Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY 4.0Journal of Cardiovascular Electrophysiology

Safety and Utility of Smartphone‐Based Heart Monitors in Pediatric Patients With Cardiovascular Implantable Electronic Devices

  1. 1Department of Pediatrics and Adolescent Medicine Princess Margaret Hospital Hong Kong China
  2. 2Department of Pediatrics and Adolescent Medicine Hong Kong Children's Hospital Hong Kong China
  3. 3Department of Pediatrics and Adolescent Medicine, School of Clinical Medicine, LKS Faculty of Medicine The University of Hong Kong Hong Kong China

Abstract

Background: Portable heart monitors enable on‐demand electrocardiogram (ECG) recordings and enhance symptom‐rhythm correlation. However, concerns have been raised regarding potential electromagnetic interference (EMI) from these monitors that may affect cardiovascular implantable electronic devices (CIEDs). The safety and clinical benefits of portable heart monitors in children and adolescents with implanted CIEDs remain to be established.

Objectives: The primary objective was to determine whether KardiaMobile 6L and Apple Watch induce EMI, impacting the function of CIEDs in pediatric patients. Secondary aims included the assessment of the accuracy of heart rate measurement and their ability to detect non‐capture events.

Methods: In this cross‐sectional study, patients aged 5 years or older with implanted CIEDs were recruited from a tertiary pediatric cardiac center. Each subject had four 30 s ECGs acquired using KardiaMobile 6L and Apple Watch. Subjects were monitored for cardiac symptoms during ECG acquisition, and CIEDs were assessed for EMI. The collected ECGs were analyzed for interpretability, accuracy of heart rate measurement, and detection of non‐capture events.

Results: Thirty‐two patients (median age 14.0 years, IQR 9.9–16.6) were recruited. No adverse clinical events were identified. No EMI was detected during ECG acquisition, regardless of patient and CIED characteristics. Ninety‐eight percent of acquired ECGs were interpretable. Both devices demonstrated excellent accuracy of heart rate measurement (ρ = 0.99) and a sensitivity of 100% for identifying ventricular non‐capture events.

Conclusions: KardiaMobile 6L and Apple Watch did not induce EMI in children and adolescents with CIEDs, enabling reliable heart rate measurement and accurate identification of ventricular non‐captures on these smartphone‐based portable heart monitors.

Related

  1. Increase in Reimbursement Does Not Necessarily Place a Financial Burden on Patients ― Background Behind the Reimbursement Revision for Remote Monitoring of Cardiac Implantable Electronic Devices in Japan ―
    Takashi Ashihara
    Circulation JournalPeer-reviewedLicence not statedFull textCardiovascular medicineJ-STAGE
  2. Changes in Remote Monitoring for Patients With Cardiac Implantable Electronic Devices After a Reimbursement Revision ― An Interrupted Time-Series Analysis ―
    Koki Takegawa, Koshiro Kanaoka, Haruka Matsuura +4
    Circulation JournalPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineJ-STAGE
  3. Cutaneous warning signs of cardiac implantable electronic device infection: a pictorial guide for clinicians
    Fawzi Kerkouri, Amine El Ouahidi, Vincent Mansourati +2
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossrefEurope PMCPMC
  4. Comparison of device-based and bioelectrical impedance methods for volume status assessment in heart failure patients with cardiac implantable electronic devices (CIED vs. BIA fluid assessment in heart failure)
    Sedat Altıntepe, Fatih Gülçebi, Ahmet Özderya +2
    Indian Pacing and Electrophysiology JournalPeer-reviewedCC BY-NC-ND 4.0Full text1 citedCardiovascular medicinePMC
  5. Enacting policy to use administrative data for surveillance of cardiac implantable electronic device infections in Alberta, Canada
    Elissa Rennert-May, Derek Chew, Madelyn Knaub +10
    Antimicrobial Stewardship & Healthcare Epidemiology : ASHEPeer-reviewedCC BY 4.0Full textInfectious diseasePMC
BibTeX
@article{ho2026safety,
  title = {{Safety and Utility of Smartphone‐Based Heart Monitors in Pediatric Patients With Cardiovascular Implantable Electronic Devices}},
  author = {Chun‐Lok Ho and Sit‐Yee Kwok and Sabrina S. L. Tsao and Yiu‐Fai Cheung},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  month = jul,
  doi = {10.1111/jce.70444},
  url = {https://doi.org/10.1111/jce.70444},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Safety and Utility of Smartphone‐Based Heart Monitors in Pediatric Patients With Cardiovascular Implantable Electronic Devices
AU  - Chun‐Lok Ho
AU  - Sit‐Yee Kwok
AU  - Sabrina S. L. Tsao
AU  - Yiu‐Fai Cheung
PY  - 2026
DA  - 2026/07/19
JO  - Journal of Cardiovascular Electrophysiology
DO  - 10.1111/jce.70444
UR  - https://doi.org/10.1111/jce.70444
AB  - Background: Portable heart monitors enable on‐demand electrocardiogram (ECG) recordings and enhance symptom‐rhythm correlation. However, concerns have been raised regarding potential electromagnetic interference (EMI) from these monitors that may affect cardiovascular implantable electronic devices (CIEDs). The safety and clinical benefits of portable heart monitors in children and adolescents with implanted CIEDs remain to be established.  Objectives: The primary objective was to determine whether KardiaMobile 6L and Apple Watch induce EMI, impacting the function of CIEDs in pediatric patients. Secondary aims included the assessment of the accuracy of heart rate measurement and their ability to detect non‐capture events.  Methods: In this cross‐sectional study, patients aged 5 years or older with implanted CIEDs were recruited from a tertiary pediatric cardiac center. Each subject had four 30 s ECGs acquired using KardiaMobile 6L and Apple Watch. Subjects were monitored for cardiac symptoms during ECG acquisition, and CIEDs were assessed for EMI. The collected ECGs were analyzed for interpretability, accuracy of heart rate measurement, and detection of non‐capture events.  Results: Thirty‐two patients (median age 14.0 years, IQR 9.9–16.6) were recruited. No adverse clinical events were identified. No EMI was detected during ECG acquisition, regardless of patient and CIED characteristics. Ninety‐eight percent of acquired ECGs were interpretable. Both devices demonstrated excellent accuracy of heart rate measurement (ρ = 0.99) and a sensitivity of 100% for identifying ventricular non‐capture events.  Conclusions: KardiaMobile 6L and Apple Watch did not induce EMI in children and adolescents with CIEDs, enabling reliable heart rate measurement and accurate identification of ventricular non‐captures on these smartphone‐based portable heart monitors.
SN  - 1045-3873
SN  - 1540-8167
ER  -