Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY-NC 4.0Radiation Protection Dosimetry

Environmental monitoring of static magnetic fields around operating high-voltage direct-current transmission facilities in Japan

Abstract

Static magnetic fields are present around high-voltage direct-current transmission facilities, but on-land environmental measurement data under actual operating conditions remain limited. This study measured three-axis magnetic flux densities at 1.0 m above ground at 38 accessible locations around all four operating direct-current transmission links in Japan, including overhead-line and underground-cable sections. Resultant magnetic flux densities ranged from 39.7 to 154.8 μT, while measured local geomagnetic-field levels ranged from 46.6 to 50.6 μT. The maximum value was observed above the Anan-Kihoku Link underground-cable section and was far below the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference level for general public exposure to static magnetic fields. Lateral-profile measurements showed that values near the lines or cable routes diminished to local geomagnetic-field levels within several tens of metres. Geomagnetic-field-aware calculations were generally consistent with representative measured profiles, although underground-cable comparisons were sensitive to cable-centreline uncertainty. These data support static magnetic-field exposure assessment around operating direct-current transmission facilities.

Related

  1. The transformative impact of stem cell core facilities in biomedical research
    Barbara Corneo, Giovanni Faga, Inês Figueira +12
    Stem Cell ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationHAL
  2. Genome-wide scan for transmission ratio distortion in trios from the Norwegian MoBa cohort rules out moderate distortion at common variants
    Shannon D’Urso, Elizabeth C. Corfield, Laurie J. Hannigan +9
    Genome BiologyPeer-reviewedCC BY 4.0Molecular biology & gene regulationGenetics & genomicsCrossref
  3. Automating Nanoparticle Analysis in Transmission Electron Microscopy with Synthetically Trained Segmentation Models
    Natalia Sá, Andrew Stewart
    ChemRxivPreprintCC BYStructural biologyChemRxiv
  4. Crossed laser phase plates for transmission electron microscopy
    Petar N. Petrov, Jessie T. Zhang, Jeremy J. Axelrod +2
    Nature CommunicationsPeer-reviewedCC BYFull text10 citedStructural biologyOpenAlex
  5. TEM Agent: enhancing transmission electron microscopy with modern AI tools
    Morgan K. Wall, Alexander J. Pattison, Edward S. Barnard +2
    npj Computational MaterialsPeer-reviewedCC BYFull text14 citedStructural biologyOpenAlex
BibTeX
@article{kawabe2026environmental,
  title = {{Environmental monitoring of static magnetic fields around operating high-voltage direct-current transmission facilities in Japan}},
  author = {Fumiaki Kawabe and Shinichi Muroya and Chiyoji Ohkubo},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  month = aug,
  doi = {10.1093/rpd/ncag089},
  url = {https://doi.org/10.1093/rpd/ncag089},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Environmental monitoring of static magnetic fields around operating high-voltage direct-current transmission facilities in Japan
AU  - Fumiaki Kawabe
AU  - Shinichi Muroya
AU  - Chiyoji Ohkubo
PY  - 2026
DA  - 2026/08/18
JO  - Radiation Protection Dosimetry
DO  - 10.1093/rpd/ncag089
UR  - https://doi.org/10.1093/rpd/ncag089
AB  - Static magnetic fields are present around high-voltage direct-current transmission facilities, but on-land environmental measurement data under actual operating conditions remain limited. This study measured three-axis magnetic flux densities at 1.0 m above ground at 38 accessible locations around all four operating direct-current transmission links in Japan, including overhead-line and underground-cable sections. Resultant magnetic flux densities ranged from 39.7 to 154.8 μT, while measured local geomagnetic-field levels ranged from 46.6 to 50.6 μT. The maximum value was observed above the Anan-Kihoku Link underground-cable section and was far below the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference level for general public exposure to static magnetic fields. Lateral-profile measurements showed that values near the lines or cable routes diminished to local geomagnetic-field levels within several tens of metres. Geomagnetic-field-aware calculations were generally consistent with representative measured profiles, although underground-cable comparisons were sensitive to cable-centreline uncertainty. These data support static magnetic-field exposure assessment around operating direct-current transmission facilities.
SN  - 0144-8420
SN  - 1742-3406
ER  -