of the zero-field free ion yield in TMBi and, using that result, produce an estimate of the electron mobility. The rather low zero-field free ion yield and its much lower expected electron mobility compared to tetramethyl-n compounds like TMSi question the use of the trimethyl molecule TMBi for a PET detector liquid. But we are also giving arguments that the tetramethyl molecule TMPb could be an interesting alternative.
Related
- Assessment of AlGaN channel high-electron mobility transistors on silicon for high-temperature power electronics
- Comment on arXiv:2608.29450: "First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale"
- Improvement of Electron Cyclotron Emission Radiometer Towards Real-Time Temperature Measurement in the WEST tokamak
- Thomson Scattering Measurement of 1 keV Electron Temperature on Lawson Machine 26
- First Measurement of Differential Cross Sections in Kinematic Imbalance Variables with Electron Neutrino Interactions Using the MicroBooNE Detector
BibTeX
@misc{gerke2026measurement,
title = {{Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)}},
author = {B. Gerke and V. Hannen and S. Peters and C. Huhmann and V. Sharyy and D. Yvon and K. Schäfers and C. Weinheimer},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.13564},
eprint = {2610.13564},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.13564},
}
RIS
TY - UNPB
TI - Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)
AU - B. Gerke
AU - V. Hannen
AU - S. Peters
AU - C. Huhmann
AU - V. Sharyy
AU - D. Yvon
AU - K. Schäfers
AU - C. Weinheimer
PY - 2026
DA - 2026/10/09
PB - arXiv
DO - 10.48550/arxiv.2610.13564
UR - https://arxiv.org/abs/2610.13564
AB - This paper investigates the physical characteristics of the liquid Trimethyl-Bismuth (TMBi) relevant for charge readout in potential TMBi filled detectors for Positron-Emission-Tomography (PET) instruments. The high photo-efficiency and the possibility of fast timing by detection of Cherenkov light created in the liquid are both favorable for use of TMBi in a PET system. However, to obtain a high position and energy resolution also a readout of the charge signal created due to the absorption of a 511 keV photon is required. For this purpose the liquid has to be clean of electro-negative and ionic impurities. A distillation technique was developed within this study as one of the possible methods to remove such impurities and a measurement on the efficiency of this cleaning method is provided. The relevant quantities for an efficient charge readout are the free ion yield and the electron mobility of the liquid. We report on a new measurement of the zero-field free ion yield in TMBi and, using that result, produce an estimate of the electron mobility. The rather low zero-field free ion yield and its much lower expected electron mobility compared to tetramethyl-n compounds like TMSi question the use of the trimethyl molecule TMBi for a PET detector liquid. But we are also giving arguments that the tetramethyl molecule TMPb could be an interesting alternative.
ER -