Development of high-resolution timing technique in the past 25 years

Abstract

This paper reviews recent progress in high-resolution timing, rate capability, and aging performance of particle detectors in the context of developments over the past 25 years. It focuses on MCP, SiPM, LGAD, 3D silicon, and SiEM detectors and compares their performance with that of gaseous timing detectors. In addition, preliminary results from a simplified simulation program, Mini-TCAD, are presented, indicating that hexagonal 3D silicon cells may provide better drift-time uniformity and timing resolution than square cells.

Related

  1. Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectors
    J. N. Tang, W. H. Wu, Y. Q. Tan +4
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXivHAL
  2. Development of a phantom‐based end‐to‐end QA workflow for online adaptive radiotherapy incorporating high‐resolution 2D detector measurements
    Julian Niedling, Robert Schindhelm, Luis Cervantes +2
    Journal of Applied Clinical Medical PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  3. Super-resolution technique enabled by higher-order Bessel beams in nanoscale optical structures
    Apoorva D, M Ummal Momeen
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  4. Comprehensive study of timing resolution in plastic scintillator detectors with wavelength-shifting fiber and silicon photomultiplier readout
    Haohui Che, Guang Yang
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  5. Gravitational-Wave Sky Mapping with Pulsar Timing Arrays: The Full Earth-Pulsar Response and Resolution Operational Regimes
    S. A. Andrianov, S. M. Kopeikin
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsGravitation & general relativityarXiv
BibTeX
@misc{vavra2026development,
  title = {{Development of high-resolution timing technique in the past 25 years}},
  author = {Jerry Vavra},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.14919},
  eprint = {2610.14919},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.14919},
  note = {CC0},
}
RIS
TY  - UNPB
TI  - Development of high-resolution timing technique in the past 25 years
AU  - Jerry Vavra
PY  - 2026
DA  - 2026/10/14
PB  - arXiv
DO  - 10.48550/arxiv.2610.14919
UR  - https://arxiv.org/abs/2610.14919
AB  - This paper reviews recent progress in high-resolution timing, rate capability, and aging performance of particle detectors in the context of developments over the past 25 years. It focuses on MCP, SiPM, LGAD, 3D silicon, and SiEM detectors and compares their performance with that of gaseous timing detectors. In addition, preliminary results from a simplified simulation program, Mini-TCAD, are presented, indicating that hexagonal 3D silicon cells may provide better drift-time uniformity and timing resolution than square cells.
ER  -